Ultrasonic Anemometer 3D
The Ultrasonic Anemometer 3D
serves for the 3-dimensional
acquisition of the horizontal
and vertical components of
the wind velocity, the wind
direction as well as of the
acoustic-virtual temperature.
More than 70 different
measurement values are
available, for ex.:
• Wind velocity in X/Y/Z-direction
• Total wind velocity
• Wind velocity azimuth
• Wind direction azimuth
• Wind velocity elevation
• Wind direction elevation
• Acoustic-virtual temperature
• Standard deviation of the
wind velocity in X/Y/Zdirection
• Standard deviation of the
total wind velocity
• Standard deviation of the
wind velocity azimuth
• Standard deviation of the
wind direction azimuth
• Standard deviation of the
wind direction elevation
• Standard deviation of the
acoustic-virtual temperature
• Statistic functions such
as variance, co-variance,
turbulence intensity
• Wind velocity X/Y/Z of the
gust acc. to WMO
• Wind direction of the gust
(elevation) acc. to WMO
The instrument is especially
suited for the use in the fields
of
• Meteorology
• Climatology
• Traffic engineering, aviation
and navigation
• Indoor flow measurement
• And in alpine field of
application
The ultrasonic measurement
principle allows, compared to
the classic anemometers, an
inertia-free measurement of
running variable dimensions
with highest precision and
accuracy. It is especially suited
for the measurement of gustand
peak values.
The measurement values can
be output digitally and/or in
analogue form.
The serial or analogue output
of the data is carried out
alternatively as instantaneous
value or with selectable time
frame.
If necessary, the sensor
arms and the middle rod are
automatically heated in case of
critical ambient temperatures.
Thanks to the additionally
installed ultrasonic converter
heating the instrument is
suited even for the difficult
application in locations
where frequently icing is to be
expected.
4.3830.2x.xxx
Wind velocity Meas. range
Resolution
Accuracy
Direction Meas. range
Azimuth
Elevation
Resolution
Accuracy
Virtual temp. Meas. range
Resolution
Accuracy
Data output
digital Interface
Baud rate
Output
Output rate
Status signal
Data output
analogue Electr. output
(for wind vectors
XYZ or wv (azimuth),
wd (azimuth) and
acoustic-virtual temp.
Load
Current output
Voltage output
or as: data input
output
dissolution
General Bus operation Operat. voltage
Electronics
with heating
Electr. connection
Housing material
Protection
Dimensions
Weight
0-65 m/s
0.1 m/s (standard)
0.01
(user-defined)
±0.1 m/s rms
(0-5 m/s)
±2% rms (< 5 m/s)
0-360°
-90°… +90°
1°
±2°
-40 … +70 °C
0.1 K
±0.5 K
RS 485/422
1200 - 921600
instantan. values,
mean values,
standard deviations,
etc.
1 per 1 msec. up to
1 per 60 sec.
heating
distance error,
distance temperat.
0-20 mA/0-10 V
or
4-20 mA/2-10 V
max. 400 Ω
min. 4000 Ω
3 x 0-10 V
serial
16 bit
up to 98 instruments
8-24 V DC or
12-28 V AC/2.5 VA
24 V AC/DC,
typ 150 VA
8 pole plug
aluminium and
stainless steel (V4A)
IP 65
600 x 300 mm
1.5 kg
Anemometer Ultrasonic 2D
The Ultrasonic Anemometer 2D
serves for the 2-dimensional
acquisition of the horizontal and
vertical components of the wind
velocity, the wind direction as
well as of the acoustic-virtual
temperature.
More than 35 different
measurement values are
available, for ex.:
• Orthogonal wind velocity
vectors (X- and Y-distance)
• Scalar wind velocity
• Wind direction
• Acoustic-virtual temperature
• Acoustic-virtual temperature of
the orthogonal measurement
distances (X- and Y-distance)
• Standard deviation of the
vectorial wind velocity
(X and Y-distance)
• Standard deviation of the
scalar wind velocity
• Standard deviation
of the wind direction
• Standard deviation of the
acoustic-virtual temperature
• Wind velocity of the gust acc.
to WMO
• Wind direction of the gust acc.
to WMO
The instrument is especially
suited for the use in the fields of
• Meteorology
• Climatology
• Regenerative energy, wind
energy plant
• Traffic engineering, aviation
and navigation
• Pollutant dispersal
• Wind alarm devices, building
construction and building
safety
• Indoor flow measurement
• And in alpine field of
application
The ultrasonic measurement
principle allows, compared to
the classic anemometers, an
inertia-free measurement of
running variable dimensions
with highest precision and
accuracy. It is especially suited
for the measurement of gustand
peak values.
The measurement values can
be output digitally and/or in
analogue form.
The serial or analogue output
of the data is carried out
alternatively as instantaneous
value or with selectable time
frame.
If necessary, the sensor arms
are automatically heated
in case of critical ambient
temperatures. The possibility
of malfunction, caused by
icing, is minimized.
Model no. 4.3820.3x.xxx,
thanks to the additionally
installed ultrasonic converter
heating, is suited even for the
more difficult use in locations
where frequently icing is to be
expected.
4.3820.xx.xxx .0x. .3x.
With heating
With heating
Velocity
Measuring range
Resolution
Accuracy
Direction
Measuring range
Azimuth
Resolution
Accuracy
Virtual temperature
Measuring range
Resolution
Accuracy
Data output digital
Interface
Baud rate
Output
Output rate
Status signal
Data output analogue
Electr. output
for wv, wr, acoustic-
virtual temperature
Load
Current output
Voltage output or as:
data input
output resolution
General
Bus operation
Operat. voltage
Electronics
with heating
Electr. connection
Housing material
Protection
Dimensions
Weight
For sensor arms
For sensor arms and
ultrasonic-sensors
0-75 m/s
0.1 m/s (standard)
0.01
(user-defined)
±0.1 m/s rms
(0-5 m/s)
±2% rms (< 5 m/s)
0-360°
-90° …. +90°
1°
±2°
-40 … +70 °C
0.1 K
±0.5 K
RS 485/422
1200-921600
instantan. values,
mean values,
standard deviations,
etc.
1 per 1 msec. up to
1 per 60 sec.
heating
distance error,
distance temperat.
0-20 mA/0-10 V or
4-20 mA/2-10 V
max. 400 Ω
min. 4000 Ω
3 x 0-10 V
serial
16 bit
up to 99 instruments
8-24 V DC or
12-28 V AC/2.5 VA
24 V AC/DC,
typ. 80 VA
8 pole plug
aluminium and
stainless steel (V4A)
IP 65
600 x 300 mm
2.5 kg
Accessories
Device to Refuse Birds
The device protects the ultrasonic converter of the ultrasonic anemometer (4.3820.xx.xxx).
The device shall prevent saller birds from sitting on the instrument.
507245
Device to Refuse Birds
• consisting of:
• Pin and
• protective cap
A pin to be screwed onto the shaft, shall protect the instrument against bigger birds and prevent them from sitting on.
508396
212352
Connecting Cable
Suited for 4.3820/30........
Shielded cable, ready for connection with plug on sensor and cable end sleeve on the other end.
507751
507752
507753
507754
507755
Cable length
15 m
20 m
25 m
30 m
40 m
Software Meteo-Online
9.1700.98.000
s. page 46
Ultrasonic Anemometer compact
The Ultrasonic Anemometer compact
serves for the 2-dimensional
acquisition of the horizontal components
of the wind velocity, the
wind direction and the acoustic-
virtual temperature.
The following measuring
values are available:
• Orthogonal wind velocity
vectors (X- and Y-distance)
• Scalar / vectorial wind velocity
wind direction
• Acoustic-virtual temperature
• NMEA data protocol
• ASCII THIES FORMAT
• Analogue data output *
The instrument is especially
suited for the use in the fields of
• Regenerative power generation,
wind power plants
• Industrie automation
• Wind warning devices, building
construction and building
security
• Traffic engineering, aviation
and navigation
• Meteorology
• Climatology
The measurement principle
allows, compared to the classic
anemometers, an inertia-free
measurement of running
variable dimensions with highest
precision and accuracy.
The measurement values can
be output digitally and/or in
analogue form.
The serial or analogue output
of the data is carried out
alternatively
as instantaneous
value or as gliding mean value
with selectable time frame.
If necessary, the instrument is
automatically
heated in case of
critical ambient temperatures.
Thus, the possibility of
malfunction,
caused by icing,
is minimized. The sensor arms
and the ultrasonic sensors are
heated.
* only in HD (half duplex)
operation
4.387x.0x.xxx
0.0x.xxx
1.0x.xxx
Mast boring
Mast boring
Velocity
Measuring range
Resolution
Accuracy
Direction
Measuring range
Azimuth
Resolutlion
Accuracy
Virtual Temp.
Measuring range
Resolution
Accuracy
Data output digital
Interface
Baud rate
Output
Output range
Status signal
Data output analogue
Electr. output
for WV, WD,
ac.- virtual temp.
Load
Current output
Voltage output
resolution
General
Bus operation
Operation voltage
Electronic
Wind Transmitter
The wind transmitters is
designed for the directionindependent
measurement of
the horizontal air-flow.
The wind transmitter is
equipped with a contact-free
opto-electronic scanner, which
causes an extremely low starting
speed. At the output the
measuring value is available
as digital signal.
The heating is electronically
controlled. A plug-connection
is situated in the shaft of the
instrument. The instrument is
mounted preferably onto a
mast or traverse. All essential
parts are made of anodised
Aluminium.
0.3-50 m/s
3-1042 Hz (live zero)
3-1042 Hz
(no live zero)
max. 60 m/s
5 m
±0.3 m/s/±2% of m.v.
3.3 ... 47 V DC
24 V AC/DC; 20 W
-35 ... +80°C
5-pole plug connection
7-pole plug connection
onto mast tube 1 1/2”
Ø 50 x 50 mm
Ø 315 x 230 mm
IP 55
1 kg
Wind Transmitter
This wind transmitter is
designed for high wind
velocities.
The instrument is equipped
with a reinforced cup star.
4.3303.22.0xx 008 018
Meas. range
Electr. output
Accuracy
Operating voltage
Electronics
Heating
Electr. connection
0.5-75 m/s
0-754 Hz (live zero)
0-754 Hz
(no live zero)
±0.5 m/s / ±2% of m.v.
3.3 ... 47 V DC
24 V AC/DC; 20 W
5-pole plug
connection
Wind Transmitter
The wind transmitter is
equipped with a contact-free
opto-electronic scanner.
A connected electronics
converts the speed-dependent
frequency into an analogue
output signal.
Operating voltage
Electronics
Heating
Electr. connection
0,3 ... 50 m/s
0,3 ... 60 m/s
0 ... 20 m
4 ... 20 mA
0 ... 1 V
0 ... 10 V
0 ... 5 V
± 0,4 m/s / ± 2,5%
v. Mw.
15...24 V DC
24 V AC/DC ; 20 W
5-pole plug connection
Wind Transmitter
This wind transmitter is
equipped with a DC-generator
which produces a d.c-voltage
with the rotation of the cup
star. It is able to operate a
respective display instrument
directly (without current
supply).
0.5 ... 35 m/s
0 ... 4.67 mA DC,
linear Ra = 400 Ω
max. 60 m/s
± 0.5 m/s/ ± 2% v. Mw.
24 V AC/DC; 20 W
5-pole plug connection
Wind Direction Transmitter
Wind Direction Transmitter
Measuring value transmitter
for measuring the direction
of the horizontal air flow.
Potentiometer-wind-directiontransmitters
are equipped with
a sliding potentiometer which
offers a theoretically unlimited
resolution.
The heating is electronically
controlled. A plug-connection
is situated in the shaft of the
instrument. The instrument is
mounted preferably onto a
mast or traverse. All main
parts are made of anodised
aluminium.
12 V DC, max 1.5 W
24 V AC/DC,
max. 20 W
max. 60 m/s
0.5 m/s at 90°
0.2-0.3
-35 ... +80 °C
8-pole plug
connection
onto mast tube 1 1/2"
415 mm high
IP 55
1.8 kg
Wind Direction Transmitter
Measuring value transmitter
for measuring the direction
of the horizontal air flow.
The wind direction transmitter
is equipped with a contact-free
scanning system which
causes an extremely low
starting speed, and operates
in wear-resistant manner. The
digital measuring signals are
transformed by an internal
measuring transformer.
The output is available as
analogue current- or voltage
signal.
Measuring range
Resolution
Accuracy
Load
Starting value
Damping coefficient
Operating voltage
Heating
Ambient temperature
Electr. connection
Mounting
Dimensions
Weight
0 - 20 mA
4 - 20 mA
0 - 1 V
0 - 10 V
0 - 5 V
0 - 360°
2,5°
± 2,5°
max. 60 m/s
< 0.6 m/s at 90°
0.2 ... 0,3
14 - 18 V DC
24 V AC/DC, max.20W
- 35 ... + 80 °C
5-pole plug connection
onto a mast tube
1 1/2”
415 mm high
1,8 kg
Wind Direction Transmitter
Measuring value transmitter
for measuring the direction
of the horizontal air flow.
The position of the wind vane
is detected opto-electronically
by a code disc, which causes
an extremely low starting
speed, and operates in wearresistant
manner.
The output is available as serial
or as parallel digital signal.
Measuring range
Resolution
Accuracy
Load
Starting value
Damping coefficient
Operating voltage
Electronics
Heating
Ambient temperature
Electr. connection
with xx.xxxx.000
with xx.xxxx.100
Mounting
Dimensions
Protection
Weight
8-bit parallel
8-bit serial-syn.
0-360°
2.5°
±1.5°
max. 60 m/s
< 0.6 m/s at 90°
0.2-0.3
5 / 3.5-18 V DC
24 V AC/DC, max. 20 W
-35 ... +80 °C
19-pole plug
connection
7-pole plug
connection
onto mast tube 1 1/2"
415 mm high
IP 55
1.8 kg
Combined Wind Transmitter
Combined Wind Transmitter
Measuring value transmitter for
the measurement of the wind
speed and wind direction of
the horizontal air flow.
The cup star revolution is
scanned opto-electronically in
contact-free and wear-resistant
manner. It has an extremely
low starting speed.
The position of the wind vane
is detected opto-electronically
by a code disc.
The digital measuring signals
are transformed by an internal
measuring transformer.
The output signals are available
as current or voltage signals.
The heating is controlled electronically.
A plug connection is
situated in the shaft of the
instrument. The instrument is
mounted preferably onto a mast.
All main parts are made of
anodised aluminium.
0.3-50 m/s
0.3-60 m/s
0-20 mA
4-20 mA
0-10 V
0-5 V
0-360°
±0.5 m/s or
±2.0%
of meas. value
±1.5°
max. 60 m/s
5 m
< 0.6 m/s at 90°
0.2-0.3
15-24 V DC or
24 V AC/DC,
w. heating
max. 40 W
-35 ... +80°C
multi-pole plug
Ø 50 x 50 mm
onto mast tube 1 1/2"
620 mm
IP 55
3.4 kg
Combined Wind Transmitter
Measuring value transmitter
for the measurement of the
wind speed and wind direction
of the horizontal air flow.
The cup star revolution is
scanned opto-electronically in
contact-free and wear-resistant
manner.
It has an extremely low starting
speed.
The position of the wind vane
is detected opto-electronically
by a code disc.
The output signals are
available as frequency for wind
speed, and as 8-bit-Gray-code
(parallel) for wind direction.
The ship-version is equipped
with a strengthened cup star
and a smaller wind vane.
Standard land version
Ship version
0.3 ... 50 m/s
0 ... 360°
3 ... 1042 Hz
8-bit-Gray-code
(parallel)
0.05 m ; 2.5°
±0,3 m/s or
±2 % of meas. value
±1,5°
15 V DC (5 … 18 V) or
24 AC/DC, w. heating
max. 60 m/s
5 m
< 0.6 m/s at 90°
0.2 ... 0.3
max. 40 W
-35 ... +80°C
multi-pole plug
Ø 50 x 50 mm
onto mast tube 1 1/2”
620 mm
3,4 kg
Combined Wind Transmitter
Measuring value transmitter
for the measurement of the
wind speed and wind direction
of the horizontal air flow.
The cup star revolution is
scanned opto-electronically in
contact-free and wear-resistant
manner.
It has an extremely low starting
speed.
The position of the wind vane
is detected opto-electronically
by a code disc.
The output signals are
available as frequency for the
wind speed and as serialsynchronous
8-bit for wind
direction.
The ship-version is equipped
with a strengthened cup star
and a smaller wind vane.
Meas. range wv
Meas. range wd
Electr. output wv
Electr. output wd
Resolution
Accuracy
Load
Delay distance
Starting value
Damping coefficient
Operating voltage
Heating
Ambient temp.
Electr. connection
Fixing boring
Mounting
Total height
Protection
Weight
for Datalogger
Standard land version
Ship version
0.3-50 m/s
0-360°
3-1042 Hz
8-bit serial-
synchronous
0.05 m; 2.5°
±0.3 m/s oder
±2% of meas. value
±1.5°
max. 60 m/s
5 m
< 0.6 m/s at 90°
0.2-0.3
4-18 V DC
40 W, 24 V AC/DC
-35 ... +80 °C
multi-pole plug
Ø 50 x 50 mm
onto mast tube 1 1/2"
620 mm
IP 55
3.4 kg
The wind transmitter is designed for the acquisition of the horizontal component of the wind speed in the field of meteorology and environmental measuring technology, evaluation of location, and measurement of capacity characteristics of wind power systems. In the plain country the wind transmitter meets all requirements of IEC 61400.121-CD for a
1. class instrument. Special characters are a defined and
optimised, dynamic behaviour
also at high turbulence intensity,
minimal over-speeding,
and a low starting value.
The measuring value is
available at the output as
digital signal. It can be transmitted
to display instruments,
recording instruments, data
loggers as well as to process
control systems. For winter
operation the instrument is
equipped with an electronically
regulated heating, which
guarantees a smooth running
of the ball bearings, and
prevents the shaft and slot
from icing-up
4.3350.00.000 .10.
With heating
W/o heating
Measuring range
Accuracy
0.3 ... 50 m/s
50 ... 75 m/s
Linearity
Inclined flow
...mean deviation
from the cosinus
line
Turbulence effect
Electr. output
Load
Delay distance
Operating voltage
Electronics
Heating
Ambient temp.
Electr. connection
Mounting
Fixing boring
Dimensions
Protection
Weight
Material
Housing
Cup star
0.3...75 m/s
< 3% of meas. value
or < 0.3 m/s
< 6% of meas. value
r > 0.999 95 (4..20m/s)
1% (in the range ±20°)
<1% (in the range up
to 30%turbulence
intensity)
1000 Hz at 50 m/s
max. 85 m/s
< 3 m
3.3 … 42 V DC
24 V AC/DC; 25 W
-50 ..+ 80°C
8-pole plug connection
onto mast tube R 1”
Ø 35 x 25 mm
290 x 240 mm
IP 55
0.5 kg
alu, anodised
carbon-fibre-reinforced
plastic
Wind Transmitter "First Class" Advanced
• Low Power Instrument
• Digital output
The wind transmitter is
designed for the acquisition
of the horizontal component
of the wind velocity in the field
of meteorology and environmental
measuring technology,
evaluation of location, and
measurement of capacity
characteristics of wind power
systems. In the plain country
the wind transmitter meets all
requirements of
IEC 61400-12-1 for an
Instrument of the accuracy
class 0.5.
Special characters are a
defined and optimised,
dynamic behaviour also at high
turbulence intensity, minimal
over-speeding, and a low
starting value.
The measuring value is
available at the output as
digital signal. It can be transmitted
to display instruments,
recording instruments, data
loggers as well as to process
control systems.
For winter operation the
instrument (4-3351.00.000) is
equipped with an electronically
regulated heating, which
guarantees a smooth running
of the ball bearings, and
prevents the shaft and slot
from icing-up.
4.3351.00.000 .10.
With heating
W/o heating
Measuring range
Accuracy
0.3 ... 50 m/s
Linearity
Inclined flow
- mean deviation
from the cosinus
line
- Turbulence effect
Electr. output
Delay distance
Survival speed
Operating voltage
Electronics
Heating
Ambient temp.
Electr. connection
Mounting
Fixing boring
Dimensions
Protection
Weight
Material
Housing
Cup star
0.3 ... 75 m/s
< 2% of meas. value
or < 0.2 m/s
r > 0.999 95
(4 ... 20 m/s)
< 0.1%
(in the range ±20°)
< 1% (in the range up
to 30% turbulence
intensity)
1080 Hz @ 50 m/s
< 3 m
80 m/s
(max. 30 minutes)
3.3 … 42 V DC
0.3 mA with 3.3 V
< 0,5 mA with 5 V
24 V AC/DC; 25 W
-50 ... +80 °C
8-pole plug
connection
onto mast tube R 1"
Ø 35 x 25 mm
290 x 240 mm
IP 55
0.5 kg
alu, anodised
carbon-fibrereinforced
plastic
Wind Transmitter
“First Class” Advanced
• Analog output and
• Digital output
The wind transmitter is
designed for the acquisition
of the horizontal component
of the wind speed in the field
of meteorology and environmental
measuring technology,
evaluation of location, and
measurement of capacity
characteristics of wind power
systems. In the plain country
the wind transmitter meets
all requirements of
IEC 61400-12-1 for an accuracy
class 0.5 instrument.
Special characters are a
defined and optimised,
dynamic behaviour also at high
turbulence intensity, minimal
over-speeding, and a low
starting value.
The measuring value is
available at the output as
analogue signal and as
rectangular digital signal.
For winter operation the
instrument (4.3351.00.xxx) is
equipped with an electronically
regulated heating, which
guarantees a smooth running
of the ball bearings, and
prevents the shaft and slot
from icing-up.
4.3351.00.xxx
.10.xxx
.x0.140
.x0.141
.x0.161
With heating
W/o heating
Electr. output
Analogue
Digital
Sink output
Source output
Electr. output
Analogue
Digital
Sink output
Source output
Electr. Output
Analogue
Digital
Sink output
Source output
General
Measuring range
Accuracy
0.3-50 m/s
Linearity
Survival speed
Distance constant
Operating voltage
Electronics
Heating
Ambient temperature
Electr. connection
Mounting
Fixing boring
Weight
Material
Housing
Cup star
0-20 mA
(0.3-75 m/s)
1000 Hz at 50 m/s
1 max 250 mA
1 max 100 mA
4-20 mA
(0.3-75 m/s)
1000 Hz at 50 m/s
1 max 250 mA
1 max 100 mA
0-10 VDC
(0.3-75 m/s)
1000 Hz @ 50 m/s
1 max 250 mA
1 max 100 mA
0.3-75 m/s
< 2% of meas. range
Or < 0.2 m/s
> 0.99995 (4-20 m/s)
85 m/s
(min. 30 minutes)
< 3 m
15-24 V DC
24 V AC/DC; 25 W
-50 … +80 °C
8-pole plug
connection
Onto mast tube R 1"
Ø 35 x 25 mm
0.5 kg
Alu, anodised
carbon-fibrereinforced
plastic
Wind Direction Transmitter
Wind Direction Transmitter "First Class"
• Low Power Instrument
With digital output
(Thies serial-synchronous)
The wind transmitter is designed
for the acquisition of the
horizontal component of the
wind direction in the field of
meteorology and environmental
measuring technology,
evaluation of location, and
measurement of capacity
characteristics of wind power
systems.
Special characters are a
defined and optimised,
dynamic behaviour as well as:
• High measurement accuracy
and resolution
• High damping with small
distance constant
• Low starting value
• Low power consumption
• Simple mounting
The measuring value is
available at the output as
digital signal. The output
signal can be transmitted to
display instruments, recording
instruments, data loggers
as well as to process control
systems.
For winter operation the
instrument (4.3150.00.xxx)
is equipped with an
electronically regulated heating.
4.3150.00.00x .10.00x
.x0.000
.x0.001
With heating
W/o heating
Measuring range
Accuracy
Electr. output
Resolution
Electr. output
Resolution
Operating voltage
Electronics
Current consumption
Heating
Ambient temp.
Starting value
Distance constant
Damping ratio
Electr. connection
Mounting
Fixing boring
Dimensions
Protection
Weight
Material
0-360°
1° (0.5°)
8 bit serial-synchron
2.5°
10 bit serial-synchron
0.35°
3.3-42 V DC
1.4 mA. standby
24 V AC/DC; 25 W
-50 ... +80 °C
< 0.5 m/s at 10°
< 1 m (acc. to
ASTM D 5366-96)
D > 0.25
8-pole plug
connection
Onto mast tube R 1"
Ø 35 x 25 mm
390 x 240 mm
IP 55
0.7 kg
Alu, anodised
Wind Direction Transmitter "First Class"
• Digital output RS 485
The wind transmitter is designed
for the acquisition of the
horizontal component of the
wind direction in the field of
meteorology and environmental
measuring technology, evaluation
of location, and measurement
of capacity characteristics
of wind power systems. Special
characters are a defined and
optimised, dynamic behaviour
as well as:
• High measurement accuracy
and resolution
• High damping with small
distance constant
• Low starting value
• Low power consumption
• Simple mounting
The measuring value is available
at the output as digital signal.
The output signal can be transmitted
to display instruments,
recording instruments, data
loggers as well as to process
control systems.
For winter operation the
instrument (4.3150.00.xxx)
is equipped with an
electronically regulated heating.
Operating voltage
Electronic
Current consumption
Heating
Ambient temperature
Starting value
Distance constant
Damping ratio
Electr. connection
Mounting
Fixing boring
Dimensions
Protection
Weight
Material
0-360°
1°
0.01° @ 12 bit
serial data flow
RS 485
1200-57600 baud
xxx.xx for ex. 075.36°
3.3-42 V DC
approx. 6 mA
24 V AC/DC; 25 W
-50 ... +80 °C
< 0.5 m/s at 10°
< 1 m (acc. to
ASTM D 5366-96)
D ≤ 0.25
8-pole plug
connection
onto a mast tube R 1"
Ø 35 x 25 mm
390 x 240 mm
IP 55
0.7 kg
Alu, anodised
Wind Direction Transmitter "First Class"
• Analogue output
The wind transmitter is designed
for the acquisition of the
horizontal component of the
wind direction in the field of
meteorology and environmental
measuring technology, evaluation
of location, and measurement
of capacity characteristics
of wind power systems. Special
characters are a defined and
optimised, dynamic behaviour
as well as:
• High measurement accuracy
and resolution
• High damping with small
distance constant
• Low starting value
• Low power consumption
• Simple mounting
The measuring value is
available at the output as
analogue signal. The output
signal can be transmitted to
display instruments, recording
instruments, data loggers as well
as to process control systems.
For winter operation the
instrument (4.3150.00.xxx)
is equipped with an electronically
regulated heating.
4.3150.00.xxx
.10.xxx
.x0.140
.x0.141
.x0.161
With heating
W/o heating
Measuring range
Accuracy
Resolution
Electr. output
Operating voltage
Electronics
Current consumption
Electr. output
Operating voltage
Electronics
Current consumption
Electr. output
Operating voltage
Electronics
Current consumption
Heating
Ambient temperature
Starting value
Distance constant
Damping degree
Electr. connection
Mounting
Fixing boring
Dimensions
Protection
Weight
Material
0-360°
1°
0.35°
0-20 mA
15-24 V DC
approx. 4.5 mA + Iout
4-20 mA
15-24 V DC
approx. 4.5 mA + Iout
0-10 V
15-24 V DC
approx. 4.5 mA
24 V AC/DC; 25 W
-50 ... +80 °C
< 0.5 m/s at 10°
< 1 m (acc. to
ASTM D 5366-96)
D > 0.25
8-pole plug
connection
onto a mast tube R 1"
Ø 35 x 25 mm
390 x 240 mm
IP 55
0.7 kg
Alu, anodised
Wind Direction Transmitter "First Class"
• Potentiometer output
with protective circuit
The wind transmitter is designed
for the acquisition of the
horizontal component of the
wind direction in the field of
meteorology and environmental
measuring technology, evaluation
of location, and measurement
of capacity characteristics
of wind power systems.
Special characters are a defined
and optimised, dynamic
behaviour as well as:
• High measurement accuracy
and resolution
• High damping with small
distance constant
• Low starting value
• Hysteresis-free and non-wearing
magnetic coupling
between vane- and
potentiometer-axis
• Electronic protective circuit
for current limiting and
against erroneous connection
• Simple mounting
The measuring value is
available at the output as
analogue signal. The output
signal can be transmitted
to display instruments, recording
instruments, data loggers
as well as to process control
systems.
The electronic protective circuit
prevents the potentiometer
from overloading in case of
erroneous connection and on
transition from 0° to 360°. The
protective circuit represents
a multiplier of 50 Ω, however
limits the short cut current on
transition from 0° to 360° (and
vice-versa) to 1 mA at 10 k Ω
Potentiometer and 2 mA
with a 2 k Ω potentiometer.
For winter operation the
instrument (4.3150.00.xxx)
is equipped with an electronically
regulated heating.
4.3150.00.x1x
.10.x1x
.x0.110
.x0.012
With heating
W/o heating
Measuring range
Accuracy
Electr. output
Multiplier
Operating voltage
Potent./electronics
Current consumption
Electr. output
Operating voltage
Potent./electronics
Current consumption
Heating
Ambient temp.
Starting value
Distance constant
Damping ratio
Electr. connection
Mounting
Fixing boring
Dimensions
Protection
Weight
Material
0-360°
< 1.5°
Potentiometer 10 KΩ
50 Ω
4-42 V DC ≤ Us / 10 kΩ
Potentiometer 2 KΩ
4-42 V DC ≤ Us / 2 kΩ
24 V AC/DC; 25 W
-50 ... +80 °C
< 0.5 m/s at 10°
< 1 m (acc. to
ASTM D 5366-96)
D > 0.25
8-pole plug
connection
onto a mast tube R 1"
Ø 35 x 25 mm
390 x 240 mm
IP 55
0.7 kg
Alu, anodised
Wind Direction Transmitter "First Class"
• Potentiometer output
The wind transmitter is designed
for the acquisition of the
horizontal component of the
wind direction in the field of
meteorology and environmental
measuring technology,
evaluation of location, and
measurement of capacity
characteristics of wind power
systems.
Special characters are a defined
and optimised, dynamic
behaviour as well as:
• High measurement accuracy
and resolution
• High damping with small
distance constant
• Low starting value
• Hysteresis-free and nonwearing
magnetic coupling
between vane- and
potentiometer-axis
• Electronic protective circuit for
current limiting and against
erroneous connection
• Simple mounting
The measuring value is
available at the output as
analogue signal. The output
signal can be transmitted
to display instruments, recording
instruments, data loggers
as well as to process control
systems.
For winter operation the
instrument (4.3150.00.xxx) is
equipped with an electronically
regulated heating.
4.3150.00.212
.10.212
With heating
W/o heating
Measuring range
Accuracy
Electr. output
Operating voltage
Potent./electronics
Current consumption
Heating
Ambient temp.
Starting value
Distance constant
Damping ratio
Electr. connection
Mounting
Fixing boring
Dimensions
Protection
Weight
Material
0-360°
< 1.5°
Potentiometer 2 KΩ
0-30 V DC ≤ Us / 2 kΩ
24 V AC/DC; 25 W
-50 ... +80 °C
< 0.5 m/s at 10°
< 1 m (acc. to
ASTM D 5366-96)
D > 0.25
8-pole plug
connection
onto a mast tube R 1"
Ø 35 x 25 mm
390 x 240 mm
IP 55
0.7 kg
Alu, anodised
Wind Transmitter compact
Measuring transmitter for the
measurement of the horizontal
wind speed with digital output
signal (open collector).
The cup-star consists of
plastic, the housing is made
of anodised aluminium and
plastic.
The instrument has a threaded
pin PG 21 with 2 nuts for
mounting.
With heating
With heating
W/o heating
Measuring range
Accuracy
Resolution
Electr. output
Operating voltage
Current supply
Heating
Ambient temp.
Connection
Dimensions
Protection
Weight
open collector sink
open collector source
open collector source
0.5-50 m/s
±3% of meas. value
or ±0.5 m/s
< 0.1 m/s
2-573 Hz
10-28 V DC
20 mA
max. 20 W;
24 V AC/DC
-40 ... +70 °C
5 m cable. LiYCY
5 x 0.25 mm2
Ø 135 x 165 mm
IP 55
0.4 kg
Wind Transmitter compact
• Low Power Instrument
with frequency output
Measuring transmitter for the
measurement of the horizontal
wind velocity with frequency
output (active signal).
Suitable for data loggers.
The cup-star consists of plastic,
the housing is made of anodised
aluminium and plastic.
The instrument has a threaded
pin PG 21 with 2 nuts for
mounting.
Resolution
Electr. output
Operating voltage
Current consumpt.
Heating
Ambient temp.
Cable
Dimensions
Protection
Weight
0.5-50 m/s
±3% of meas. value
or ±0.5 m/s
< 0.1 m/s
2-630 Hz
3.3-42 V DC
< 1 mA
max. 20 W;
24 V AC/DC
-40 ... +70 °C
12 m cable. LiYCY
5 x 0.25 mm2
Ø 135 x 165 mm
IP 55
0.75 kg
Wind Transmitter compact
• Analogue output
Measuring transmitter for the
measurement of the horizontal
wind speed with analogue
output signals.
The cup-star consists of plastic,
the housing is made of anodised
aluminium and plastic.
The instrument has a threaded
pin PG 21 with 2 nuts for
mounting.
Resolution
Operating voltage
for 0-10 V output.
Current consumption
Heating
Ambient temp.
Connection
Dimensions
Protection
Weight
Load
(at with operat. volt.)
max. 500 Ω ;
(> 13 V DC)
max. 500 Ω ;
(> 13 V DC)
min. 1 k Ω
min. 1 k Ω
min. 1 k Ω
0.5-50 m/s
±3% of meas. value
or ±0.5 m/s
< 0.1 m/s
9-30 V DC or 24 V AC
13-30 V DC or 24 V AC
50 mA
max. 20 W;
24 V AC/DC
-40 ... +70 °C
12 m cable, LiYCY
6 x 0.25 mm2
Ø 135 x 165 mm
IP 55
0.75 kg
Wind Transmitter compact
• Model with plug connection
Model like 4.3518.00.000
and 4.3519.00.000/1xx
however with implemented
plug instead of connected
cable.
Connection
Dimensions
Height (with plug)
Cup star
Housing
Weight
7-pole plug
225 mm
Ø 135 mm
Ø 50 mm
0.4 kg
Wind Direction Transmitters
Wind Direction Transmitter compact
• Digital Parallel Output
Measuring transmitter for the
measurement of the horizontal
wind direction with digital
output signal (Gray-code).
The wind vane consists of
plastic, the housing is made
of anodised aluminium and
plastic.
The instrument has a threaded
pin PG 21 with 2 nuts for
mounting.
0-360°
±5°
90°; 45°; 22.5°
2; 3; 4-bit Gray-Code
Open collector
(source)
10-28 V DC
max. 20 W;
24 V AC/DC
-30 ... +70 °C
5 m cable LiYCY
6 x 0.25 mm2
220 mm
215 mm
Ø 50 mm
IP 55
0.6 kg
Wind Direction Transmitter compact
• Digital Serial Output
Measuring transmitter for the
measurement of the horizontal
wind direction with digital
output signal (Gray-code).
The wind vane consists of
plastic, the housing is made
of anodised aluminium and
plastic.
The instrument has a threaded
pin PG 21 with 2 nuts for
mounting.
0-360°
±5°
11.25°
5-bit serial-
synchronous
5-30 V DC
< 15 μA (5V)
< 200 μA (5V)
max. 20 W;
24 V AC/DC
-50 ... +70 °C
12 m cable, LiYCY
6 x 0.25 mm2
220 mm
215 mm
Ø 50 mm
IP 55
1.1 kg
Wind Direction Transmitter compact
• Analogue Output
Measuring transmitter for the
measurement of the horizontal
wind direction with analogue
output signals.
The wind vane consists of
plastic, the housing is made
of anodised aluminium and
plastic.
The instrument has a threaded
pin PG 21 with 2 nuts for
mounting.
Wind Direction Transmitter compact
• Analogue Output
Measuring transmitter for the
measurement of the horizontal
wind direction with analogue
output signals.
The wind vane consists of
plastic, the housing is made
of anodised aluminium and
plastic.
The instrument has a threaded
pin PG 21 with 2 nuts for
mounting.
4.3129.60.xxx
.140
.141
.161
.167
.173
Electr. output
0-20 mA
4-20 mA
0-10 V
0-2 V
0-5 V
Measuring range
Resolution
Accuracy
Operating voltage
for 0-10 V-output
Heating
Small Wind Transmitter
Measuring instrument for
the direction-independent
measurement of the horizontal
air flow in the open.
The sensor is a small construction
with a DC-generator, which
is moved by the revolution of
the cup-star.
The transmitter is made of
synthetic material
0.5 ... 35 m/s
± 5% of meas.range
or ± 0.5 m/s
0 ... 1 mA DC
Ra = 800 Ω
max. 60 m/s
Ø 35 x 35 mm
onto a mast tube 1"
-25 ... +60°C, ice-free
20 m, LiYY
2 x 0.25 mm2
Ø 134 x 175 mm
IP 54
0.3 kg
Small Wind Transmitter
Measuring instrument for the
direction-independent measurement
of the horizontal air
flow in the open.
The sensor is a small construction
with a Reed-contact,
which is activated by the
revolution of the cup-star.
The transmitter is made of
synthetic material
0.5-40 m/s
±0.5 m/s or
±5% of meas. value
50 Hz at 40 m/s
0.8 m wind run
max. 60 m/s
Reed-contact
max. 24V DC
0.5W; 100 Ω
Ø 35 x 35 mm
onto a mast tube 1"
-25 ... +60 °C, ice-free
20 m;
LiYY 2 x 0.25 mm2
Ø 134 x 175 mm
IP 54
0.3 kg
Small Wind Transmitter
Measuring instrument for the
direction-independent measurement
of the horizontal air
flow in the open.
The sensor is a small construction
with a Reed-contact,
which is activated by the
revolution of the cup-star.
The housing is made of
synthetic material.
white
black
0-100 Hz
0-10 V
0.8-40 m/s
±0.5 m/s or ±5%
of meas. range
0.4 m wind run (.x00)
max. 60 m/s
10 VA, max. 42 VDC
max. 0.4 A
Ø 35 x 35 mm
on mounting angle
-25 ... +60 °C
3 m; LiYY 4 x 0.5 mm2
resp. 2 x 0.5 mm2
Ø 134 x 160 mm
IP 54
0.3 kg
Small Wind Transmitters are ideal measuring transmitters
with best price/performance-ratio for standard requirements.
Applications: Control technique Building control system
Wind Direction Transmitters
Wind Direction Transmitter
Measuring sensor for the
measurement of the horizontal
wind direction in the open.
The instrument is a small construction
with a potentiometer
or Reed-contact, which are
activated in correspondence to
the position of the wind vane.
The instrument is made of
synthetic material.
Electr. output
Resolution
Accuracy
Measuring range
Potentiometer load
Contact load
Load
Ambient temp.
Cable
Mounting
Dimension
Protection
Weight
0-400 Ω (358°)
0.5°, 5-lead circuit
8 Reed contacts
22.5°
±4°
0-358°/0-360°
max. 100 mA,
24 V, 2.5 W
0.5 W, max. 60 V DC
max. 60 m/s
-25 ... +60 °C, ice-free
20 m, LiYCY
5 x 0.25 mm2
or 9 x 0.14 mm2
onto a mast tube 1"
210 mm high
IP 54
0.55 kg
Wind Direction Transmitter
Measuring transmitter for the
measurement of the horizontal
wind direction. The measuring
values are output as ohmic
resistance-signals. The wind
direction is detected by a wind
vane, and is then transmitted
to a potentiometer.
The outer parts of the instrument
are made of corrosionresistant
materials (plastic).
Labyrinth gaskets protect the
parts inside the instrument
against humidity.
Responsiveness
Potentiometer load
Ambient temperature
Electr. connection
Dimensions
Protection
Weight
10°-350°
(20° dead-zone
in the north)
Potentiometer
0-1 KΩ (±3%)
1 m/s
max. 1.5 W
-25 ... +60 °C, ice-free
3 m cable
210 mm high
IP 54
0.3 kg
Combined Transmitter
Measuring transmitter for the
measurement of wind velocity,
wind direction and air temperature.
Compact wind transmitter
contruction for simple
instrument mounting.
Wind vane, cup star and
housing consist partially of
fibre-reinforced plastic, housing
brackets and mast boring of
stainless steel and alu.
Ultrasonic Anemometer 1D
The Ultrasonic Anemometer
1 D serves for the measurement
of the horizontal air flow
of a fixed flow direction and the
acoustic-virtual temperature.
Different measuring values are
available, among others:
• Flow vector
• Scalar flow velocity
• Acoustic-virtual temperature
• Standard deviation
of the wind velocity
• Standard deviation
of the scalar air flow
• Standard deviation of the
acoustic-virtual temperature
• Flow velocity of the gust
The instrument is especially
suited for the use
• In the traffic engineering
• Indoor flow measurement
• In tunnels
• In tubes
The measurement principle
allows, compared to the classic
anemometers, an inertia-free
measurement of running
variable dimensions with
highest precision and accuracy.
It is especially suited for the
measurement of gust- and
peak values.
The measuring values can be
output digitally and/or in
analogue form.
The serial or analogue output
of the data is carried out
alternatively as instantaneous
value or as gliding mean value
with selectable time frame.
If necessary, the sensor arms
are automatically heated with
critical ambient temperatures.
4.3860.00.340
Flow velocity
Measuring range
Resolution
Accuracy
Flow direction
Measuring range Virtual temperature
Measuring range
Resolution
Accuracy
Data output digital
Interface
Baud rate
Output
Output rate
Status signal
Data output analogue
Electr. output
for flow,
direction and
virtual temperature
Resolution
Load
Current output
Voltage output
General
Bus operation
Operating voltage
Electronics
With heating
Electr. connection
Housing material
Protection
Dimensions
Weight
0-65 m/s
0.1 m/s
±0.1 m/s rms
(0-5 m/s)
±2% rms (> 5 m/s)
1° or 181°
-50 ... +70 °C
0.1 K
±0.5 K
RS 485 / 422
1200-921600
Instantaneous values,
Mean values,
Standard deviations
etc.
1 per 1 msec. up to
1 per 60 sec.
Heating,
Distance error
Distance temperature
0-20 mA / 0-10 V
or
4-20 mA / 2-10 V
16 bit
max. 400 Ω
min. 4000 Ω
up to 99 instruments
8-42 V DC oder
12-28 V AC/2,5 VA
24 V AC/DC,
typ. 40 VA
8-pole plug
Stainless steel (v 4 A)
IP 65
424 x 278 mm
2.5 kg
Wind Transmitter
for tunnel application
For the measurement of directional
air flows especially in
tunnels. Instrument sends
frequency signals, depending
on speed and related to the
flow direction.
Instrument is equipped with a
mounting bar.
Suitable for connection to the
Measuring Transducer TW,
order-no. 4.3348.xx.xxx
Dimension
Operating voltage
Current supply
Ambient temp.
Cable
Dimensions
Weight
0.3 ... 20 m/s
approx. 0,05 m
wind run
3.3 m
0 ... 410 Hz
resp. 418 Hz
4-blade,
polypropylene
Ø 180 mm
15 V DC (10 - 16 V DC)
approx.. 15 mA
-20 ... +70 °C, ice-free
3 m, LiYCY
4 x 0.25 mm2
Ø 200 x 350 mm
5 kg
Measuring transmitter for directional air flows.
Applications: Air Channels Shafts Climatic Ducts Street and Railway Tunnels
Wind Transmitter
for duct application
A fan wheel to determine the
directional air flow in ducts.
Mounting on a mast tube.
The fan wheel revolutions are
scanned opto-electronically by
a reflective light barrier in a
contact-free manner, thus causing
a low starting speed.
See also :
Measuring Transducer WG,
order-no.. 4.3339.xx.xxx
4.3124.30.018
4.3127.40.000
Operating voltage
Measuring range
Resolution
Electr. output
Fan wheel type
dimensions
Ambient temp.
Cable
Fixing boring
Dimensions
Weight
15 V DC /
approx. 0.3 mA
24 V DC
< 0.25 ... 20 m/s
0.083 m wind run
0 ... 240 Hz
8-blade aluminium
Ø 100 mm
-20 ... +80°C, ice-free
1 m long
Ø 37 x 20 mm
108 x 148 x 65 mm
0.9 kg
Measuring transmitter for directional air flows.
Applications: Air Channels Shafts Climatic Ducts Street and Railway Tunnels
Hand Instruments, Mech. Anemometer, Wind Measuring Systems
Cup-Anemometer
A measuring instrument
designed for hand use to take
direct wind speed readings.
Made of plastic.
4.3008.01.000
Measuring range
Dimensions
Weight
0 ... 120 km/h
0 ... 12 Beaufort
0 ... 70 kn
ø 100 x 205 mm
0.32 kg
Instrument case
(not depicted)
Transport and storage
case for the above-mentioned
anemometer.
4.3008.01.000
Material
Dimensions
Weight
wood
155 x 145 x 135 mm
1.15 kg
Digital Anemometer
The portable instrument serves
for the display of wind
velocities
The system consists of
a wind transmitter with
connected cable, a display
instrument and a transport
case.
Wind transmitter and display
instrument are made of
corrosion-free materials (alu,
plastic).
The control key is installed
in a way that the instrument
can be easily operated.
A 9 V battery for the power
supply of the system is
situated in a compartment
on the back side of the
instrument.
Wind Run Meter
Mechanical measuring instrument
for direction-independent
measurement of the horizontal
air flow and display of the wind
run. The display count cumulatively
the wind run.
Instrument is mounted on the
top of a mast.
All main parts are made of anodised
or varnished aluminium
Counting range
Resolution
Digit height
Inclination of counter
Operating range
Load
Delay distance
Ambient temp.
Mounting
Fixing boring
Dimensions
Weight
0 ... 999 999.9 km
100 m wind run
7 mm
50 °
0.5 - 60 m/s
max. 60 m/s
5 m
- 35 ... + 80 °C
onto a mast tube 1 1/2”
acc.to DIN 2441
ø 50 x 50 mm
318 x 260 mm
1.3 kg
Mechanical Wind Recorder
A mechanical instrument
designed to measure and
record wind run and direction.
A reading rule to determine
both instantaneous and mean
wind speed values is included
in the shipment.
The paper transport is carried
out by a band mechanism with
spring wound drive.
Scale division
Recording width ws
wd
Period of registration
Paper advance
Operating range
Ambient temp.
Mounting
Dimensions
Weight
0 ... 10 km wind run
0 ... 360°
1 km ; 30°
50 mm = 10 km
36 mm = 360°
31 days
10 mm/h.
0,5 ... 60 m/s
- 35 ... + 60 °C
onto a mast tube,
ø 48 mm
155 x 200 x 725 mm
10.5 kg
Recording Roll
(not depicted)
Wax coated paper for abovementioned
wind recorder.
205242
Paper length
Width of roll
sufficient for 31 days
120 mm
Instrument case
(not depicted)
For a safe transport of the
above instrument to varying
measuring places.
4.3905.20.000
Material
Dimensions
Weight
wood, unvarnished
710 x 320 x 290 mm
12.5 kg
Wind Direction Measuring Instrument
Simple portable instrument,
consisting of a mechanical
wind vane, and a telescopic
tripod stand.
There is a built-in compass to
align the instrument to "North".
Supplied in a carrying case
Measuring range
Division
Alignment
Stand, telescopic
Dim. of case
Weight
0 ... 360°
10° and N-NW-W ...N
by compass
28 to 115 cm
395 x 285 x 120 mm
1 kg
METEO comp
Complete measuring instrument,
ready for connection,
consisting of the following
components:
Measuring value
wind direction
wind speed
temperature
wind-chill
min.- and max.-values
of the past 24 h.
Comb. Wind Transmitter
Small combined measuring
transmitter for acquisition of
the wind speed and wind direction
as well as of the ambient
temperature.
4.3329.00.000
Operating voltage
Ambient temp.
Cable
Mounting
Dimensions
Weight
from display unit
-30 ... + 60 °C
20 m long, with plug
on pin ø 30 mm
200 x 450 mm
1 kg
Display Instrument
Digital LED-indicator inclusive
power supply unit, with plug
for the display of the abovementioned
measuring values.
The changing-over to the
single values is carried out
via keypad.
Plug-connection of wind
sensor, power supply unit
and serial data output.
Housing is suited for wall
mounting.
9.3229.00.000
Display ws
Resolution
Display wd
Resolution
Display temp.
Resolution
Electr. output
Operating voltage
Ambient temp.
Dimensions
Display
Power supply unit
Weight
m/s ; km/h ; Bft
0.1 m/s ; 1 km/h ;
1 Bft
0 ... 360°
22.5°
-30 ... + 60 °C
-22 ... + 140 °F
0.1 K ; 0.1 °F
RS 232/V.24, serial
9 V DC / max. 500 mA
-30 ... + 60 °C, ice-free
95 x 155 x 35 mm
65 x 100 x 55 mm
0.23 kg; 0.51 kg
The Clima Sensor D serves
for the measurement of
environmental data. These
are available as
• Serial RS 485/422
telegram and as
• analogue outputs
for further processing
The CLIMA Sensor D has
an internal DCF77 receiver,
which takes the time signal
of an atomic clock, and
integrates it into the data
telegram.
Ranges of application are:
• Building control systems
• Control technique
• Green house technique
• Processing of the acquired
data to recording or display
instruments
Depending on the model, the
following data can be
measured by the Clima
Sensor D:
• Wind velocity
• Precipitation (yes/no)
• Brightness in Eastern,
Southern and Western
direction
• Twilight
• Temperature
• Rel. humidity
The respective holder serves
for the mounting at masts
or plane surfaces, depending
on the range of application.
16-28 VDC or 24 V AC ≤ 150 mA w/o condensation
shield,
approx. 600 mA with
condensation shield
-40 °C … +60 °C
10 m calbe; LiYCY
16 x 0.14 mm2,
UV-resistant
retaining clamp,
stainless steel
Max. 1.5 kg
Ø 130 x 430 mm
Ø 130 x 430 mm
Ø 130 x 430 mm
Ø 130 x 430 mm
The speed-dependent frequency
generated by the wind
transmitters is converted into a
current or voltage signal. This
allows the control of connected
recording, display or switching
devices.
Measuring value
Operating voltage
Ambient temp.
Protection
Dimensions
Wall mount. case
PC-board
Weight
Wall mount. case
PC-board
Measuring range
0 ... 20 m/s
0 ... 40/50/75 m/s
wall mounting case
pc-board
0 - 20 mA
(max. 600 Ω)
4 - 20 mA
(max. 600 Ω)
0 - 1 V (max. 10 mA)
0 - 10 V (max. 10 mA)
0 - 20 mA / 0 - 1 V
0 - 20 mA / 0 - 10 V
4 - 20 mA / 0 - 1 V
4 - 20 mA / 0 - 10 V
instantaneous value
230 V / 50 Hz
0 ... +40°C
IP 65
(wall mounting case)
200 x 120 x 75 mm
170 x 100 x 30 mm
0.65 kg
0.25 kg
Measuring Transformer WSM
Mean value
The speed-dependent frequency
generated by the wind
transmitters is totalled up over
the selected integration time
and, as a mean value, converted
into a current or voltage
signal. This allows the control
of connected recording, display
or switching devices.
Suitable for the wind transmitters
of the classic-line with
frequency output
4.3303.22.000 / 007
4.3303.22.008 / 018
4.3341.xx.xxx .00... .10... .040
.041
.060 .061 .080 .081 .100 .101
Model
Electr. output
Electr. input
Measuring value
Measuring range
Time of integration
Operating voltage
Ambient temp.
Protection
Dimensions
Wall mount. case
PC-board
Weight
Wall mount. case
PC-board
Wall mounting case
PC-board
0 - 20 mA
(max. 600 Ω)
4 - 20 mA
(max. 600 Ω)
0 - 1 V (max. 10 mA)
0 - 10 V (max. 10 mA)
0 - 20 mA / 0 - 1 V
0 - 20 mA / 0 - 10 V
4 - 20 mA / 0 - 1 V
4 - 20 mA / 0 - 10 V
0 ... 1042 Hz (50 m/s)
mean value
selectable in 5 m/ssteps
up to 50 m/s
2.5/ 5 / 10 / 15 /
30 / 60 / 120 min,
selectable
230 V / 50 Hz
0 ... +40°C
IP 65
(wall mounting case)
200 x 120 x 75 mm
170 x 100 x 30 mm
0.7 kg
0.3 kg
Digital-Analog-Transducer TW
Mean value
The pulses from wind sensor
4.3308.10.000 are converted
by the measuring transducer
into standardized analogue
output signals.
These output signals are
available
1. as direction-dependent or
2. as direction-independent
value.
Moreover, the following settings
can be effected through
the coding switch:
Measuring range adaptation Delays for analogue signals Relay-output delay for dampening
of switching processes
in case of short-time
flow-turbulence.
The wind interface transforms
the digital signals of the wind
speed- and wind direction
transmitters into serial data
telegrams. The interface allows
the connection to different
instruments, thanks to the
interface variants available and
the possibilities of forming the
data telegram.
The voltage supply of the wind
transmitter is effected via the
wind interface. The housing is
made of aluminium, and is suited
for outside mounting.
The Clima Sensor 2000 serves
for the measurement of
important environmental data.
Depending on the type of task
it is available as combined
measuring instrument.
The analogue outputs are
configured as standard signals
so that they can be used for
the coupling on customary bus
systems.
Wind
A cup star, the revolution-no.
of which is linear-proportional
to the wind speed, supplies
a frequency through a Reedcontact
to a connected
frequency-voltage-converter.
Precipitation
The detection is carried out
optically acc. to the reflectionmethod
with modulated
infrared-light on precipitation
particles.
Brightness
The brightness is detected by
means of three independent
photo-diodes which are arranged
in 90°-segments. Three
independent output voltages
are linear to the brightness.
Twilight
The twilight is detected by
a photo diode. A converter
transforms the signal into an
output voltage, which is linear
to the twilight range.
Temperature
The temperature sensor is
a standardized resistance
thermometer - Pt 100 - of
longterm stability.
Air humidity
The measurement is carried
out with a capacitive humidity
sensor changing its capacity
according to the relative
humidity.
4.9010.00.061
4.9000.00.061
4.9011.00.061
4.9001.00.061
Wind Speed
Precipitation-
Detection
Brightness
Detection
Twilight
Temperature
Humidity
General
Wind
Precipitation,
Brightness, Twilight
Temperature Air humidity
X
X
X
X
X
X
X
X
Meas. range
Accuracy
Electr. output
Load resistor
1 … 40 m/s
≤0.5 m/s
0 … 10 V (=0 ... 40 m/s)
≥10 kΩ
Meas. range
Electr... output
Sensitivity
Load resistor
Sensitivity
Switch off-delay
Precipitation yes/no
0 V at precipitation
10 V no precipitation
Drizzle
≥100 kΩ
Drizzle
approx. 2 min.
Meas. range
Spectral range
Accuracy
Electrical output
Load resistor
0 … 100 k Lux
700 … 1050 nm
±10% of meas. value
3 x 0 … 10 V,
Eastern, Southern
and Western Direction
≥10 kΩ
Meas. range
Electr. output
Load resistor
0 … 250 Lux
0 … 10 V
≥10 kΩ
Meas. range
Meas. element
Accuracy
Electr. output
Load resistor
-20 … +60 °C
Pt100 at IEC 751 1/3 DIN
±0.15 °C at 0 °C
0 … 10 V
≥10 kΩ
Meas. range
Accuracy
Electrical output
Load resistor
0 … 100% rel. humidity
±3% in the range
10 … 90% rel. h.
0 … 10 V
≥ 10 kΩ
Operating voltage
Current load
Temperature range
Connecting cable
Mounting
Weight
24 V AC ±15%
24 V DC ±25%
≤ 150 mA
-40 °C … +60 °C
10 m; LiYCY
12 x 0.14 mm2,
UV-resistant max.
100-m supply at with
nominal 24 V
Niro-holder clamp
on mast or wall
max. 1.5 kg
Combined Clima Sensors D
Clima Sensor D
WTF
Clima Sensor D
W
Clima Sensor D
TF
Clima Sensor D
The Clima Sensor D serves
for the measurement of
important environmental
data. Depending on the task,
it is available as combined
measuring instrument. Model
D is equipped in addition
with a DCF 7 radio controlled
clock, and an integrated serial
interface. An internal heating
serves as protection against
dew.
The instrument has
• Analogue outputs and
• Serial interface
• DCF77-receiver for
date and time
• Dew protection
The analogue outputs are standard
signals and can be used
for the connection to commercially
available bus systems.
Further description see
Clima Sensor
4.9110.00.061
4.9110.00.061
4.9111.00.061
4.9101.00.061
Wind
Precipitation
Brightness
for East, South,
West
Twilight
Temperature
Air humidity
Output
analogue
serial
General
Wind
Precipitation,
Brightness, Twilight
Temperature Air humidity
X
X
X
X
X
X
X
X
Measuring range
Accuracy
Measuring range
Sensitivity
Switch-off-delay.
Load resistance
Measuring range
Spectral range
Accuracy
Measuring range
Measuring range
Accuracy
Measuring range
Accuracy
Signal
Type
Output
Measuring values
Output rate
Operating voltage
Current
consumption
Ambient temp.
Connecting calbe
Mounting
Weight
0,5 ... 40 m/s
±0,5 m/s or ±5% Mb
rain yes / no
drizzle
approx. 2 minutes
≥ 100 kW
0 ... 100 k Lux
700 ... 1050 nm
±10% of measuring
value
0 ... 250 Lux
-20 ... +60 °C
1/3 class B acc.
to IEC 751
±0.1 °C at 0 °C
0 ... 100% rel. humidity
±3 in the range
10 ... 90% rel. h.
0 ... 10 V each
parameter 0 V for rain,
10 V with dryness
Load resistance
≥ 10 kW (≥ 100 kW
with precipitation)
RS 422/485
9600Bd, 8N1, simplex-,
half-duplex-operation
Instant. values,
date and time
1 / sec.
24 V AC ±15%
24 V DC ±25%
≤ 150 mA
(with heating < 650 mA)
-40 °C ... +60 °C
10 m; LiYCY 16 x
0.14 mm2, uv-resistant
max. 100 m at supply
with nominal 24 V
non-corrosive holding
clamp for mast or wall
max. 1.5 kg
Flat-section indicator for the
display of wind speed values.
The background of the indicator
is black to facilitate reading of
the red digits.
Preferably switch panel or front
panel mounting
4.1044.00.xxx .000 .040 .041 .061
Electr. Input
Display range
Resolution
Display
Operating voltage
Model
Protection
Dimensions
Weight
0 ... 834 Hz
0 ... 20 mA
4 ... 20 mA
0 ... + 10 V
0 ... 40.0 m/s , or
depending on sensor
type
± 1 digit
LED, red, 13 mm high
230 V / 50 Hz
switch panel mounting
IP 20
96 x 48 x 104 mm
0.3 kg.
Digital Indicator WG
for panel mounting
with 2 adjustable limit contacts
Flat-section indicator for the
display of wind speed values.
Two setting knobs on the front
panel serve for setting the two
potential-free relay-contacts.
LED-digits show the switching
functions.
The background of the indicator
is black to facilitate reading of
the red digits.
Preferably switch panel or front
panel mounting.
4.1045.00.xxx .000 .040 .041 .061
Electr. Input
Display range
Resolution
Display
Contact
Operating voltage
Model
Protection
Dimensions
Weight
0 ... 834 Hz
0 ... 20 mA
4 ... 20 mA
0 ... + 10 V
0 ... 40.0 m/s, or
depending on sensor
type
± 1 Digit
LED, red, 13 mm high
throw-over-switch
230 V / 50 Hz
switch panel mounting
IP 20
96 x 48 x 104 mm
0.3 kg
Indicator
Analogue indicator for the
direct connection to the
Wind Transmitter (small
model),
order-no. 4.3400.30.000
4.3421.00.000
Display range
Division
Electr. input
Model
Protection
Class
Dimensions
Weight
0 ... 35 m/s
0 ... 65 kn
0 ... 12 Beaufort
2 m/s
5 kn
0 ... 1 mA DC
wall mounting case
IP 65
2
122 x 120 x 85 mm
0.55 kg
Indicators, WD
Digital Indicator WD
for panel mounting
Flat-section indicator for
display of wind direction
values.
The background of the
indicator is black to facilitate
reading of the red digits.
Preferably switch panel or
front panel installation.
4.1044.10.xxx .040 .041 .061
Display range
Electr. input
Resolution
Display
Operating voltage
Model
Protection
Dimensions
Weight
0 ... 360°
0 ... 20 mA
4 ... 20 mA
0 ... + 10 V
± 1 digit
LED, rot, 13 mm high
230 V / 50 Hz
switch panel mounting
IP 20
96 x 48 x 104 mm
0.3 kg
Combined Indicators WS/WD
Combined Indicator
Digital indicator which indicates
wind direction in a circle of
red LED's and wind speed in
digits in the centre of the circle.
Yellow scale inscription on
black background.
Suitable measuring
transmitters of the Small
Wind Transmitters-Line:
Small Wind Transmitter
4.3515.30.000
Wind direction transmitter
4.3127.40.000
0 ... 99.9 m/s, or
0 ... 99.9 kn
0 ... 360°
0.1 m/s resp. kn
22.5°
3-digits LED
7 segment red, 8 mm
high
16 LED bars, red
230 V / 50 Hz or
11 - 24 V DC
switch panel mounting
IP 42
96 x 96 x 110 mm
0.6 kg
Combined Indicator
Digital indicator which indicates
wind direction in a circle of
red LED’s and wind speed in
digits in the centre of the circle.
Yellow scale inscription on
black background.
Suitable measuring transmitters
of the compact-line :
Wind transmitter
4.3518.00.000
Wind direction transmitter
4.3128.00.000
0 ... 99.9 m/s, or
0 ... 99.9 kn
0 ... 360°
0.1 m/s resp. kn
22.5°
3-digits LED
7 segment red,
8 mm high
16 LED bars, red
220 V / 50 Hz or
12 - 24 V DC
switch panel mounting
IP 42
96 x 96 x 110 mm
0.6 kg
Wind Display LED
Digital indicator for the display of wind speed and wind direction.
Indicates the wind direction in
a circle of 72 LED luminous
bars, and the speed by 7-segment-
LEDs.
In addition, the minimum and
maximum wind speed values
can be indicated by two other
digit displays.
Display options of the WS:
• instantaneous value
or
• 2 min. mean value and
maximum value
or
• 10 min. mean value and
maximum value
Display options of
the WD:
• instantaneous value
or
• 2 min. mean value and
variation
or
• 10 min. mean value and
variation
The calculation of the mean
values and maximum values is
carried out according to the
ICAO.
The calculation of the mean
values and maximum values
is carried out according to the
ICAO.
A built-in RS-422-interface
facilitates the connection of
other wind indicators LED:
Suitable wind transmitters:
4.3303.22.000 / 008
4.3125.32.100
4.3336.31.000
4.3351.00(10).000
4.3150.00(10).000
4.3820.xx.xxx
4.3519.00.000
4.3129.00.000
4.3129.60.000
Connection
Ambient temp.
Model
Protection
Dimensions
Weight
EMC
230 V / 50 Hz;
24 V AC;
12 V –35 V DC
115 V / 50 Hz;
24 V AC;
12 –35 V DC
0...99.9 / 0…999
m/s / kt / km/h / Bft
0...360°
0.1 / 1
5°
0...1600 Hz
Thies- synchronous
serial
serial data telegram
via RS 422
RS 422
Screw terminal
-10...+50°C
switch panel mounting
IP 50
144 x144 x135 mm
1.5 kg
EN 60945
EN 61000-6-2
EN 61000-6-3
Wind Display LED
- Ship version -
Digital display instrument which
indicates the wind speed and
wind direction.
Indicates the wind direction in a
circle of 72 LED luminous bars,
and the speed by 7-segment-
LEDs.
Ship version with direction
circle
divided in red and green LED's
according to port side and starboard.
Display of WS:
• instantaneous value
Display options of the WD:
• instantaneous value or delayed
or
• instantaneous value and variation
or
• delayed and variation
When using a suitable sensor
electronics the display of
the “true” wind values is
possible.
A built-in RS-422-interface
facilitates the connection of
other wind indicators LED.
230 V / 50 Hz;
24 V AC
12 V-35 V DC
115 V / 50 Hz;
24 V AC
12 V-35 V DC
0-99.9 / 0-999
m/s / kn / km/h / Bft
0°-180°-0°
(0-360°)
0.1 / 1
5°
0-1600 Hz
Thies-serial-
synchronous
Serial data telegram
via RS 422
1 x RS 422
LED-standard
ultrasonic
NMEA 0, NMEA 1
Screw terminal
-10 ... +50 °C
Switch panel
mounting
IP 23
144 x 144 x 135 mm
1.5 kg
Wind Display LED
- Ship version -
For the display of “true”
and “relative” wind values.
True = real wind speed and wind direction
Relative = seeming wind speed
and wind direction
Data from the wind transmitter and data, according to NMEA 0183, coming from a compass system (ship heading “Gyro”) and the ship speed (LOG), are used to calculate the “true” wind-values via a built-in RS422 interface.
The selection for displaying the “true” or “relative” wind values is done through the mode-key on the front side.
4.3251.xx.001
Interface
Meas. value input
WS
WD
or
WD + WS
and
LOG + Gyro
Other techn.
data see above
4 x RS 422
0...1600 Hz
Thies- synchronous
serial
Serial data telegram
via RS 422
Serial data telegram
acc. to NMEA 0183
(DM)
Recorder
Continuous Line Recorder
Designed for the continuous
recording and the direct
reading of wind measuring
values.
Instrument as switchpanel-
installation housing.
Identification of individual
channels by different colour
pens.
9.3392.10.040 9.3393.10.040 9.3395.10.040
Number of channels
Electr. input
Accuracy
Print colour
Recording width
Paper advance
Model
Operating voltage
Ambient temp.
Type of protection
Dimensions
Weight
1
2
3
0 ... 20 mA / 0 ... 10 V
class 0.5
blue, red, green
100 mm
20, 60, 120,
240 mm/h
switch-panel-mounting
230 V / 50 Hz
0 ... +50°C
IP 54 or IP 20
144 x 144 x 295 mm
6.2 kg
Recorder Roll
Recording chart in roll format
for the above line recorder.
205434
Roll length
32 m
Felt Pen
Spare pens for identification
of the different channels for
above line recorder.
205433 205432 205431
Colour
blue ( 1. channel )
red ( 2. channel )
green ( 3. channel )
Software
Meteo-Online
The software Meteo-Online is a
WINDOWS Program, compatible
to WINDOWS 98 / NT / 2000 /
ME/XP.
It serves for the visualisation
and documentation of meteorological
measuring values.
The visualisation is carried out
alternatively in graphical form
as diagram and/or with text.
The user has the possibility
to place the display-elements
free on the screen.
The documentation can be
recorded in hour's- or day's
files with selectable averaging
periods for the respective
parameters. The documentation
files are ASCII-files, and
can be imported, for example,
directly into EXCEL. All THIESinstruments
with serial data
output can be connected via
the serial interface of a PC.
According to the number of
serial interfaces it is possible
to administrate several
instruments at the same time.
The Client Server Concept offers
the possibility of documenting
data in the background without
active visualisation
9.1700.98.000
Connectable
Wind Interface
Wind Display
Datalogger
US-Anemometer
Meteo comp
Illustration
Wind direction
Wind speed
Time intervals
Thies instruments
4.4070.01.706
4.3250.xx.000
9.1740.xx.x1x
4.3800.xx.xxx
4.3810.xx.xxx
4.3329.00.000 with
9.3229.00.000
numerals
diagram
wind rose
time
date
instantaneous value
variation
mean value, gliding
instantan, value 1 s
mean value, gliding
min. and max. value
Description and data same as above,
however with data monitor for checking
the incoming measuring values additionally
on threshold values or alarm parameters.
Wind Alarm Unit 2
Triggers a threshold value
contact for a set velocity value.
There are two LEDs on the front
plate which indicate the operational
control and the switching
status of the alarm threshold.
The delay times, the switching
point and the measuring intervals
can be set by means of the
rotary switch on the front
panel.
There is a code switch to set
the following wind transmitter
models:
4.3303.22.000
4.3515.30.000
4.3515.50.000
4.3518.00.000
4.3519.00.000
4.3520.00.000
Operating voltage
230 V / 50 Hz
230 V / 50 Hz
24 V AC/DC
24 V AC/DC
12 V AC/DC
Alarm range
Resolution
Electr. input
Switching point
Switch-on-delay.
Switch-off-delay.
Measuring interval
Relay output
Contact load
Ambient temp.
Operating voltage
Protection
Dimensions
Weight
incl. supply for heating
w/o supply for heating
incl. supply for heating
w/o supply for heating
w/o supply for heating
1 ... 39 m/s
0.1 m/s
see models
selectable in 1 m/s
1 - 9 s resp. 2 – 18 s
1 - 9 resp. 2 - 18 min.
depends on time
intervals
1 s or 2 s selectable
change-over switch,
one-pole
200 W / 24 V DC
100 W / 250 V DC
1000 VA, max. 8 A
-25 - + 55 °C
230 V / 50 Hz
IP 65
200 x 120 x 75 mm
1 kg
Wind Alarm Unit 3
For the display of the current
wind speed values and for
triggering a threshold value
contact.
Switches on the front plate
for setting the switching point
and the switch-on/switchoff-
delays.
Suitable wind transmitter
Best.-Nr. 4.3303.22.000
Measuring range
Electr. input
Display
Contact load
Switching point
Switch-on delay
Switch-off delay.
Operating voltage
Protection
Dimensions
Weight
0 ... 50 m/s
0 ... 1042 Hz
00.0 ... 99.9 m/s
200 W / 24 V DC
100 W / 250 V DC
2000 VA, max. 8 A
0 ... 50 m/s, selectable
0 - 18 s, in 9 steps
0 - 18 min., in 9 steps
230 V / 50 Hz
IP 65
200 x 120 x 75 mm
1 kg
Wind Alarm Unit 4
For digital display of the
current wind speed value.
Triggers two threshold value
contacts, for example early
warning and main alarm.
Switches on the front plate
for setting the switching
points and the switchon/
switch-off-delays.
Instrument with integrated
power supply unit for the
supply of the wind transmitter
heating.
Suitable wind transmitter
Best.-Nr. 4.3303.22.000
4.3242.02.000
Measuring range
Electr. input
Display
Contact load
Switching point
Switch-on delay.
Switch-off delay.
Operating voltage
Protection
Dimensions
Weight
0-50 m/s
0-1042 Hz
00.0-99.9 m/s
200 W / 24 V DC
100 W / 250 V DC
2000 VA, max. 8 A
2 x 0-50 m/s,
selectable
2 x 0-18 s,
in 9 steps
2 x 0-18 min.≤
in 9 steps
230 V / 50 Hz
IP 65
230 x 300 x 85 mm
2.6 kg
Wind alarm units in combination with wind transmitters
trigger preventive measures to protect wind-endangered objects.
Instrument Holder
For field installation of
meteorological measuring
instruments.
Consisting of mast tube,
mounting cross, earth pins for
ground installation or dowel
pins for fundament as well as
a staying and earth clamp.
4.3187.11.000
Length
Diameter of tube
Material
Weight
2.5 m
48 mm
steel, galvanised
ca. 12 kg
Instrument Holder
For the mounting of meteorological
measuring instruments in
buildings.
For wall mounting consists of
mast tube, 2 wall clamps and
an earth clamp.
4.3187.11.048 4.3187.11.060
Diameter of Tube
Length
Tube
Wall clamp
Earth clamp
Weight
48 mm
60 / 48 mm
4 m
Steel, galvanised
Aluminium
Aluminium
approx. 10 kg
Instrument Holder
For the mounting of meteorological
measuring instruments
in buildings.
For wall mounting consists
of mast tube, 1 wall clamp
(above), 1 tilting joint (below)
and an earth clamp.
4.3187.13.060
Diameter of tube
Length
Material
Tube
Wall clamp
Tilting joint
Earth clamp
Weight
60 / 48 mm
4 m
Steel, galvanised
Aluminium
Steel, galvanised
Aluminium
approx. 10 kg
Telescopic Mast for Field Installation
Telescopic Mast
For the field installation of
meteorological measuring
instruments. Mast with staying,
base plate and adaptor.
The base plate has a tilting
mast receptacle.
Aluminium,
sea-water-proof
Ø 49 mm
approx. 1.5 m
three-fold (4 m, 6 m)
six-fold (10 m)
max. 60 m/s
Grounding Set
To ground the preceding telescope
masts. Consists of a mast
ground clamp, a cross-bar, 2m
long, and a CU wire Ø 5 mm,
1 m long.
4.3186.00.000 4.3186.00.001 4.3186.00.002
Suitable for
4 m mast
6 m mast
10 m mast
Weight
Gripping diameter
60mm
80 mm
90 mm
4.5 kg
Telescopic Mast without Staying
Telescopic Mast
For the mounting of meteorological
measuring instruments.
This telescopic mast can be
used at a wall or in the open
country, in combination
with a respective tilting device,
without staying.
4.3179.30.080 4.3180.30.090 4.3181.30.116
4.3181.30.132
Length / Weight
4 m 15 kg
6 m 16 kg
10 m 43 kg
12 m 67 kg
Top of mast
Material
Diameter of tube
80 / 71 mm
90 / 80 / 71 mm
116 / 102 / 90 /
80 / 71 mm
132 / 116 / 102 /
90 / 80 / 71 mm
Ø 71 mm
Aluminium (AlMgSi1)
Tilting Devices
Tilting Device
For field mounting on fundament
The tilting device serves as
stand for a telescopic mast.
Telescopic mast and tilting
device are free-standing, and
do not need any staying.
For maintenance purpose the
telescopic mast can be tilted
by means of a rope winch
(optional accessory).
4.3181.03.080 .090 .116 .132
Suitable for
4.3179.30.080
4.3180.30.090
4.3181.30.116
4.3181.30.132
Height
Material
Weight
1580 mm
steel, galvanised
60 kg
Tilting Device
For wall mounting
The tilting device serves as
wall mounting device for a
telescopic mast.
For maintenance purpose the
telescopic mast can be tilted
by means of a rope winch
(optional accessory).
Suitable for
4.3179.30.080
4.3180.30.090
4.3181.30.116
4.3181.30.132
Material
Weight
steel, galvanised
32 kg
Mast Mounting Clamp
Type: LMB 80/90/116/132
For wall mounting of the
telescopic mast.
210363 210364 211278 210368
Suitable for
4.3179.30.080
4.3180.30.090
4.3181.30.116
4.3181.30.132
Diameter
Material
Weight
80 / 90 / 116 /
132 mm
Aluminium
0.5 / 0.7 / 1.3 /
1.5 kg
Mast Ground Clamp LE
Clamp to be mounted at the
mast foot for grounding the
mast by means of a wire with
diameter up to 9 mm.
210457 210458 211279 210460
Suitable for
4.3179.30.080
4.3180.30.090
4.3181.30.116
4.3181.30.132
Material
Weight
Gripping diameter
80 mm
90 mm
116 mm
132 mm
aluminium
ca. 0.13 kg
Traverses
Traverse
for Classic Wind Transmitters
For mounting the wind speed
transmitter and wind direction
transmitter jointly onto a mast.
The traverse is connected with
plug according to the transmitter
combinations.
Aluminium, anodised
(AlMgSi0,5)
Ø 34 x 4 mm
Ø 50 mm
0.6 m
0.2 m
0.76 m
3 kg
Traverse
for Classic Wind Transmitters
For mounting the wind speed
transmitter and wind direction
transmitter jointly onto a mast.
4.3172.00.000
Sensor distance
Vertic. Sensor distance
Total height
Mast clamp
Material
Weight
0.6 m
approx. 400 mm
650 mm
Ø 40-Ø 80 mm
Aluminium (AlMg3)
2.8 kg
Traverse
For Small Wind Transmitters
For mounting the wind
transmitter and wind direction
transmitter jointly onto a mast.
4.3171.20.000
Clamping range
Sensor distance
Material
Traverse
Gripping clamp
Weight
Ø 30 ... Ø 50 mm
0.5 m
Aluminium, anodised
(AlMgSi0,5)
stainless steel
0.35 kg
Traverse
for Wind Transmitters compact
For mounting the wind speed
transmitter and wind direction
transmitter jointly onto a mast.
4.3171.30.000 .31.
Clamping range
Sensor distance
Material
Traverse
Mounting set
Weight
Ø 48 ..... Ø 102 mm
Ø 116 ... Ø 200 mm
0.8 m
Aluminium
(AlMgSi0,5)
stainless steel (V2A)
0.30 kg
Traverse, short
for Wind Transmitters compact
For mounting the wind speed transmitter and wind direction transmitter jointly onto a mast.
4.3171.40.000 .41.
Clamping range
Sensor distance
Material
Traverse
Mounting set
Weight
Ø 48 ..... Ø 102 mm
Ø 116 ... Ø 200 mm
0.8 m from mast
Aluminium
(AlMgSi0,5)
stainless steel (V2A)
0.30 kg
Lightning Rod / Hangers / Holders / Adaptors
Lightning Rod
To be mounted additionally at
the telescopic mast, tube or
traverse. Protects the wind
transmitter against damages
caused by lightning strokes.
Suitable for:
Traverse: 4.3174.00.000
Mast or tube with Ø 48-50 mm
Mast or tube with Ø 48-50 mm
Mast or tube with Ø 71 mm
Traverse: 4.3173.01.001
Traverse: 4.3171.30/31/40/41…
Hanger, 1 m
The hanger is used for the
lateral mounting of a wind
transmitter, Classic type or
Ultrasonic-Anemometer, onto
a mast.
4.3185.xx.003 ...00.... ...01.... ...02....
Clamp range
For mast diameter
Tube diameter
Clamp range
Material
Weight
60-132 mm
40-80 mm
48-50 mm
1 m
34 mm
Aluminium
(AlMgSi0,5)
approx. 1.5 kg
Hanger-First Class-1 m
The hanger is used for the
lateral mounting of a wind
transmitter, First Class type,
onto a mast.
4.3184.01.000
Clamp range
For mast diameter
Length
Tube diameter
Material
Weight
40-80 mm
1 m
34 mm
Aluminium
(AlMgSi0,5)
approx. 1.5 kg
Holder compact
Serves for mounting the wind
transmitter compact onto a
mast tube.
506347
Material
Clamp range
Dimensions
Weight
stainless steel
Ø 35 – 50 mm
80 x 150 mm
0.35 kg
Adaptor
Serves for reducing the
diameter of the mast end tube
from 71 mm to 50 mm so that
Classic wind transmitters or USanemometers
can be mounted directly onto the mast top.
211545
Material
Weight
aluminium
1 kg
Adaptor
Serves for reducing the mast
diameter to 50 mm diameter
for mounting wind transmitters
of the classic types or ultrasonic
anemometers onto a mast top.
The POM (plastic)-model
insulates the measuring
instrument with the mast.
507936 508077 507555
Mast diameter
Diameter
Material
Weight
71 mm
60 mm
50 mm
145 mm high
Ø 110 / 95 / 70 mm
POM
0.9 / 0.7 / 0.4 kg
Adaptor 1"
Serves for reducing a traverse
tube diameter from 50 to 34 mm
in order to mount a wind transmitter
of the first class types.
507620
Material
Weight
Aluminium (AlMgSi1)
0.5 kg
Adaptor 1"
The adaptor is used to mount
wind measuring instruments
of the compact-series to a
1"- tube.
506283
Material
Weight
Aluminium (AlMgSi1)
0.5 kg
Mounting Set compact
Mounting holder with straps
for mounting of power supply
units, connection boxes
compact, and wind interfaces
onto masts or tubes.
506614 506971
Clamping range
Material
Weight
Ø 48-102 mm
Ø 116-200 mm
Stainless steel (V2A)
0.18 kg
Power Supply Unit
For the power supply of wind
speed transmitters, wind
directions transmitters or
combined instruments.
The outputs are each
protected by fuses.
The housing is made
of plastic fibre.
Suitable for:
Wind transmitter type:
• Compact
• Classic
• First Class
• Ultrasonic 2 D, 1D
230 V / 50Hz / 0.63 A
115 V / 60Hz / 1.3 A
2 x 24 V AC / 27.5 VA
1 x 24 V AC / 100 VA
1 x 24 V AC / 5 VA
1 x 24 V DC / 2 W
20-pole
plastic fibre
IP 65
300 x 230 x 132 mm
4.2 kg
Connection Box compact 1
For the power supply of wind
transmitters, wind direction
transmitters or combined
instruments.
With integrated over-voltageprotection
(varistors)
and terminal strip for the
connection and distribution
of the cables.
Suitable for:
wind transmitter type
• Compact
• Classic
• First Class
• Ultrasonic 1D
230 V / 50 Hz
115 V / 50 Hz
2 x 24 V AC / 27.5 VA
1 x 24 V AC / 75 VA
1 x 24 V DC / 5 W
1 x 24 V DC / 1.5 W
1 x 12 V DC / 2.5 W
For 16
measurement lines
All connections
Aluminium
IP 65
260 x 160 x 90 mm
(B x H x T)
4.5 kg
Connection Box compact
For the power supply of wind
transmitters, wind direction
transmitters or combined
instruments.
With integrated over-voltageprotection
(varistors)
and terminal strip for the
connection and distribution
of the cables.
Suitable for:
Wind transmitter type
• Compact
• Classic
• First Class
• Ultrasonic 3D, 2D, 1D,
2D compact
230 V / 50 Hz
1 x 24 V AC / 170 VA
1 x 24 V AC / 20 VA
1 x 24 V AC / 10 VA
1 x 24 V DC / 5 W
1 x 24 V DC / 1.5 W
1 x 12 V DC / 2.5 W
For 16 measurement
lines
All connections
Aluminium
IP 65
202 x 232 x 111 mm
(B x H x T)
4.5 kg