Humidity, Temperature, Pressure Wind Precipitation, Evaporation Radiation Logger; Power Supply; Connection Box Miscellaneous
WIND

Ultrasonic
Ultrasonic Anemometer compact
First Class advanced
Wind Glossary



Ultrasonic

       


Ultrasonic Anemometer 3D
The Ultrasonic Anemometer 3D serves for the 3-dimensional acquisition of the horizontal and vertical components of the wind velocity, the wind direction as well as of the acoustic-virtual temperature.

More than 70 different
measurement values are
available, for ex.:
• Wind velocity in X/Y/Z-direction
• Total wind velocity
• Wind velocity azimuth
• Wind direction azimuth
• Wind velocity elevation
• Wind direction elevation
• Acoustic-virtual temperature
• Standard deviation of the wind velocity in X/Y/Zdirection
• Standard deviation of the total wind velocity
• Standard deviation of the wind velocity azimuth
• Standard deviation of the wind direction azimuth
• Standard deviation of the wind direction elevation
• Standard deviation of the acoustic-virtual temperature
• Statistic functions such as variance, co-variance,
turbulence intensity
• Wind velocity X/Y/Z of the gust acc. to WMO
• Wind direction of the gust (elevation) acc. to WMO

The instrument is especially
suited for the use in the fields
of
• Meteorology
• Climatology
• Traffic engineering, aviation and navigation
• Indoor flow measurement
• And in alpine field of application

The ultrasonic measurement principle allows, compared to the classic anemometers, an inertia-free measurement of running variable dimensions with highest precision and accuracy. It is especially suited for the measurement of gustand peak values.

The measurement values can be output digitally and/or in analogue form.

The serial or analogue output of the data is carried out alternatively as instantaneous value or with selectable time frame.

If necessary, the sensor arms and the middle rod are automatically heated in case of critical ambient temperatures. Thanks to the additionally installed ultrasonic converter heating the instrument is suited even for the difficult application in locations where frequently icing is to be expected.

 

4.3830.2x.xxx 














































Wind velocity
Meas. range
Resolution


Accuracy



Direction
Meas. range
Azimuth
Elevation
Resolution
Accuracy

Virtual temp.
Meas. range
Resolution
Accuracy

Data output
digital
Interface
Baud rate
Output



Output rate


Status signal



Data output
analogue
Electr. output
(for wind vectors
XYZ or wv (azimuth),
wd (azimuth) and
acoustic-virtual temp.
Load
    Current output
    Voltage output

or as:
data input
output
dissolution

General
Bus operation
Operat. voltage
    Electronics
    with heating

Electr. connection
Housing material

Protection
Dimensions
Weight


0-65 m/s
0.1 m/s (standard)
0.01
(user-defined)
±0.1 m/s rms
(0-5 m/s)
±2% rms (< 5 m/s)



0-360°
-90°… +90°

±2°


-40 … +70 °C
0.1 K
±0.5 K
RS 485/422
1200 - 921600
instantan. values,
mean values,
standard deviations,
etc.
1 per 1 msec. up to
1 per 60 sec.

heating
distance error,
distance temperat.






0-20 mA/0-10 V
or
4-20 mA/2-10 V



max. 400 Ω
min. 4000 Ω


3 x 0-10 V
serial
16 bit


up to 98 instruments
8-24 V DC or
12-28 V AC/2.5 VA
24 V AC/DC,
typ 150 VA
8 pole plug
aluminium and
stainless steel (V4A)
IP 65
600 x 300 mm
1.5 kg

Anemometer Ultrasonic 2D
The Ultrasonic Anemometer 2D
serves for the 2-dimensional acquisition of the horizontal and vertical components of the wind velocity, the wind direction as well as of the acoustic-virtual temperature.

More than 35 different measurement values are available, for ex.:
• Orthogonal wind velocity vectors (X- and Y-distance)
• Scalar wind velocity
• Wind direction
• Acoustic-virtual temperature
• Acoustic-virtual temperature of the orthogonal measurement distances (X- and Y-distance)
• Standard deviation of the vectorial wind velocity (X and Y-distance)
• Standard deviation of the scalar wind velocity
• Standard deviation of the wind direction
• Standard deviation of the acoustic-virtual temperature
• Wind velocity of the gust acc. to WMO
• Wind direction of the gust acc. to WMO

The instrument is especially suited for the use in the fields of
• Meteorology
• Climatology
• Regenerative energy, wind energy plant
• Traffic engineering, aviation and navigation
• Pollutant dispersal
• Wind alarm devices, building construction and building safety
• Indoor flow measurement
• And in alpine field of application

The ultrasonic measurement principle allows, compared to the classic anemometers, an inertia-free measurement of running variable dimensions with highest precision and accuracy. It is especially suited for the measurement of gustand peak values.

The measurement values can be output digitally and/or in analogue form.

The serial or analogue output of the data is carried out alternatively as instantaneous value or with selectable time frame.

If necessary, the sensor arms are automatically heated in case of critical ambient temperatures. The possibility of malfunction, caused by icing, is minimized.

Model no. 4.3820.3x.xxx, thanks to the additionally installed ultrasonic converter heating, is suited even for the more difficult use in locations where frequently icing is to be expected.

4.3820.xx.xxx 
.0x.        
.3x.        
 







With heating
With heating

Velocity
Measuring range
Resolution


Accuracy



Direction
Measuring range
Azimuth
Resolution
Accuracy

Virtual temperature
Measuring range
Resolution
Accuracy

Data output digital
Interface
Baud rate
Output



Output rate

Status signal



Data output analogue
Electr. output
for wv, wr, acoustic-
virtual temperature
Load
    Current output
    Voltage output
or as:
data input
output resolution


General
Bus operation
Operat. voltage
    Electronics
    with heating

Electr. connection
Housing material

Protection
Dimensions
Weight






For sensor arms
For sensor arms and
ultrasonic-sensors

0-75 m/s
0.1 m/s (standard)
0.01
(user-defined)
±0.1 m/s rms
(0-5 m/s)
±2% rms (< 5 m/s)


0-360°
-90° …. +90°

±2°


-40 … +70 °C
0.1 K
±0.5 K


RS 485/422
1200-921600
instantan. values,
mean values,
standard deviations,
etc.
1 per 1 msec. up to
1 per 60 sec.
heating
distance error,
distance temperat.


0-20 mA/0-10 V or
4-20 mA/2-10 V


max. 400 Ω
min. 4000 Ω

3 x 0-10 V
serial
16 bit


up to 99 instruments
8-24 V DC or
12-28 V AC/2.5 VA
24 V AC/DC,
typ. 80 VA
8 pole plug
aluminium and
stainless steel (V4A)
IP 65
600 x 300 mm
2.5 kg

Accessories

       

Device to Refuse Birds
The device protects the ultrasonic converter of the ultrasonic anemometer (4.3820.xx.xxx).
The device shall prevent saller birds from sitting on the instrument.

507245             
     
Device to Refuse Birds
• consisting of:
    • Pin and
    • protective cap
A pin to be screwed onto the shaft, shall protect the instrument against bigger birds and prevent them from sitting on.


508396             
212352      
       
     
Connecting Cable
Suited for 4.3820/30........
Shielded cable, ready for connection with plug on sensor and cable end sleeve on the other end.
507751             
507752             
507753             
507754             
507755             
Cable length 15 m
20 m
25 m
30 m
40 m
 
Software Meteo-Online 9.1700.98.000 s. page 46    
Ultrasonic Anemometer compact
The Ultrasonic Anemometer compact serves for the 2-dimensional acquisition of the horizontal components of the wind velocity, the wind direction and the acoustic-
virtual temperature.

The following measuring values are available:
• Orthogonal wind velocity
vectors (X- and Y-distance)
• Scalar / vectorial wind velocity
wind direction
• Acoustic-virtual temperature
• NMEA data protocol
• ASCII THIES FORMAT
• Analogue data output *

The instrument is especially suited for the use in the fields of
• Regenerative power generation,
wind power plants
• Industrie automation
• Wind warning devices, building
construction and building
security
• Traffic engineering, aviation
and navigation
• Meteorology
• Climatology

The measurement principle allows, compared to the classic anemometers, an inertia-free measurement of running variable dimensions with highest precision and accuracy.

The measurement values can be output digitally and/or in analogue form.

The serial or analogue output of the data is carried out alternatively as instantaneous value or as gliding mean value with selectable time frame.

If necessary, the instrument is automatically heated in case of critical ambient temperatures. Thus, the possibility of malfunction, caused by icing, is minimized. The sensor arms and the ultrasonic sensors are heated.






* only in HD (half duplex)
operation
4.387x.0x.xxx
0.0x.xxx
1.0x.xxx

Mast boring
Mast boring

Velocity
Measuring range
Resolution


Accuracy



Direction
Measuring range
Azimuth
Resolutlion
Accuracy

Virtual Temp.
Measuring range
Resolution
Accuracy

Data output digital
Interface
Baud rate
Output

Output range

Status signal



Data output analogue
Electr. output
for WV, WD,
ac.- virtual temp.
Load
    Current output
    Voltage output
resolution

General
Bus operation
Operation voltage
    Electronic

    with Heating

Electr. connection
Housing
Protection
Dimension
Weight

1"
1.5"


0-60 m/s
0.1 m/s (standard)
< 0.1 m/s
(user-defined)
±0.2 m/s rms
(@ < 5 m/s)
±2% rms (> 5 m/s)


0-360°
1° (standard)
< 1° (user-defined)
±2° @v > 1m/s


-50 ... +70 °C
0.1 K
±2 K


RS 485 / 422
1200-921600
Instantan. values,
mean values
1 per 10 msec. up to
1 per 10 sec.
Heating, distance
error, distance
temperature


0-20 mA / 0-5 V /
0-10 V or 4-20 mA /
2-5 V / 2-10 V

max. 400 Ω
min. 2000 Ω
16 bit


Up to 99 instruments

8-36 V DC or
24 V AC/1.2 VA
24 V AC/DC,
typ. 100 VA
8 pol. Plug
Alu, anodised
IP 65
Ø 200 x 129 mm
approx. 2 kg


Wind Velocity Transmitter

       


Wind Transmitter
The wind transmitters is designed for the directionindependent measurement of the horizontal air-flow.

The wind transmitter is equipped with a contact-free opto-electronic scanner, which causes an extremely low starting speed. At the output the measuring value is available as digital signal.

The heating is electronically controlled. A plug-connection is situated in the shaft of the instrument. The instrument is mounted preferably onto a mast or traverse. All essential parts are made of anodised Aluminium.

 

4.3303.22.xxx 
.000 
.007 


Meas. range
Electr. output


Load
Delay distance
Accuracy

Operating voltage
Electronics
Heating

General
Ambient temp.
Electr. connection
   with x.xxxx.xx.000
   with x.xxxx.xx.007

Mounting
Fixing boring
Dimensions
Protection
Weight


0.3-50 m/s
3-1042 Hz (live zero)
3-1042 Hz
(no live zero)
max. 60 m/s
5 m
±0.3 m/s/±2% of m.v.


3.3 ... 47 V DC
24 V AC/DC; 20 W


-35 ... +80°C


5-pole plug connection
7-pole plug connection

onto mast tube 1 1/2”
Ø 50 x 50 mm
Ø 315 x 230 mm
IP 55
1 kg

Wind Transmitter
This wind transmitter is designed for high wind velocities.

The instrument is equipped with a reinforced cup star.






4.3303.22.0xx 
008 
018 







Meas. range
Electr. output


Accuracy

Operating voltage
   Electronics
   Heating
Electr. connection

0.5-75 m/s
0-754 Hz (live zero)
0-754 Hz
(no live zero)
±0.5 m/s / ±2% of m.v.


3.3 ... 47 V DC
24 V AC/DC; 20 W
5-pole plug
connection
Wind Transmitter
The wind transmitter is equipped with a contact-free opto-electronic scanner. A connected electronics converts the speed-dependent frequency into an analogue output signal.






4.3303.22.xxx 
.0xx 
.6xx 
.x40 
.x41 
.x60 
.x61 
.x73 





Meas. range

Electr. output




Accuracy

Operating voltage
   Electronics
   Heating
Electr. connection

0,3 ... 50 m/s
0,3 ... 60 m/s
0 ... 20 m
4 ... 20 mA
0 ... 1 V
0 ... 10 V
0 ... 5 V
± 0,4 m/s / ± 2,5%
v. Mw.

15...24 V DC
24 V AC/DC ; 20 W
5-pole plug connection



Wind Transmitter
This wind transmitter is equipped with a DC-generator which produces a d.c-voltage with the rotation of the cup star. It is able to operate a respective display instrument directly (without current supply).


4.3105.22.000 








Meas. range
Electr. output

Load
Accuracy
Heating
Electr. connection


0.5 ... 35 m/s
0 ... 4.67 mA DC,
linear Ra = 400 Ω
max. 60 m/s
± 0.5 m/s/ ± 2% v. Mw.
24 V AC/DC; 20 W
5-pole plug connection


Wind Direction Transmitter

       


Wind Direction Transmitter
Measuring value transmitter for measuring the direction of the horizontal air flow.

Potentiometer-wind-directiontransmitters are equipped with a sliding potentiometer which offers a theoretically unlimited resolution.

The heating is electronically controlled. A plug-connection is situated in the shaft of the instrument. The instrument is mounted preferably onto a mast or traverse. All main parts are made of anodised aluminium.


4.3120.22.xxx 
.012 
.018 














Potentiometer

0 - 2000 Ω
0 - 400 Ω

Measuring range
Resolution
Accuracy
Operating voltage
   Potentiometer
   Heating

Load
Starting value
Damping coefficient
Ambient temperature
Electr. connection

Mounting
Dimensions
Protection
Weight

Measuring Range
360° (±2°)
358° (±3°)
5-lead circuit
0-360°

±1.5°

12 V DC, max 1.5 W
24 V AC/DC,
max. 20 W
max. 60 m/s
0.5 m/s at 90°
0.2-0.3
-35 ... +80 °C
8-pole plug
connection
onto mast tube 1 1/2"
415 mm high
IP 55
1.8 kg





Wind Direction Transmitter
Measuring value transmitter for measuring the direction of the horizontal air flow.

The wind direction transmitter is equipped with a contact-free scanning system which causes an extremely low starting speed, and operates in wear-resistant manner. The digital measuring signals are transformed by an internal measuring transformer.

The output is available as analogue current- or voltage signal.
4.3125.32.xxx 
.x40 
.x41 
.x60 
.x61 
.x73 















Analogue Output





Measuring range
Resolution
Accuracy
Load
Starting value
Damping coefficient
Operating voltage
Heating
Ambient temperature
Electr. connection
Mounting

Dimensions
Weight

0 - 20 mA
4 - 20 mA
0 - 1 V
0 - 10 V
0 - 5 V

0 - 360°
2,5°
± 2,5°
max. 60 m/s
< 0.6 m/s at 90°
0.2 ... 0,3
14 - 18 V DC
24 V AC/DC, max.20W
- 35 ... + 80 °C
5-pole plug connection
onto a mast tube
1 1/2”
415 mm high
1,8 kg






Wind Direction Transmitter
Measuring value transmitter for measuring the direction of the horizontal air flow.

The position of the wind vane is detected opto-electronically by a code disc, which causes an extremely low starting speed, and operates in wearresistant manner.

The output is available as serial or as parallel digital signal.





4.3121.32.000 
4.3125.32.100 



















Digital Output

Measuring range
Resolution
Accuracy
Load
Starting value
Damping coefficient
Operating voltage
   Electronics
   Heating
Ambient temperature
Electr. connection
with xx.xxxx.000

with xx.xxxx.100

Mounting
Dimensions
Protection
Weight

8-bit parallel
8-bit serial-syn.
0-360°
2.5°
±1.5°
max. 60 m/s
< 0.6 m/s at 90°
0.2-0.3

5 / 3.5-18 V DC
24 V AC/DC, max. 20 W
-35 ... +80 °C

19-pole plug
connection
7-pole plug
connection
onto mast tube 1 1/2"
415 mm high
IP 55
1.8 kg







Combined Wind Transmitter

       


Combined Wind Transmitter
Measuring value transmitter for the measurement of the wind speed and wind direction of the horizontal air flow.

The cup star revolution is scanned opto-electronically in contact-free and wear-resistant manner. It has an extremely low starting speed.

The position of the wind vane is detected opto-electronically by a code disc. The digital measuring signals are transformed by an internal measuring transformer.

The output signals are available as current or voltage signals.

The heating is controlled electronically. A plug connection is situated in the shaft of the instrument. The instrument is mounted preferably onto a mast. All main parts are made of anodised aluminium.


4.3324.31.xxx
 
.0xx 
.6xx 
.x40 
.x41 
.x61 
.x73 


















Meas. range WV

Electr. output




Meas. range WD
Accuracy



Load
Delay distance
Responsiveness
Damping coefficient
Operating voltage


Heating
Ambient temp.
Electr. connection
Fixing boring
Mounting
Total height
Protection
Weight


0.3-50 m/s
0.3-60 m/s
0-20 mA
4-20 mA
0-10 V
0-5 V

0-360°
±0.5 m/s or
±2.0%
of meas. value
±1.5°
max. 60 m/s
5 m
< 0.6 m/s at 90°
0.2-0.3
15-24 V DC or
24 V AC/DC,
w. heating
max. 40 W
-35 ... +80°C
multi-pole plug
Ø 50 x 50 mm
onto mast tube 1 1/2"
620 mm
IP 55
3.4 kg















Combined Wind Transmitter
Measuring value transmitter for the measurement of the wind speed and wind direction of the horizontal air flow.

The cup star revolution is scanned opto-electronically in contact-free and wear-resistant manner. It has an extremely low starting speed.

The position of the wind vane is detected opto-electronically by a code disc.

The output signals are available as frequency for wind speed, and as 8-bit-Gray-code (parallel) for wind direction.

The ship-version is equipped with a strengthened cup star and a smaller wind vane.
4.3324.31.000 
.001 













Model

Meas. range

Electr. output


Resolution
Accuracy


Operating voltage

Load
Delay distance
Responsiveness
Damping coefficient
Heating
Ambient temp.
Electr. connection
Fixing boring
Mounting
Total height
Weight

Standard land version
Ship version
0.3 ... 50 m/s
0 ... 360°
3 ... 1042 Hz
8-bit-Gray-code
(parallel)
0.05 m ; 2.5°
±0,3 m/s or
±2 % of meas. value
±1,5°
15 V DC (5 … 18 V) or
24 AC/DC, w. heating
max. 60 m/s
5 m
< 0.6 m/s at 90°
0.2 ... 0.3
max. 40 W
-35 ... +80°C
multi-pole plug
Ø 50 x 50 mm
onto mast tube 1 1/2”
620 mm
3,4 kg


Combined Wind Transmitter
Measuring value transmitter for the measurement of the wind speed and wind direction of the horizontal air flow.

The cup star revolution is scanned opto-electronically in contact-free and wear-resistant manner. It has an extremely low starting speed.

The position of the wind vane is detected opto-electronically by a code disc.

The output signals are available as frequency for the wind speed and as serialsynchronous 8-bit for wind direction.

The ship-version is equipped with a strengthened cup star and a smaller wind vane.
4.3336.21.000 
4.3336.31.000 
.001 





















Model


Meas. range wv
Meas. range wd
Electr. output wv
Electr. output wd

Resolution
Accuracy


Load
Delay distance
Starting value
Damping coefficient
Operating voltage
Heating
Ambient temp.
Electr. connection
Fixing boring
Mounting
Total height
Protection
Weight

for Datalogger
Standard land version
Ship version
0.3-50 m/s
0-360°
3-1042 Hz
8-bit serial-
synchronous
0.05 m; 2.5°
±0.3 m/s oder
±2% of meas. value
±1.5°
max. 60 m/s
5 m
< 0.6 m/s at 90°
0.2-0.3
4-18 V DC
40 W, 24 V AC/DC
-35 ... +80 °C
multi-pole plug
Ø 50 x 50 mm
onto mast tube 1 1/2"
620 mm
IP 55
3.4 kg




Wind Speed Transmitter

       


Wind Transmitter
"First Class"

The wind transmitter is designed for the acquisition of the horizontal component of the wind speed in the field of meteorology and environmental measuring technology, evaluation of location, and measurement of capacity characteristics of wind power systems. In the plain country the wind transmitter meets all requirements of IEC 61400.121-CD for a
1. class instrument. Special characters are a defined and optimised, dynamic behaviour also at high turbulence intensity, minimal over-speeding, and a low starting value. The measuring value is available at the output as digital signal. It can be transmitted to display instruments, recording instruments, data loggers as well as to process control systems. For winter operation the instrument is equipped with an electronically regulated heating, which guarantees a smooth running of the ball bearings, and prevents the shaft and slot from icing-up


4.3350.00.000
 
.10.        






























With heating
W/o heating

Measuring range
Accuracy
   0.3 ... 50 m/s

   50 ... 75 m/s
Linearity

Inclined flow
...mean deviation
   from the cosinus
   line

   Turbulence effect



Electr. output
Load
Delay distance
Operating voltage
   Electronics
   Heating
Ambient temp.
Electr. connection
Mounting
Fixing boring
Dimensions
Protection
Weight
Material
   Housing
   Cup star





0.3...75 m/s

< 3% of meas. value
or < 0.3 m/s
< 6% of meas. value
r > 0.999 95 (4..20m/s)


1% (in the range ±20°)



<1% (in the range up
to 30%turbulence
intensity)

1000 Hz at 50 m/s
max. 85 m/s
< 3 m

3.3 … 42 V DC
24 V AC/DC; 25 W
-50 ..+ 80°C
8-pole plug connection
onto mast tube R 1”
Ø 35 x 25 mm
290 x 240 mm
IP 55
0.5 kg

alu, anodised
carbon-fibre-reinforced
plastic











Wind Transmitter
"First Class" Advanced

• Low Power Instrument
• Digital output

The wind transmitter is designed for the acquisition of the horizontal component of the wind velocity in the field of meteorology and environmental measuring technology, evaluation of location, and measurement of capacity characteristics of wind power systems. In the plain country the wind transmitter meets all requirements of IEC 61400-12-1 for an Instrument of the accuracy class 0.5.

Special characters are a defined and optimised, dynamic behaviour also at high turbulence intensity, minimal over-speeding, and a low starting value.

The measuring value is available at the output as digital signal. It can be transmitted to display instruments, recording instruments, data loggers as well as to process control systems.

For winter operation the instrument (4-3351.00.000) is equipped with an electronically regulated heating, which guarantees a smooth running of the ball bearings, and prevents the shaft and slot from icing-up.


4.3351.00.000
 
.10.        






























With heating
W/o heating

Measuring range
Accuracy
0.3 ... 50 m/s

Linearity

Inclined flow
- mean deviation
from the cosinus
line
- Turbulence effect



Electr. output
Delay distance
Survival speed


Operating voltage
Electronics

Heating
Ambient temp.
Electr. connection

Mounting
Fixing boring
Dimensions
Protection
Weight
Material
Housing
Cup star





0.3 ... 75 m/s

< 2% of meas. value
or < 0.2 m/s
r > 0.999 95
(4 ... 20 m/s)

< 0.1%
(in the range ±20°)

< 1% (in the range up
to 30% turbulence
intensity)

1080 Hz @ 50 m/s
< 3 m
80 m/s
(max. 30 minutes)

3.3 … 42 V DC
0.3 mA with 3.3 V
< 0,5 mA with 5 V
24 V AC/DC; 25 W
-50 ... +80 °C
8-pole plug
connection
onto mast tube R 1"
Ø 35 x 25 mm
290 x 240 mm
IP 55
0.5 kg

alu, anodised
carbon-fibrereinforced
plastic










Wind Transmitter
“First Class” Advanced

• Analog output and
• Digital output

The wind transmitter is designed for the acquisition of the horizontal component of the wind speed in the field of meteorology and environmental measuring technology, evaluation of location, and measurement of capacity characteristics of wind power systems. In the plain country the wind transmitter meets all requirements of IEC 61400-12-1 for an accuracy class 0.5 instrument.

Special characters are a defined and optimised, dynamic behaviour also at high turbulence intensity, minimal over-speeding, and a low starting value.

The measuring value is available at the output as analogue signal and as rectangular digital signal.

For winter operation the instrument (4.3351.00.xxx) is equipped with an electronically regulated heating, which guarantees a smooth running of the ball bearings, and prevents the shaft and slot from icing-up.
4.3351.00.xxx 
.10.xxx 

.x0.140 






.x0.141 






.x0.161 
With heating
W/o heating

Electr. output
Analogue

Digital
    Sink output
    Source output

Electr. output
Analogue

Digital
    Sink output
    Source output

Electr. Output
Analogue

Digital
    Sink output
    Source output

General
Measuring range
Accuracy
    0.3-50 m/s

Linearity
Survival speed

Distance constant
Operating voltage
    Electronics
    Heating
Ambient temperature
Electr. connection

Mounting
Fixing boring
Weight
Material
    Housing
    Cup star




0-20 mA
(0.3-75 m/s)
1000 Hz at 50 m/s
1 max 250 mA
1 max 100 mA


4-20 mA
(0.3-75 m/s)
1000 Hz at 50 m/s
1 max 250 mA
1 max 100 mA


0-10 VDC
(0.3-75 m/s)
1000 Hz @ 50 m/s
1 max 250 mA
1 max 100 mA


0.3-75 m/s

< 2% of meas. range
Or < 0.2 m/s
> 0.99995 (4-20 m/s)
85 m/s
(min. 30 minutes)
< 3 m

15-24 V DC
24 V AC/DC; 25 W
-50 … +80 °C
8-pole plug
connection
Onto mast tube R 1"
Ø 35 x 25 mm
0.5 kg

Alu, anodised
carbon-fibrereinforced
plastic

Wind Direction Transmitter

       


Wind Direction Transmitter
"First Class"

• Low Power Instrument
With digital output (Thies serial-synchronous)

The wind transmitter is designed for the acquisition of the horizontal component of the wind direction in the field of meteorology and environmental measuring technology, evaluation of location, and measurement of capacity characteristics of wind power systems.
Special characters are a
defined and optimised,
dynamic behaviour as well as:
• High measurement accuracy and resolution
• High damping with small distance constant
• Low starting value
• Low power consumption
• Simple mounting

The measuring value is available at the output as digital signal. The output signal can be transmitted to display instruments, recording instruments, data loggers as well as to process control systems.

For winter operation the instrument (4.3150.00.xxx) is equipped with an electronically regulated heating.


4.3150.00.00x
 
.10.00x 




.x0.000 


.x0.001 
















With heating
W/o heating

Measuring range
Accuracy

Electr. output
Resolution

Electr. output
Resolution

Operating voltage
  Electronics
  Current consumption
Heating
Ambient temp.
Starting value
Distance constant

Damping ratio
Electr. connection

Mounting
Fixing boring
Dimensions
Protection
Weight
Material





0-360°
1° (0.5°)

8 bit serial-synchron
2.5°

10 bit serial-synchron
0.35°


3.3-42 V DC
1.4 mA. standby
24 V AC/DC; 25 W
-50 ... +80 °C
< 0.5 m/s at 10°
< 1 m (acc. to
ASTM D 5366-96)
D > 0.25
8-pole plug
connection
Onto mast tube R 1"
Ø 35 x 25 mm
390 x 240 mm
IP 55
0.7 kg
Alu, anodised













Wind Direction Transmitter
"First Class"

• Digital output RS 485

The wind transmitter is designed for the acquisition of the horizontal component of the wind direction in the field of meteorology and environmental measuring technology, evaluation of location, and measurement of capacity characteristics of wind power systems. Special characters are a defined and optimised, dynamic behaviour as well as:
• High measurement accuracy and resolution
• High damping with small distance constant
• Low starting value
• Low power consumption
• Simple mounting
The measuring value is available
at the output as digital signal.
The output signal can be transmitted
to display instruments,
recording instruments, data
loggers as well as to process
control systems.

For winter operation the instrument (4.3150.00.xxx) is equipped with an electronically regulated heating.

4.3150.00.400 
.10.400 












With heating
W/o heating

Measuring range
Accuracy

Resolution
Electr. output
  Interface
  Baud rate
Output telegram

Operating voltage
  Electronic
  Current consumption
Heating
Ambient temperature
Starting value
Distance constant

Damping ratio
Electr. connection

Mounting
Fixing boring
Dimensions
Protection
Weight
Material




0-360°

0.01° @ 12 bit
serial data flow

RS 485
1200-57600 baud
xxx.xx for ex. 075.36°


3.3-42 V DC
approx. 6 mA
24 V AC/DC; 25 W
-50 ... +80 °C
< 0.5 m/s at 10°
< 1 m (acc. to
ASTM D 5366-96)
D 0.25
8-pole plug
connection
onto a mast tube R 1"
Ø 35 x 25 mm
390 x 240 mm
IP 55
0.7 kg
Alu, anodised













Wind Direction Transmitter
"First Class"

• Analogue output

The wind transmitter is designed for the acquisition of the horizontal component of the wind direction in the field of meteorology and environmental measuring technology, evaluation of location, and measurement of capacity characteristics of wind power systems. Special characters are a defined and optimised, dynamic behaviour as well as:
• High measurement accuracy and resolution
• High damping with small distance constant
• Low starting value
• Low power consumption
• Simple mounting
The measuring value is available at the output as analogue signal. The output signal can be transmitted to display instruments, recording instruments, data loggers as well as to process control systems. For winter operation the instrument (4.3150.00.xxx) is equipped with an electronically regulated heating.

4.3150.00.xxx 
.10.xxx 




.x0.140 



.x0.141 



.x0.161 









With heating
W/o heating

Measuring range
Accuracy
Resolution
Electr. output
Operating voltage
  Electronics
  Current consumption
Electr. output
Operating voltage
  Electronics
  Current consumption
Electr. output
Operating voltage
Electronics
Current consumption
Heating
Ambient temperature
Starting value
Distance constant

Damping degree
Electr. connection

Mounting
Fixing boring
Dimensions
Protection
Weight
Material




0-360°

0.35°
0-20 mA

15-24 V DC
approx. 4.5 mA + Iout
4-20 mA

15-24 V DC
approx. 4.5 mA + Iout
0-10 V

15-24 V DC
approx. 4.5 mA
24 V AC/DC; 25 W
-50 ... +80 °C
< 0.5 m/s at 10°
< 1 m (acc. to
ASTM D 5366-96)
D > 0.25
8-pole plug
connection
onto a mast tube R 1"
Ø 35 x 25 mm
390 x 240 mm
IP 55
0.7 kg
Alu, anodised













Wind Direction Transmitter
"First Class"

• Potentiometer output
   with protective circuit

The wind transmitter is designed for the acquisition of the horizontal component of the wind direction in the field of meteorology and environmental measuring technology, evaluation of location, and measurement of capacity characteristics of wind power systems. Special characters are a defined and optimised, dynamic behaviour as well as:
• High measurement accuracy and resolution
• High damping with small distance constant
• Low starting value
• Hysteresis-free and non-wearing magnetic coupling between vane- and potentiometer-axis
• Electronic protective circuit for current limiting and against erroneous connection
• Simple mounting

The measuring value is available at the output as analogue signal. The output signal can be transmitted to display instruments, recording instruments, data loggers as well as to process control systems.

The electronic protective circuit prevents the potentiometer from overloading in case of erroneous connection and on transition from 0° to 360°. The protective circuit represents a multiplier of 50 Ω, however limits the short cut current on transition from 0° to 360° (and vice-versa) to  1 mA at 10 k Ω Potentiometer and  2 mA with a 2 k Ω potentiometer.

For winter operation the instrument (4.3150.00.xxx) is equipped with an electronically regulated heating.

4.3150.00.x1x 
.10.x1x 




.x0.110 





.x0.012 









With heating
W/o heating

Measuring range
Accuracy

Electr. output
Multiplier
Operating voltage
Potent./electronics
Current consumption

Electr. output
Operating voltage
Potent./electronics
Current consumption

Heating
Ambient temp.
Starting value
Distance constant

Damping ratio
Electr. connection

Mounting
Fixing boring
Dimensions
Protection
Weight
Material




0-360°
< 1.5°

Potentiometer 10 KΩ
50 Ω

4-42 V DC
Us / 10 kΩ

Potentiometer 2 KΩ

4-42 V DC
Us / 2 kΩ

24 V AC/DC; 25 W
-50 ... +80 °C
< 0.5 m/s at 10°
< 1 m (acc. to
ASTM D 5366-96)
D > 0.25
8-pole plug
connection
onto a mast tube R 1"
Ø 35 x 25 mm
390 x 240 mm
IP 55
0.7 kg
Alu, anodised













Wind Direction Transmitter
"First Class"

• Potentiometer output

The wind transmitter is designed for the acquisition of the horizontal component of the wind direction in the field of meteorology and environmental measuring technology, evaluation of location, and measurement of capacity characteristics of wind power systems.
Special characters are a defined and optimised, dynamic behaviour as well as: • High measurement accuracy
and resolution
• High damping with small distance constant
• Low starting value
• Hysteresis-free and nonwearing magnetic coupling between vane- and potentiometer-axis
• Electronic protective circuit for current limiting and against erroneous connection
• Simple mounting

The measuring value is available at the output as analogue signal. The output signal can be transmitted to display instruments, recording instruments, data loggers as well as to process control systems.
For winter operation the instrument (4.3150.00.xxx) is equipped with an electronically regulated heating.

4.3150.00.212 
.10.212 



With heating
W/o heating

Measuring range
Accuracy

Electr. output
Operating voltage
Potent./electronics
Current consumption

Heating
Ambient temp.
Starting value
Distance constant

Damping ratio
Electr. connection

Mounting
Fixing boring
Dimensions
Protection
Weight
Material




0-360°
< 1.5°

Potentiometer 2 KΩ

0-30 V DC
Us / 2 kΩ

24 V AC/DC; 25 W
-50 ... +80 °C
< 0.5 m/s at 10°
< 1 m (acc. to
ASTM D 5366-96)
D > 0.25
8-pole plug
connection
onto a mast tube R 1"
Ø 35 x 25 mm
390 x 240 mm
IP 55
0.7 kg
Alu, anodised















Wind Velocity Transmitters

       


Wind Transmitter compact
Measuring transmitter for the measurement of the horizontal wind speed with digital output signal (open collector). The cup-star consists of plastic, the housing is made of anodised aluminium and plastic. The instrument has a threaded pin PG 21 with 2 nuts for mounting.









4.3518.00.000
 
4.3520.00.000 
4.3520.10.000 











With heating
With heating
W/o heating
Measuring range
Accuracy

Resolution
Electr. output
Operating voltage
Current supply
Heating

Ambient temp.
Connection

Dimensions
Protection
Weight


open collector sink
open collector source
open collector source
0.5-50 m/s
±3% of meas. value
or ±0.5 m/s
< 0.1 m/s
2-573 Hz
10-28 V DC
20 mA
max. 20 W;
24 V AC/DC
-40 ... +70 °C
5 m cable. LiYCY
5 x 0.25 mm2
Ø 135 x 165 mm
IP 55
0.4 kg






Wind Transmitter compact
• Low Power Instrument with frequency output

Measuring transmitter for the measurement of the horizontal wind velocity with frequency output (active signal). Suitable for data loggers. The cup-star consists of plastic, the housing is made of anodised aluminium and plastic. The instrument has a threaded pin PG 21 with 2 nuts for mounting.
4.3519.00.000 

Measuring range
Accuracy

Resolution
Electr. output
Operating voltage
Current consumpt.
Heating

Ambient temp.
Cable

Dimensions
Protection
Weight

0.5-50 m/s
±3% of meas. value
or ±0.5 m/s
< 0.1 m/s
2-630 Hz
3.3-42 V DC
< 1 mA
max. 20 W;
24 V AC/DC
-40 ... +70 °C
12 m cable. LiYCY
5 x 0.25 mm2
Ø 135 x 165 mm
IP 55
0.75 kg
Wind Transmitter compact
• Analogue output

Measuring transmitter for the measurement of the horizontal wind speed with analogue output signals. The cup-star consists of plastic, the housing is made of anodised aluminium and plastic. The instrument has a threaded pin PG 21 with 2 nuts for mounting.
4.3519.00.xxx 
.140 

.141 

.161 
.167 
.173 
















Electr. output

0-20 mA

4-20 mA

0-10 V
0-2 V
0-5 V
Measuring range
Accuracy

Resolution
Operating voltage
   for 0-10 V output.
Current consumption
Heating

Ambient temp.
Connection

Dimensions
Protection
Weight

Load
(at with operat. volt.)
max. 500 Ω ;
(> 13 V DC)
max. 500 Ω ;
(> 13 V DC)
min. 1 k Ω
min. 1 k Ω
min. 1 k Ω
0.5-50 m/s
±3% of meas. value
or ±0.5 m/s
< 0.1 m/s
9-30 V DC or 24 V AC
13-30 V DC or 24 V AC
50 mA
max. 20 W;
24 V AC/DC
-40 ... +70 °C
12 m cable, LiYCY
6 x 0.25 mm2
Ø 135 x 165 mm
IP 55
0.75 kg












Wind Transmitter compact
• Model with plug connection

Model like 4.3518.00.000 and 4.3519.00.000/1xx however with implemented plug instead of connected cable.
4.3518.00.700 
4.3519.00.700 
4.3519.00.741 
4.3519.00.761 

Connection
Dimensions
   Height (with plug)
   Cup star
   Housing
Weight

7-pole plug

225 mm
Ø 135 mm
Ø 50 mm
0.4 kg



Wind Direction Transmitters

       


Wind Direction Transmitter compact
• Digital Parallel Output

Measuring transmitter for the measurement of the horizontal wind direction with digital output signal (Gray-code). The wind vane consists of plastic, the housing is made of anodised aluminium and plastic. The instrument has a threaded pin PG 21 with 2 nuts for mounting.


4.3128.xx.000
 
.00...      

.10...      










With heating
Without heating

Measuring range
Accuracy
Resolution
Output
Electr. output

Operating voltage
Heating

Ambient temperat.
Connection

Dimensions
   Height
   Wind vane
   Housing
Protection
Weight






0-360°
±5°
90°; 45°; 22.5°
2; 3; 4-bit Gray-Code
Open collector
(source)
10-28 V DC
max. 20 W;
24 V AC/DC
-30 ... +70 °C
5 m cable LiYCY
6 x 0.25 mm2

220 mm
215 mm
Ø 50 mm
IP 55
0.6 kg






Wind Direction Transmitter compact
• Digital Serial Output

Measuring transmitter for the measurement of the horizontal wind direction with digital output signal (Gray-code).

The wind vane consists of plastic, the housing is made of anodised aluminium and plastic.
The instrument has a threaded pin PG 21 with 2 nuts for mounting.
4.3129.00.000 















Measuring range
Accuracy
Resolution
Electr. output

Operating voltage
Current consumption
standby
active
Heating

Ambient temp.
Connection

Dimensions
   Height
   Wind vane
   Housing
Protection
Weight

0-360°
±5°
11.25°
5-bit serial-
synchronous
5-30 V DC

< 15 μA (5V)
< 200 μA (5V)
max. 20 W;
24 V AC/DC
-50 ... +70 °C
12 m cable, LiYCY
6 x 0.25 mm2

220 mm
215 mm
Ø 50 mm
IP 55
1.1 kg

Wind Direction Transmitter compact
• Analogue Output

Measuring transmitter for the measurement of the horizontal wind direction with analogue output signals.

The wind vane consists of plastic, the housing is made of anodised aluminium and plastic.
The instrument has a threaded pin PG 21 with 2 nuts for mounting.
4.3129.00.xxx 
.140 

.141 

.161 
.167 
.173 














Electr. output

0-20 mA
4-20 mA
0-10 V
0-2 V
0-5 V

Measuring range
Resolution
Accuracy
Operating voltage

for 0-10 V-output

Heating

Ambient temp.
Connecton

Dimensions
   Height
   Wind vane
   Housing
Protection
Weight

Load operating
voltage
@ 500 Ω; (> 15 V DC)
@ 500 Ω; (> 15 V DC)
@ 1 k Ω; (> 15 V DC)
@ 1 k Ω
@ 1 k Ω

0-360°
11.25°
±5°
8-30 V DC or
24 V AC
15-30 V DC or
24 V AC
max. 20 W;
24 V AC/DC
-40 ... +70 °C
12 m cable, LiYCY
6 x 0.25 mm2

210 mm
215 mm
Ø 50 mm
IP 55
1.1 kg







Wind Direction Transmitter compact
• Model with plug connection

Model like 4.3129.00.000/ 1xx however with implemented plug instead of connected cable.
4.3129.00.700 
.740 
.741 
.761 

Connection
Dimensions
   Height (with plug)
   Wind vane
   Housing
Weight

7-pole plug

270 mm
215 mm
Ø 50 mm
0.4 kg
Wind Direction Transmitter compact
• Analogue Output

Measuring transmitter for the measurement of the horizontal wind direction with analogue output signals.

The wind vane consists of plastic, the housing is made of anodised aluminium and plastic.
The instrument has a threaded pin PG 21 with 2 nuts for mounting.
4.3129.60.xxx 

.140 
.141 
.161 
.167 
.173 


Electr. output

0-20 mA
4-20 mA
0-10 V
0-2 V
0-5 V

Measuring range
Resolution
Accuracy
Operating voltage
   for 0-10 V-output
Heating

Ambient temp.
Connecton

Dimensions
Height
Wind vane
Housing
Protection
Weight

Load operating
voltage
@ 500 Ω; (> 12 V DC)
@ 500 Ω; (> 12 V DC)
@ 1 k Ω; (> 12 V DC)
@ 1 k Ω
@ 1 k Ω

0-360°
0.4°
±2°
8-30 V DC or 24 V AC
15-30 V DC or 24 V AC
max. 20 W;
24 V AC/DC
-30 ... +70 °C
12 m cable, LiYCY
6 x 0.25 mm2

210 mm
215 mm
Ø 50 mm
IP 55
1.1 kg







Wind Direction Transmitter compact
• Model with plug connection

Model like 4.3129.00.000/1xx however with implemented plug instead of connected cable.
4.3129.60.xxx 
.740 
.741 
.761 
.767 
.773 

Connection
Dimensions
   Height (with plug)
   Wind vane
   Housing
Weight

7-pole plug

270 mm
215 mm
Ø 50 mm
0.4 kg

Wind Velocity Transmitters

       


Small Wind Transmitter
Measuring instrument for the direction-independent measurement of the horizontal air flow in the open. The sensor is a small construction with a DC-generator, which is moved by the revolution of the cup-star. The transmitter is made of synthetic material






4.3400.30.000
 











Measuring range
Accuracy

Electr. output

Load
Fixing boring
Mounting
Ambient temp.
Cable

Dimensions
Protection
Weight


0.5 ... 35 m/s
± 5% of meas.range
or ± 0.5 m/s
0 ... 1 mA DC
Ra = 800 Ω
max. 60 m/s
Ø 35 x 35 mm
onto a mast tube 1"
-25 ... +60°C, ice-free
20 m, LiYY
2 x 0.25 mm2
Ø 134 x 175 mm
IP 54
0.3 kg




Small Wind Transmitter
Measuring instrument for the direction-independent measurement of the horizontal air flow in the open. The sensor is a small construction with a Reed-contact, which is activated by the revolution of the cup-star. The transmitter is made of synthetic material








4.3515.30.000 
















Measuring range
Accuracy


Electr. output
Resolution
Load
Contact load
RV
Fixing boring
Mounting
Ambient temp.
Cable

Dimensions
Protection
Weight
0.5-40 m/s
±0.5 m/s or
±5% of meas. value
50 Hz at 40 m/s
0.8 m wind run
max. 60 m/s
Reed-contact
max. 24V DC
0.5W; 100 Ω
Ø 35 x 35 mm
onto a mast tube 1"
-25 ... +60 °C, ice-free
20 m;
LiYY 2 x 0.25 mm2
Ø 134 x 175 mm
IP 54
0.3 kg





Small Wind Transmitter
Measuring instrument for the direction-independent measurement of the horizontal air flow in the open. The sensor is a small construction with a Reed-contact, which is activated by the revolution of the cup-star. The housing is made of synthetic material.














4.3515.xx.xxx 
.50.xxx 
.51.xxx 
.0xx 
.1xx 
.x00 
.x61 











With heating
Without heating
Instrument colour

Electr. output

Measuring range
Accuracy

Resolution
Load
Contact load

Fixing boring
Mounting
Ambient temp.
Cable

Dimension
Protection
Weight
max. 24 V DC; 24 W

white
black
0-100 Hz
0-10 V
0.8-40 m/s
±0.5 m/s or ±5%
of meas. range
0.4 m wind run (.x00)
max. 60 m/s
10 VA, max. 42 VDC
max. 0.4 A
Ø 35 x 35 mm
on mounting angle
-25 ... +60 °C
3 m; LiYY 4 x 0.5 mm2
resp. 2 x 0.5 mm2
Ø 134 x 160 mm
IP 54
0.3 kg










Small Wind Transmitters are ideal measuring transmitters
with best price/performance-ratio for standard requirements.

Applications:
Control technique
Building control system

Wind Direction Transmitters

       


Wind Direction Transmitter
Measuring sensor for the measurement of the horizontal wind direction in the open. The instrument is a small construction with a potentiometer or Reed-contact, which are activated in correspondence to the position of the wind vane. The instrument is made of synthetic material.










4.3124.30.018
 

4.3127.40.000 













Electr. output
Resolution

Electr. output
Resolution
Accuracy
Measuring range
Potentiometer load

Contact load
Load
Ambient temp.
Cable


Mounting
Dimension
Protection
Weight

0-400 Ω (358°)
0.5°, 5-lead circuit

8 Reed contacts
22.5°
±4°
0-358°/0-360°
max. 100 mA,
24 V, 2.5 W
0.5 W, max. 60 V DC
max. 60 m/s
-25 ... +60 °C, ice-free
20 m, LiYCY
5 x 0.25 mm2
or 9 x 0.14 mm2
onto a mast tube 1"
210 mm high
IP 54
0.55 kg








Wind Direction Transmitter
Measuring transmitter for the measurement of the horizontal wind direction. The measuring values are output as ohmic resistance-signals. The wind direction is detected by a wind vane, and is then transmitted to a potentiometer.
The outer parts of the instrument are made of corrosionresistant materials (plastic). Labyrinth gaskets protect the parts inside the instrument against humidity.
4.3140.51.010 












Measuring range


Electr. output

Responsiveness
Potentiometer load
Ambient temperature
Electr. connection
Dimensions
Protection
Weight

10°-350°
(20° dead-zone
in the north)
Potentiometer
0-1 KΩ (±3%)
1 m/s
max. 1.5 W
-25 ... +60 °C, ice-free
3 m cable
210 mm high
IP 54
0.3 kg


Combined Transmitter
Measuring transmitter for the measurement of wind velocity, wind direction and air temperature. Compact wind transmitter contruction for simple instrument mounting.

Wind vane, cup star and housing consist partially of fibre-reinforced plastic, housing brackets and mast boring of stainless steel and alu.
4.3329.00.510 








Wind velocity
   Measuring range


   Output
   Resolution
   Contact load

Wind direction
   Measuring range
   Sensor
   Output

Temperature
   Sensor
Ambient. temperature

Connection

Dimensions
   Height
   Housing
Mast boring

Protection
Weight

1 ... 40 m/s
1 Reed contact /
2 magnets
Potential-free pulses
typ. 2.3 Hz / ms-1
max. 10 VA, 0.5 A,
42 VDC

2.5 ... 357.5°
Potentiometer
0 ... 1 KΩ, 5° dead
zone in the North

NTC, 10 KΩ
-25 ... +60 °C
(ice-free )
15 m cable, LiYCY
6 x 0.25 mm2

418 mm
Ø 50 mm
Ø 31 mm
26 mm depth
IP 54
1 kg

Wind Transmitters for Air Flow

       


Ultrasonic Anemometer 1D
The Ultrasonic Anemometer 1 D serves for the measurement of the horizontal air flow of a fixed flow direction and the acoustic-virtual temperature.


Different measuring values are available, among others:
• Flow vector
• Scalar flow velocity
• Acoustic-virtual temperature
• Standard deviation of the wind velocity
• Standard deviation of the scalar air flow
• Standard deviation of the acoustic-virtual temperature
• Flow velocity of the gust


The instrument is especially suited for the use
• In the traffic engineering
• Indoor flow measurement
• In tunnels
• In tubes


The measurement principle allows, compared to the classic anemometers, an inertia-free measurement of running variable dimensions with highest precision and accuracy. It is especially suited for the measurement of gust- and peak values.


The measuring values can be output digitally and/or in analogue form.


The serial or analogue output of the data is carried out alternatively as instantaneous value or as gliding mean value with selectable time frame.


If necessary, the sensor arms are automatically heated with critical ambient temperatures.


4.3860.00.340
 





























 

Flow velocity
Measuring range
Resolution
Accuracy

 

 


Flow direction
   Measuring range
Virtual temperature
   Measuring range
   Resolution
   Accuracy


Data output digital
   Interface
   Baud rate
   Output

 

 


   Output rate


   Status signal

 

 


Data output analogue
   Electr. output
   for flow,
   direction and
   virtual temperature
Resolution
Load
   Current output
   Voltage output


General
Bus operation
Operating voltage
   Electronics


   With heating


Electr. connection
Housing material
Protection
Dimensions
Weight



0-65 m/s
0.1 m/s
±0.1 m/s rms
(0-5 m/s)
±2% rms (> 5 m/s)


1° or 181°

-50 ... +70 °C
0.1 K
±0.5 K


RS 485 / 422
1200-921600
Instantaneous values,
Mean values,
Standard deviations
etc.
1 per 1 msec. up to
1 per 60 sec.
Heating,
Distance error
Distance temperature


0-20 mA / 0-10 V
or
4-20 mA / 2-10 V

16 bit

max. 400 Ω
min. 4000 Ω


up to 99 instruments

8-42 V DC oder
12-28 V AC/2,5 VA
24 V AC/DC,
typ. 40 VA
8-pole plug
Stainless steel (v 4 A)
IP 65
424 x 278 mm
2.5 kg





















Wind Transmitter
for tunnel application

For the measurement of directional air flows especially in tunnels. Instrument sends frequency signals, depending on speed and related to the flow direction.

Instrument is equipped with a mounting bar.

Suitable for connection to the Measuring Transducer TW, order-no. 4.3348.xx.xxx

4.3515.30.000 















Measuring range
Resolution

Delay distance
Electr. output

Propeller type

Dimension
Operating voltage
Current supply
Ambient temp.
Cable

Dimensions
Weight
0.3 ... 20 m/s
approx. 0,05 m
wind run
3.3 m
0 ... 410 Hz
resp. 418 Hz
4-blade,
polypropylene
Ø 180 mm
15 V DC (10 - 16 V DC)
approx.. 15 mA
-20 ... +70 °C, ice-free
3 m, LiYCY
4 x 0.25 mm2
Ø 200 x 350 mm
5 kg




Measuring transmitter for directional air flows.

Applications:
Air Channels Shafts
Climatic Ducts
Street and Railway Tunnels
Wind Transmitter
for duct application

A fan wheel to determine the directional air flow in ducts. Mounting on a mast tube.

The fan wheel revolutions are scanned opto-electronically by a reflective light barrier in a contact-free manner, thus causing a low starting speed.

See also :
Measuring Transducer WG, order-no.. 4.3339.xx.xxx
4.3124.30.018 

4.3127.40.000 













Operating voltage


Measuring range
Resolution
Electr. output
Fan wheel type
dimensions
Ambient temp.
Cable
Fixing boring
Dimensions
Weight



15 V DC /
approx. 0.3 mA
24 V DC
< 0.25 ... 20 m/s
0.083 m wind run
0 ... 240 Hz
8-blade aluminium
Ø 100 mm
-20 ... +80°C, ice-free
1 m long
Ø 37 x 20 mm
108 x 148 x 65 mm
0.9 kg






Measuring transmitter for directional air flows.

Applications:
Air Channels Shafts
Climatic Ducts
Street and Railway Tunnels

Hand Instruments, Mech. Anemometer, Wind Measuring Systems

     





Cup-Anemometer
A measuring instrument designed for hand use to take direct wind speed readings. Made of plastic.


4.3008.01.000 


Measuring range


Dimensions
Weight


0 ... 120 km/h
0 ... 12 Beaufort
0 ... 70 kn
ø 100 x 205 mm
0.32 kg
Instrument case
(not depicted)
Transport and storage case for the above-mentioned anemometer.
4.3008.01.000 



Material
Dimensions
Weight

wood
155 x 145 x 135 mm
1.15 kg
Digital Anemometer
The portable instrument serves for the display of wind velocities

The system consists of a wind transmitter with connected cable, a display instrument and a transport case.
Wind transmitter and display instrument are made of corrosion-free materials (alu, plastic).
The control key is installed in a way that the instrument can be easily operated. A 9 V battery for the power supply of the system is situated in a compartment on the back side of the instrument.




      4.3406.00.000 

 Wind transmitter

 

 

 

 

 

 

 

 


 Display
 Instrument

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 Transport
 Case



Measuring range
Accuracy

Cable length

Dimensions
Weight
Ambient temperat.
Protection

Accuracy
Resolution
Measuring value



Display


Dimensions
Battery status
Meas. range
exceeding
Ident. gliding
mean value
Gliding mean value
in configuration

General μC-technology,
Compensation of
starting value, battery
control power supply

Connection
Ambient temperat.
Dimensions

Weight
Protection

Material
Dimensions
Weight


0.5 ... 50 m/s
±3% of meas. value
or ±0.5 m/s
0.5 … 1.5 m
(helix cable)
Ø 135 x 270
250 g
-30 … +70 °C (ice-free)
IP 54

1 digit
0.1 m/s
Wind velocity
as instantan. value
or 10 s gliding mean
value:
LCD-display
3-digits, 7-segment,
11.5 mm high
M/s
LOBAT
199.9

”+“

”+“ flashes





9 V-, alkalimanganese
battery

5-pole-plug
0 ... 60 °C
145 x 80 x 35
(l x w x h)
190 g
IP 50

Plastic
420 x 330 x 130
2 kg


Telescope
- suitable for Digital
Anemometer 4.3406.00.000

Serves as extended handhold of the wind transmitter for carrying out measurements at places which are difficult to reach.
4.3405.50.007 












Length
Weight
0.45-1.45 m
0.5 Kg


Wind Run Meter
Mechanical measuring instrument for direction-independent measurement of the horizontal air flow and display of the wind run. The display count cumulatively the wind run. Instrument is mounted on the top of a mast. All main parts are made of anodised or varnished aluminium




4.3018.10.000 












Counting range
Resolution
Digit height
Inclination of counter
Operating range
Load
Delay distance
Ambient temp.
Mounting

Fixing boring
Dimensions
Weight
0 ... 999 999.9 km
100 m wind run
7 mm
50 °
0.5 - 60 m/s
max. 60 m/s
5 m
- 35 ... + 80 °C
onto a mast tube 1 1/2”
acc.to DIN 2441
ø 50 x 50 mm
318 x 260 mm
1.3 kg


Mechanical Wind Recorder
A mechanical instrument designed to measure and record wind run and direction. A reading rule to determine both instantaneous and mean wind speed values is included in the shipment. The paper transport is carried out by a band mechanism with spring wound drive.




4.3900.20.000 












Measuring range

Scale division
Recording width ws
                               wd
Period of registration
Paper advance
Operating range
Ambient temp.
Mounting

Dimensions
Weight

0 ... 10 km wind run
0 ... 360°
1 km ; 30°
50 mm = 10 km
36 mm = 360°
31 days
10 mm/h.
0,5 ... 60 m/s
- 35 ... + 60 °C
onto a mast tube,
ø 48 mm
155 x 200 x 725 mm
10.5 kg



Recording Roll
(not depicted)
Wax coated paper for abovementioned wind recorder.
205242             



Paper length
Width of roll


sufficient for 31 days
120 mm

Instrument case
(not depicted)
For a safe transport of the above instrument to varying measuring places.
4.3905.20.000 




Material
Dimensions
Weight


wood, unvarnished
710 x 320 x 290 mm
12.5 kg

Wind Direction Measuring Instrument
Simple portable instrument, consisting of a mechanical wind vane, and a telescopic tripod stand.
There is a built-in compass to align the instrument to "North". Supplied in a carrying case

4.3019.21.000 








Measuring range
Division
Alignment
Stand, telescopic
Dim. of case
Weight



0 ... 360°
10° and N-NW-W ...N
by compass
28 to 115 cm
395 x 285 x 120 mm
1 kg



METEO comp
Complete measuring instrument, ready for connection, consisting of the following components:


 

Measuring value





wind direction
wind speed
temperature
wind-chill
min.- and max.-values
of the past 24 h.
Comb. Wind Transmitter
Small combined measuring transmitter for acquisition of the wind speed and wind direction as well as of the ambient temperature.

4.3329.00.000 





Operating voltage
Ambient temp.
Cable
Mounting
Dimensions
Weight

from display unit
-30 ... + 60 °C
20 m long, with plug
on pin ø 30 mm
200 x 450 mm
1 kg
Display Instrument
Digital LED-indicator inclusive power supply unit, with plug for the display of the abovementioned measuring values. The changing-over to the single values is carried out via keypad. Plug-connection of wind sensor, power supply unit and serial data output. Housing is suited for wall mounting.





9.3229.00.000 














Display ws
   Resolution

Display wd
   Resolution
Display temp.

   Resolution
Electr. output
Operating voltage
Ambient temp.
Dimensions
   Display
   Power supply unit
Weight
m/s ; km/h ; Bft
0.1 m/s ; 1 km/h ;
1 Bft
0 ... 360°
22.5°
-30 ... + 60 °C
-22 ... + 140 °F
0.1 K ; 0.1 °F
RS 232/V.24, serial
9 V DC / max. 500 mA
-30 ... + 60 °C, ice-free

95 x 155 x 35 mm
65 x 100 x 55 mm
0.23 kg; 0.51 kg




Software Meteo-Online 9.1700.98.000  See page 44
 
 

Clima Sensor D

       









 
Wind

Precipitation
Brightness
Twilight
Temperature
Air humidity
Clima Sensor D, WTF 4.9110.00.061 
X
X
X
Clima Sensor D, W 4.9100.00.061 
X
X
Clima Sensor D, TF 4.9111.00.061 
X
X
Clima Sensor D 4.9101.00.061 
X
The Clima Sensor D serves for the measurement of environmental data. These are available as
• Serial RS 485/422 telegram and as
• analogue outputs for further processing

The CLIMA Sensor D has an internal DCF77 receiver, which takes the time signal of an atomic clock, and integrates it into the data telegram.

Ranges of application are:
• Building control systems
• Control technique
• Green house technique
• Processing of the acquired data to recording or display instruments

Depending on the model, the following data can be measured by the Clima Sensor D:

• Wind velocity
• Precipitation (yes/no)
• Brightness in Eastern, Southern and Western direction
• Twilight
• Temperature
• Rel. humidity

The respective holder serves for the mounting at masts or plane surfaces, depending on the range of application.

Instrument with internal condensation shield

      Wind



     Precipitation




     Brightness
     for South
     East, West

     Twilight




     Temperature



     Air humidity

 

 


     Output

       Serial

 

 

 

 

 

 


       analogue







     General

 

 

 

 

 

 

 

 

 

 


     Dimensions

Measuring range
Accuracy


Measuring range
Sensitivity
Switch-off-delay

Measuring range
Spectral range
Accuracy

Measuring range
Spectral range
Accuracy


Measuring range
Measuring element
Accuracy

Measuring range
Accuracy



Type
Output


Output parameter



Signal
0 … 10 V
0V/10V

Load resistance



Operating voltage
Current consumption



Ambient temperature
Connection


Mounting

Weight

4.9110.00.061
4.9100.00.061
4.9111.00.061
4.9101.00.061

1 ... 40 m/s
± 0.5 m/s or
5% of meas. range

Precipitation yes/no
fine drizzle
approx. 2 minutes

0 ... 100 k Lux
700 ... 1050 nm
±10% of meas. value

0 ... 250 k Lux
700 ... 1050 nm
±10% of meas. value

-20 … +60 °C
Pt100 1/3 DIN
±0.5 k at > 1 m/s


0 … 100% rel. humidity
±3% in the range
10 … 90% rel. humidity


RS 422 / 485
1200-19200 baud
8N1, full-duplex/
halve-duplex-operation
Environmental data,
housing, temperature,
date, time, sensor
status, checksum

Depending on parameter
With precipitation yes/no

10 kW
( 100 kW with
precipitation)

16-28 VDC or 24 V AC
150 mA w/o condensation
shield,
approx. 600 mA with
condensation shield
-40 °C … +60 °C
10 m calbe; LiYCY
16 x 0.14 mm2,
UV-resistant
retaining clamp,
stainless steel
Max. 1.5 kg

Ø 130 x 430 mm
Ø 130 x 430 mm
Ø 130 x 430 mm
Ø 130 x 430 mm

Measuring Transformers

       


Measuring Transformer WV
Instantaneous value

The speed-dependent frequency generated by the wind transmitters is converted into a current or voltage signal. This allows the control of connected recording, display or switching devices.



Suitable for wind transmitters
4.331.3x.000
4.3303.22.000 / 007
4:3303.22.008 / 018















4.3339.xx.xxx
 
4.3340.xx.xxx 
.00...      
.10...      
.040 

.041 

.060 
.061 
.080 
.081 
.100 
.101 













Electr. output
0 ... 240 Hz, 15V
3... 1042 Hz, 15V
Model

Electr. output










Measuring value
Operating voltage
Ambient temp.
Protection

Dimensions
Wall mount. case
PC-board
Weight
Wall mount. case
PC-board




Measuring range
0 ... 20 m/s
0 ... 40/50/75 m/s
wall mounting case
pc-board
0 - 20 mA
(max. 600 Ω)
4 - 20 mA
(max. 600 Ω)
0 - 1 V (max. 10 mA)
0 - 10 V (max. 10 mA)
0 - 20 mA / 0 - 1 V
0 - 20 mA / 0 - 10 V
4 - 20 mA / 0 - 1 V
4 - 20 mA / 0 - 10 V

instantaneous value
230 V / 50 Hz
0 ... +40°C
IP 65
(wall mounting case)

200 x 120 x 75 mm
170 x 100 x 30 mm

0.65 kg
0.25 kg












Measuring Transformer WSM
Mean value

The speed-dependent frequency generated by the wind transmitters is totalled up over the selected integration time and, as a mean value, converted into a current or voltage signal. This allows the control of connected recording, display or switching devices.



Suitable for the wind transmitters of the classic-line with frequency output
4.3303.22.000 / 007
4.3303.22.008 / 018












4.3341.xx.xxx 
.00...      
.10...      
.040 

.041 

.060 
.061 
.080 
.081 
.100 
.101 

















Model

Electr. output










Electr. input
Measuring value
Measuring range

Time of integration


Operating voltage
Ambient temp.
Protection

Dimensions
Wall mount. case
PC-board
Weight
Wall mount. case
PC-board
Wall mounting case
PC-board
0 - 20 mA
(max. 600 Ω)
4 - 20 mA
(max. 600 Ω)
0 - 1 V (max. 10 mA)
0 - 10 V (max. 10 mA)
0 - 20 mA / 0 - 1 V
0 - 20 mA / 0 - 10 V
4 - 20 mA / 0 - 1 V
4 - 20 mA / 0 - 10 V

0 ... 1042 Hz (50 m/s)
mean value
selectable in 5 m/ssteps
up to 50 m/s
2.5/ 5 / 10 / 15 /
30 / 60 / 120 min,
selectable
230 V / 50 Hz
0 ... +40°C
IP 65
(wall mounting case)

200 x 120 x 75 mm
170 x 100 x 30 mm

0.7 kg
0.3 kg












Digital-Analog-Transducer TW
Mean value

The pulses from wind sensor 4.3308.10.000 are converted by the measuring transducer into standardized analogue output signals.
These output signals are available
1. as direction-dependent or
2. as direction-independent value.

Moreover, the following settings can be effected through the coding switch:

  Measuring range adaptation
  Delays for analogue signals
  Relay-output delay for dampening
of switching processes in case of short-time flow-turbulence.








4.3348.xx.xxx 
.00...      
.10...      
.040 

.041 

.060 
.061 




















Model

Electr. output






Measuring value
Measuring range
codable

Time of integration
codable
Relays-delay
Relay-load

Electr. input
Operating voltage
Ambient temp.
Protection

Dimensions
Wall mounting case
PC-board
Weight
Wall mounting case
PC-board
wall mounting case
PC-board
0 - 20 mA
(max. 600 Ω )
4 - 20 mA
(max. 600 Ω )
0 - 1 V (max. 10 mA)
0 - 10 V (max. 10 mA)

mean value
6 values up to 50 m/s,
5; 10; 20; 30; 40;
50 m/s

24; 48; 120; 240 s
codable, 1.5 ... 45 s
max. 200 W / 220 V /
8 A
2 x 15 V pulse
230 V / 50 Hz
0 ... +40°C
IP 65
(wall mounting case)

200 x 120 x 75 mm
170 x 100 x 30 mm

0.65 kg
0.25 kg











Wind Interface
Suitable Wind transmitters:
4.3519.x0.x00 / 4.3129.0x.x00

The wind interface transforms the digital signals of the wind speed- and wind direction transmitters into serial data telegrams. The interface allows the connection to different instruments, thanks to the interface variants available and the possibilities of forming the data telegram.

The voltage supply of the wind transmitter is effected via the wind interface. The housing is made of aluminium, and is suited for outside mounting.

4.4070.01.00x 
4.4070.01.70x 
x     

















Electr. output

Telegram variant

Input WS
          WD


Measuring value


Operating voltage
Protection
Dimensions
Weight





Fibre-optic-interface
RS 422
On request

0...713 Hz (50 m/s)
5-bit serial
synchronous

1 s instantaneous
value for WS and WD

24 V AC/DC ± 15 %
IP 65
84 x 179 x 67 mm
0.85 kg





















For wind transmitters:
4.3518.0x.x00 / 4.3128.xx.xx0

For wind transmitters:
4.3303.22.000 /
4.3125.32.100
4.4071.01.xxx 


4.4072.01.xxx 


Input WS
          WD

Input WS
          WR

0...648 Hz (50 m/s)
4-bit serial parallel

0...1042 Hz (50 m/s)
8-bit serial
synchronous
Mounting Set compact
Mounting clamp with straps to mount the wind interface onto masts
506614            


Clamping range
Material
Weight
Ø 48 ... 102 mm
stainless steel
0.18 kg

Combined Clima Sensors

     


Clima Sensor
WTF


Clima Sensor
W


Clima Sensor
TF


Clima Sensor

The Clima Sensor 2000 serves
for the measurement of
important environmental data.
Depending on the type of task
it is available as combined
measuring instrument.
The analogue outputs are
configured as standard signals
so that they can be used for
the coupling on customary bus
systems.

Wind
A cup star, the revolution-no.
of which is linear-proportional
to the wind speed, supplies
a frequency through a Reedcontact
to a connected
frequency-voltage-converter.

Precipitation
The detection is carried out
optically acc. to the reflectionmethod
with modulated
infrared-light on precipitation
particles.

Brightness
The brightness is detected by
means of three independent
photo-diodes which are arranged
in 90°-segments. Three
independent output voltages
are linear to the brightness.

Twilight
The twilight is detected by
a photo diode. A converter
transforms the signal into an
output voltage, which is linear
to the twilight range.

Temperature
The temperature sensor is
a standardized resistance
thermometer - Pt 100 - of
longterm stability.

Air humidity
The measurement is carried
out with a capacitive humidity
sensor changing its capacity
according to the relative
humidity.


4.9010.00.061


4.9000.00.061


4.9011.00.061


4.9001.00.061

Wind Speed




Precipitation-
Detection








Brightness
Detection







Twilight




Temperature






Humidity






General
Wind
Precipitation,
Brightness, Twilight
Temperature Air humidity
X


X
X


X


X


X
X





X




Meas. range
Accuracy
Electr. output
Load resistor
1 … 40 m/s
≤0.5 m/s
0 … 10 V (=0 ... 40 m/s)
≥10 kΩ

Meas. range
Electr... output

Sensitivity
Load resistor

Sensitivity
Switch off-delay
Precipitation yes/no
0 V at precipitation
10 V no precipitation
Drizzle
≥100 kΩ

Drizzle
approx. 2 min.


Meas. range
Spectral range
Accuracy
Electrical output


Load resistor
0 … 100 k Lux
700 … 1050 nm
±10% of meas. value
3 x 0 … 10 V,
Eastern, Southern
and Western Direction
≥10 kΩ


Meas. range
Electr. output
Load resistor
0 … 250 Lux
0 … 10 V
≥10 kΩ


Meas. range
Meas. element
Accuracy
Electr. output
Load resistor
-20 … +60 °C
Pt100 at IEC 751 1/3 DIN
±0.15 °C at 0 °C
0 … 10 V
≥10 kΩ


Meas. range
Accuracy

Electrical output
Load resistor
0 … 100% rel. humidity
±3% in the range
10 … 90% rel. h.
0 … 10 V
≥ 10 kΩ


Operating voltage

Current load
Temperature range
Connecting cable




Mounting

Weight
24 V AC ±15%
24 V DC ±25%
≤ 150 mA
-40 °C … +60 °C
10 m; LiYCY
12 x 0.14 mm2,
UV-resistant max.
100-m supply at with
nominal 24 V
Niro-holder clamp
on mast or wall
max. 1.5 kg

Combined Clima Sensors D

     
Clima Sensor D
WTF

Clima Sensor D
W

Clima Sensor D
TF

Clima Sensor D

The Clima Sensor D serves
for the measurement of
important environmental
data. Depending on the task,
it is available as combined
measuring instrument. Model
D is equipped in addition
with a DCF 7 radio controlled
clock, and an integrated serial
interface. An internal heating
serves as protection against
dew.

The instrument has
• Analogue outputs and
• Serial interface
• DCF77-receiver for
date and time
• Dew protection

The analogue outputs are standard
signals and can be used
for the connection to commercially
available bus systems.

Further description see
Clima Sensor
4.9110.00.061


4.9110.00.061


4.9111.00.061


4.9101.00.061



Wind


Precipitation




Brightness
for East, South,
West

Twilight

Temperature




Air humidity




Output
analogue





serial


General
Wind
Precipitation,
Brightness, Twilight
Temperature Air humidity
X


X
X


X


X


X
X





X




Measuring range
Accuracy

Measuring range
Sensitivity
Switch-off-delay.
Load resistance

Measuring range
Spectral range
Accuracy


Measuring range

Measuring range
Accuracy



Measuring range
Accuracy



Signal






Type
Output

Measuring values

Output rate

Operating voltage

Current
consumption

Ambient temp.
Connecting calbe



Mounting

Weight
0,5 ... 40 m/s
±0,5 m/s or ±5% Mb

rain yes / no
drizzle
approx. 2 minutes
≥ 100 kW

0 ... 100 k Lux
700 ... 1050 nm
±10% of measuring
value

0 ... 250 Lux

-20 ... +60 °C
1/3 class B acc.
to IEC 751
±0.1 °C at 0 °C

0 ... 100% rel. humidity
±3 in the range
10 ... 90% rel. h.


0 ... 10 V each
parameter 0 V for rain,
10 V with dryness
Load resistance
≥ 10 kW (≥ 100 kW
with precipitation)

RS 422/485
9600Bd, 8N1, simplex-,
half-duplex-operation
Instant. values,
date and time
1 / sec.

24 V AC ±15%
24 V DC ±25%
≤ 150 mA
(with heating < 650 mA)

-40 °C ... +60 °C
10 m; LiYCY 16 x
0.14 mm2, uv-resistant
max. 100 m at supply
with nominal 24 V
non-corrosive holding
clamp for mast or wall
max. 1.5 kg

Indicators, WS

       


Digital Indicator WG
for panel mounting

Flat-section indicator for the display of wind speed values. The background of the indicator is black to facilitate reading of the red digits. Preferably switch panel or front panel mounting






4.1044.00.xxx 
.000 
.040 
.041 
.061 










Electr. Input



Display range


Resolution
Display
Operating voltage
Model
Protection
Dimensions
Weight

0 ... 834 Hz
0 ... 20 mA
4 ... 20 mA
0 ... + 10 V
0 ... 40.0 m/s , or
depending on sensor
type
± 1 digit
LED, red, 13 mm high
230 V / 50 Hz
switch panel mounting
IP 20
96 x 48 x 104 mm
0.3 kg.




Digital Indicator WG
for panel mounting
with 2 adjustable limit contacts

Flat-section indicator for the display of wind speed values. Two setting knobs on the front panel serve for setting the two potential-free relay-contacts. LED-digits show the switching functions. The background of the indicator is black to facilitate reading of the red digits. Preferably switch panel or front panel mounting.


4.1045.00.xxx 
.000 
.040 
.041 
.061 










Electr. Input



Display range


Resolution
Display
Contact
Operating voltage
Model
Protection
Dimensions
Weight
0 ... 834 Hz
0 ... 20 mA
4 ... 20 mA
0 ... + 10 V
0 ... 40.0 m/s, or
depending on sensor
type
± 1 Digit
LED, red, 13 mm high
throw-over-switch
230 V / 50 Hz
switch panel mounting
IP 20
96 x 48 x 104 mm
0.3 kg




Indicator
Analogue indicator for the direct connection to the Wind Transmitter (small model),
order-no. 4.3400.30.000






4.3421.00.000 










Display range


Division

Electr. input
Model
Protection
Class
Dimensions
Weight
0 ... 35 m/s
0 ... 65 kn
0 ... 12 Beaufort
2 m/s
5 kn
0 ... 1 mA DC
wall mounting case
IP 65
2
122 x 120 x 85 mm
0.55 kg

Indicators, WD

       


Digital Indicator WD
for panel mounting

Flat-section indicator for display of wind direction values. The background of the indicator is black to facilitate reading of the red digits. Preferably switch panel or front panel installation.



4.1044.10.xxx
 
.040 
.041 
.061 






Display range
Electr. input


Resolution
Display
Operating voltage
Model
Protection
Dimensions
Weight

0 ... 360°
0 ... 20 mA
4 ... 20 mA
0 ... + 10 V
± 1 digit
LED, rot, 13 mm high
230 V / 50 Hz
switch panel mounting
IP 20
96 x 48 x 104 mm
0.3 kg

Combined Indicators WS/WD

       


Combined Indicator
Digital indicator which indicates wind direction in a circle of red LED's and wind speed in digits in the centre of the circle. Yellow scale inscription on black background.

Suitable measuring transmitters of the Small Wind Transmitters-Line:
Small Wind Transmitter
4.3515.30.000
Wind direction transmitter
4.3127.40.000



4.3228.30.000
 











Display range


Resolution

Display



Operating voltage

Model
Protection
Dimension
Weight

0 ... 99.9 m/s, or
0 ... 99.9 kn
0 ... 360°
0.1 m/s resp. kn
22.5°
3-digits LED
7 segment red, 8 mm
high
16 LED bars, red
230 V / 50 Hz or
11 - 24 V DC
switch panel mounting
IP 42
96 x 96 x 110 mm
0.6 kg








Combined Indicator
Digital indicator which indicates wind direction in a circle of red LED’s and wind speed in digits in the centre of the circle. Yellow scale inscription on black background.

Suitable measuring transmitters of the compact-line :
Wind transmitter
4.3518.00.000
Wind direction transmitter
4.3128.00.000


4.3228.40.000 














Display range


Resolution

Display



Operating voltage

Model
Protection
Dimension
Weight
0 ... 99.9 m/s, or
0 ... 99.9 kn
0 ... 360°
0.1 m/s resp. kn
22.5°
3-digits LED
7 segment red,
8 mm high
16 LED bars, red
220 V / 50 Hz or
12 - 24 V DC
switch panel mounting
IP 42
96 x 96 x 110 mm
0.6 kg




Wind Display LED
Digital indicator for the display of wind speed and wind direction.

Indicates the wind direction in a circle of 72 LED luminous bars, and the speed by 7-segment- LEDs.

In addition, the minimum and maximum wind speed values can be indicated by two other digit displays.

Display options of the WS:
• instantaneous value
or
• 2 min. mean value and
maximum value
or
• 10 min. mean value and
maximum value

Display options of
the WD:
• instantaneous value
or
• 2 min. mean value and
variation
or
• 10 min. mean value and
variation

The calculation of the mean values and maximum values is carried out according to the ICAO.

The calculation of the mean values and maximum values is carried out according to the ICAO.
A built-in RS-422-interface facilitates the connection of other wind indicators LED:
Suitable wind transmitters:
4.3303.22.000 / 008
4.3125.32.100
4.3336.31.000
4.3351.00(10).000
4.3150.00(10).000
4.3820.xx.xxx
4.3519.00.000
4.3129.00.000
4.3129.60.000
4.3250.xx.000 
.00...      


.01...      











































Operating voltage






Display range
   Wind speed

   Direction

Resolution
   Wind speed
   Wind direction

Wind transmitter input
   WS
   WD


or
   WD + WS


Interface

Connection
Ambient temp.
Model
Protection
Dimensions
Weight
EMC














230 V / 50 Hz;
24 V AC;
12 V –35 V DC
115 V / 50 Hz;
24 V AC;
12 –35 V DC


0...99.9 / 0…999
m/s / kt / km/h / Bft
0...360°


0.1 / 1




0...1600 Hz
Thies- synchronous
serial

serial data telegram
via RS 422

RS 422

Screw terminal
-10...+50°C
switch panel mounting
IP 50
144 x144 x135 mm
1.5 kg
EN 60945
EN 61000-6-2
EN 61000-6-3

















































Wind Display LED
- Ship version -

Digital display instrument which indicates the wind speed and wind direction. Indicates the wind direction in a circle of 72 LED luminous bars, and the speed by 7-segment- LEDs.

Ship version with direction circle divided in red and green LED's according to port side and starboard.

Display of WS:
• instantaneous value


Display options of the WD:
• instantaneous value or delayed
or
• instantaneous value and variation
or
• delayed and variation


When using a suitable sensor electronics the display of the “true” wind values is possible.


A built-in RS-422-interface facilitates the connection of other wind indicators LED.


Suitable wind transmitters:
4.3303.22.000 / 008
4.3125.32.100
4.3336.31.001
4.3351.00(10).000
4.3150.00.000
4.3820.xx.xxx

4.3251.xx.000 
.00...      


.01...      
































 

Operating voltage





Display range
   Wind velocity

   Direction

Resolution
   Wind speed
   Wind direction

Wind transmitter input
   WS
   WD

or
   WD + WS


Interface
Data telegram



Connection
Ambient temp.
Model


Protection
Dimensions
Weight


 

230 V / 50 Hz;
24 V AC
12 V-35 V DC
115 V / 50 Hz;
24 V AC
12 V-35 V DC

 


0-99.9 / 0-999
m/s / kn / km/h / Bft
0°-180°-0°
(0-360°)


0.1 / 1

 


0-1600 Hz
Thies-serial-

synchronous


Serial data telegram
via RS 422


1 x RS 422
LED-standard
ultrasonic
NMEA 0, NMEA 1


Screw terminal
-10 ... +50 °C
Switch panel
mounting
IP 23
144 x 144 x 135 mm
1.5 kg


Wind Display LED
- Ship version -

For the display of “true”
and “relative” wind values.

True =       real wind speed and wind                    direction
Relative = seeming wind speed
                   and wind direction

Data from the wind transmitter and data, according to NMEA 0183, coming from a compass system (ship heading “Gyro”) and the ship speed (LOG), are used to calculate the “true” wind-values via a built-in RS422 interface.
The selection for displaying the “true” or “relative” wind values is done through the mode-key on the front side.


4.3251.xx.001 
     


    




Interface

Meas. value input
   WS
   WD

or
   WD + WS

and
   LOG + Gyro


Other techn.
data see above

4 x RS 422


0...1600 Hz
Thies- synchronous
serial

Serial data telegram
via RS 422

Serial data telegram
acc. to NMEA 0183
(DM)

 

Recorder

       


Continuous Line Recorder
Designed for the continuous recording and the direct reading of wind measuring values.
Instrument as switchpanel- installation housing. Identification of individual channels by different colour pens.








9.3392.10.040
 
9.3393.10.040 
9.3395.10.040 











Number of channels


Electr. input
Accuracy
Print colour
Recording width
Paper advance

Model
Operating voltage
Ambient temp.
Type of protection
Dimensions
Weight

1
2
3
0 ... 20 mA / 0 ... 10 V
class 0.5
blue, red, green
100 mm
20, 60, 120,
240 mm/h
switch-panel-mounting
230 V / 50 Hz
0 ... +50°C
IP 54 or IP 20
144 x 144 x 295 mm
6.2 kg




Recorder Roll
Recording chart in roll format for the above line recorder.
205434 


Roll length


32 m


 
Felt Pen
Spare pens for identification of the different channels for above line recorder.
205433 
205432 
205431 

Colour



blue   ( 1. channel )
red     ( 2. channel )
green ( 3. channel )

 

Software

       


Meteo-Online
The software Meteo-Online is a WINDOWS Program, compatible to WINDOWS 98 / NT / 2000 / ME/XP. It serves for the visualisation and documentation of meteorological measuring values. The visualisation is carried out alternatively in graphical form as diagram and/or with text. The user has the possibility to place the display-elements free on the screen. The documentation can be recorded in hour's- or day's files with selectable averaging periods for the respective parameters. The documentation files are ASCII-files, and can be imported, for example, directly into EXCEL. All THIESinstruments with serial data output can be connected via the serial interface of a PC. According to the number of serial interfaces it is possible to administrate several instruments at the same time. The Client Server Concept offers the possibility of documenting data in the background without active visualisation


9.1700.98.000
 


























Connectable

Wind Interface
Wind Display
Datalogger

US-Anemometer


Meteo comp


Illustration





Wind direction



Wind speed



Time intervals

Thies instruments

4.4070.01.706
4.3250.xx.000
9.1740.xx.x1x

4.3800.xx.xxx
4.3810.xx.xxx

4.3329.00.000 with
9.3229.00.000

numerals
diagram
wind rose
time
date

instantaneous value
variation
mean value, gliding

instantan, value 1 s
mean value, gliding
min. and max. value

1, 2, 10, 30, 60 min.
for mean values


















  9.1700.98.100  Description and data same as above, however with data monitor for checking the incoming measuring values additionally on threshold values or alarm parameters.  

Wind Alarm

       


Wind Alarm Unit 2
Triggers a threshold value contact for a set velocity value. There are two LEDs on the front plate which indicate the operational control and the switching status of the alarm threshold. The delay times, the switching point and the measuring intervals can be set by means of the rotary switch on the front panel.
There is a code switch to set the following wind transmitter models:
    4.3303.22.000
    4.3515.30.000
    4.3515.50.000
    4.3518.00.000
    4.3519.00.000
    4.3520.00.000








44.3241.00.000 
.00.001 
.02.001 
.03.000 






















Operating voltage
230 V / 50 Hz
230 V / 50 Hz
24 V AC/DC
24 V AC/DC
12 V AC/DC


Alarm range
Resolution
Electr. input
Switching point
Switch-on-delay.
Switch-off-delay.


Measuring interval
Relay output

Contact load


Ambient temp.
Operating voltage
Protection
Dimensions
Weight



incl. supply for heating
w/o supply for heating
incl. supply for heating
w/o supply for heating
w/o supply for heating

1 ... 39 m/s
0.1 m/s
see models
selectable in 1 m/s
1 - 9 s resp. 2 – 18 s
1 - 9 resp. 2 - 18 min.
depends on time
intervals
1 s or 2 s selectable
change-over switch,
one-pole
200 W / 24 V DC
100 W / 250 V DC
1000 VA, max. 8 A
-25 - + 55 °C
230 V / 50 Hz
IP 65
200 x 120 x 75 mm
1 kg









Wind Alarm Unit 3
For the display of the current wind speed values and for triggering a threshold value contact. Switches on the front plate for setting the switching point and the switch-on/switchoff- delays.
Suitable wind transmitter
Best.-Nr. 4.3303.22.000




4.3242.01.000 












Measuring range
Electr. input
Display
Contact load


Switching point
Switch-on delay
Switch-off delay.
Operating voltage
Protection
Dimensions
Weight
0 ... 50 m/s
0 ... 1042 Hz
00.0 ... 99.9 m/s
200 W / 24 V DC
100 W / 250 V DC
2000 VA, max. 8 A
0 ... 50 m/s, selectable
0 - 18 s,      in 9 steps
0 - 18 min., in 9 steps
230 V / 50 Hz
IP 65
200 x 120 x 75 mm
1 kg


Wind Alarm Unit 4
For digital display of the current wind speed value. Triggers two threshold value contacts, for example early warning and main alarm. Switches on the front plate for setting the switching points and the switchon/ switch-off-delays. Instrument with integrated power supply unit for the supply of the wind transmitter heating.

Suitable wind transmitter
Best.-Nr. 4.3303.22.000
4.3242.02.000 













Measuring range
Electr. input
Display
Contact load


Switching point

Switch-on delay.


Switch-off delay.


Operating voltage
Protection
Dimensions
Weight

0-50 m/s
0-1042 Hz
00.0-99.9 m/s
200 W / 24 V DC
100 W / 250 V DC
2000 VA, max. 8 A
2 x 0-50 m/s,
selectable
2 x 0-18 s,
in 9 steps
2 x 0-18 min.
in 9 steps
230 V / 50 Hz
IP 65
230 x 300 x 85 mm
2.6 kg



Wind alarm units in combination with wind transmitters
trigger preventive measures to protect wind-endangered objects.

Applications:
cranes bridges
masts greenhouses
louvers and shutters awnings
stages etc.  
   


Instrument Holders

       


Instrument Holder
For field installation of meteorological measuring instruments. Consisting of mast tube, mounting cross, earth pins for ground installation or dowel pins for fundament as well as a staying and earth clamp.


4.3187.11.000 







Length
Diameter of tube
Material
Weight


2.5 m
48 mm
steel, galvanised
ca. 12 kg





Instrument Holder
For the mounting of meteorological measuring instruments in buildings. For wall mounting consists of mast tube, 2 wall clamps and an earth clamp.
4.3187.11.048 
4.3187.11.060 




Diameter of Tube

Length
Tube
Wall clamp
Earth clamp
Weight
48 mm
60 / 48 mm
4 m
Steel, galvanised
Aluminium
Aluminium
approx. 10 kg
Instrument Holder
For the mounting of meteorological measuring instruments in buildings.
For wall mounting consists of mast tube, 1 wall clamp (above), 1 tilting joint (below) and an earth clamp.
4.3187.13.060 




Diameter of tube
Length
Material
   Tube
   Wall clamp
   Tilting joint
   Earth clamp
Weight
60 / 48 mm
4 m

Steel, galvanised
Aluminium
Steel, galvanised
Aluminium
approx. 10 kg

Telescopic Mast for Field Installation

       


Telescopic Mast
For the field installation of meteorological measuring instruments. Mast with staying, base plate and adaptor. The base plate has a tilting mast receptacle.







4.3179.00.000 
4.3180.00.000 
4.3181.00.000 








Length
4 m
6 m
10 m

Material


Top of mast
Inserted length
Staying


Wind stress


Weight
21 kg
29 kg
44 kg

Aluminium,
sea-water-proof
Ø 49 mm
approx. 1.5 m
three-fold (4 m, 6 m)
six-fold (10 m)


max. 60 m/s



Grounding Set
To ground the preceding telescope masts. Consists of a mast ground clamp, a cross-bar, 2m long, and a CU wire Ø 5 mm, 1 m long.


4.3186.00.000
 
4.3186.00.001 
4.3186.00.002 


Suitable for
4 m mast
6 m mast
10 m mast

Weight
Gripping diameter
60mm
80 mm
90 mm

4.5 kg

Telescopic Mast without Staying

       


Telescopic Mast
For the mounting of meteorological measuring instruments. This telescopic mast can be used at a wall or in the open country, in combination with a respective tilting device, without staying.



4.3179.30.080 
4.3180.30.090 
4.3181.30.116 

4.3181.30.132 





Length / Weight
4 m 15 kg
6 m 16 kg
10 m 43 kg

12 m 67 kg

Top of mast
Material

Diameter of tube
80 / 71 mm
90 / 80 / 71 mm
116 / 102 / 90 /
80 / 71 mm
132 / 116 / 102 /
90 / 80 / 71 mm
Ø 71 mm
Aluminium (AlMgSi1)

Tilting Devices

       


Tilting Device
For field mounting on fundament

The tilting device serves as stand for a telescopic mast. Telescopic mast and tilting device are free-standing, and do not need any staying. For maintenance purpose the telescopic mast can be tilted by means of a rope winch (optional accessory).


4.3181.03.080 
.090 
.116 
.132 





Suitable for
4.3179.30.080
4.3180.30.090
4.3181.30.116
4.3181.30.132

Height
Material
Weight







1580 mm
steel, galvanised
60 kg



Tilting Device
For wall mounting

The tilting device serves as wall mounting device for a telescopic mast. For maintenance purpose the telescopic mast can be tilted by means of a rope winch (optional accessory).

4.3181.13.080
 
4.3181.13.090 
4.3181.13.116 
4.3181.13.132 





Suitable for
4.3179.30.080
4.3180.30.090
4.3181.30.116
4.3181.30.132

Material
Weight







steel, galvanised
32 kg

Mast Mounting Clamp
Type: LMB 80/90/116/132

For wall mounting of the telescopic mast.




   
    210363
    210364
    211278
    210368




Suitable for
4.3179.30.080
4.3180.30.090
4.3181.30.116
4.3181.30.132
Diameter


Material
Weight






80 / 90 / 116 /
132 mm
Aluminium
0.5 / 0.7 / 1.3 /
1.5 kg
Mast Ground Clamp LE
Clamp to be mounted at the mast foot for grounding the mast by means of a wire with diameter up to 9 mm.




  
    210457
    210458
    211279
    210460


Suitable for
4.3179.30.080
4.3180.30.090
4.3181.30.116
4.3181.30.132

Material
Weight
Gripping diameter
  80 mm
  90 mm
116 mm
132 mm

aluminium
ca. 0.13 kg

Traverses

       


Traverse
for Classic Wind Transmitters

For mounting the wind speed transmitter and wind direction transmitter jointly onto a mast. The traverse is connected with plug according to the transmitter combinations.








4.3170.00.xxx 
....000 
....001 
....003 











Wind Transmitt.
4.3303.22.000
4.3303.22.000
4.3105.22.000

Material
Tube dimensions


Fixing boring
Horizontal
   Sensor distance
Vertical
   Sensor distance
Total height
Weight

Wind Direc. Transm.
4.3120.22.018
4.3121.32.000
4.3120.22.018

Steel, galvanised
1 1/2" acc. to
DIN 2448
(Ø 48.3 x 2.6 mm)
Ø 50 x 74 mm

0.6 m

0.02 m
0.71 m
6.8 kg





Traverse
for Classic Wind Transmitters

For mounting the wind speed transmitter and wind direction transmitter jointly onto a mast.


4.3173.01.000 

4.3173.01.001 








Fixing boring
Fixing boring

Tube dimensions

Material

Horizontal
   Sensor distance
Vertical
   Sensor distance
Total height
Weight
Ø 50 x 74 mm
Ø 71 x 74 mm

1 1/2" n. DIN 2448
(Ø 48.3 x 2.6 mm)
Aluminium, anodised
(AlMgSi0,5)

0.6 m

0.2 m
0.8 m
3 kg

Traverse
for Wind Transmitters ”First Class“

For mounting the wind speed
transmitter and wind direction
transmitter jointly onto a mast.
4.3174.00.000 





Material

Tube dimensions
Fixing boring
Horizontal
   Sensor distance
Vertical
   Sensor distance
Total height
Weight
Aluminium, anodised
(AlMgSi0,5)
Ø 34 x 4 mm
Ø 50 mm

0.6 m

0.2 m
0.76 m
3 kg

Traverse
for Classic Wind Transmitters

For mounting the wind speed transmitter and wind direction transmitter jointly onto a mast.
4.3172.00.000 





Sensor distance
Vertic. Sensor distance
Total height
Mast clamp
Material
Weight
0.6 m
approx. 400 mm
650 mm
Ø 40-Ø 80 mm
Aluminium (AlMg3)
2.8 kg

Traverse
For Small Wind Transmitters

For mounting the wind transmitter and wind direction transmitter jointly onto a mast.
4.3171.20.000 





Clamping range
Sensor distance
Material
   Traverse


   Gripping clamp
Weight

Ø 30 ... Ø 50 mm
0.5 m

Aluminium, anodised
(AlMgSi0,5)
stainless steel
0.35 kg

Traverse
for Wind Transmitters compact

For mounting the wind speed transmitter and wind direction transmitter jointly onto a mast.

4.3171.30.000 
.31.        





Clamping range

Sensor distance
Material
   Traverse

   Mounting set
Weight
Ø 48 ..... Ø 102 mm
Ø 116 ... Ø 200 mm
0.8 m

Aluminium
(AlMgSi0,5)
stainless steel (V2A)
0.30 kg


Traverse, short
for Wind Transmitters compact

For mounting the wind speed transmitter and wind direction transmitter jointly onto a mast.

4.3171.40.000 
.41.        





Clamping range

Sensor distance
Material
   Traverse

   Mounting set
Weight
Ø 48 ..... Ø 102 mm
Ø 116 ... Ø 200 mm
0.8 m from mast

Aluminium
(AlMgSi0,5)
stainless steel (V2A)
0.30 kg


Lightning Rod / Hangers / Holders / Adaptors

     


Lightning Rod
To be mounted additionally at
the telescopic mast, tube or
traverse. Protects the wind
transmitter against damages
caused by lightning strokes.
Suitable for:
Traverse: 4.3174.00.000
Mast or tube with Ø 48-50 mm
Mast or tube with Ø 48-50 mm
Mast or tube with Ø 71 mm
Traverse: 4.3173.01.001
Traverse: 4.3171.30/31/40/41…









4.3100.98.000 
4.3100.99.000 
4.3100.99.150 
4.3100.99.170 
4.3100.99.001 
506351             


Length





500 mm
560 mm
560 mm
560 mm
400 mm
....
Height





1050 mm
800 mm
1500 mm
1500 mm
1500 mm
560 mm
> Material





Aluminium
Steel,galvanised
Steel,galvanised
Steel,galvanised
Aluminium
Stainless steel
Weight





1.5 kg
2,4 kg
4    kg
4    kg
2   kg
0,34 kg





Hanger, 1 m
The hanger is used for the
lateral mounting of a wind
transmitter, Classic type or
Ultrasonic-Anemometer, onto
a mast.
4.3185.xx.003 
...00....     
...01....     
...02....     







Clamp range
For mast diameter


Tube diameter
Clamp range
Material

Weight




60-132 mm
40-80 mm
48-50 mm
1 m
34 mm
Aluminium
(AlMgSi0,5)
approx. 1.5 kg




Hanger-First Class-1 m
The hanger is used for the lateral mounting of a wind transmitter, First Class type,
onto a mast.
4.3184.01.000 







Clamp range
For mast diameter
Length
Tube diameter
Material

Weight

40-80 mm
1 m
34 mm
Aluminium
(AlMgSi0,5)
approx. 1.5 kg




Holder compact
Serves for mounting the wind transmitter compact onto a mast tube.



506347             






Material
Clamp range
Dimensions
Weight



stainless steel
Ø 35 – 50 mm
80 x 150 mm
0.35 kg



Adaptor
Serves for reducing the diameter of the mast end tube from 71 mm to 50 mm so that Classic wind transmitters or USanemometers can be mounted directly onto the mast top.
211545             
   




Material
Weight




aluminium
1 kg




Adaptor
Serves for reducing the mast diameter to 50 mm diameter for mounting wind transmitters of the classic types or ultrasonic anemometers onto a mast top. The POM (plastic)-model insulates the measuring instrument with the mast.
507936             
508077             
507555             
   
Mast diameter



Diameter

Material
Weight
71 mm
60 mm
50 mm

145 mm high
Ø 110 / 95 / 70 mm
POM
0.9 / 0.7 / 0.4 kg
Adaptor 1"
Serves for reducing a traverse tube diameter from 50 to 34 mm in order to mount a wind transmitter of the first class types.
507620              




Material
Weight


Aluminium (AlMgSi1)
0.5 kg


Adaptor 1"
The adaptor is used to mount wind measuring instruments of the compact-series to a 1"- tube.
506283              




Material
Weight


Aluminium (AlMgSi1)
0.5 kg


Mounting Set compact
Mounting holder with straps for mounting of power supply units, connection boxes compact, and wind interfaces onto masts or tubes.
506614              
506971              
  




Clamping range

Material
Weight



Ø 48-102 mm
Ø 116-200 mm
Stainless steel (V2A)
0.18 kg



Power Supply

       


Power Supply Unit
For the power supply of wind speed transmitters, wind directions transmitters or combined instruments. The outputs are each protected by fuses. The housing is made of plastic fibre.

Suitable for:
Wind transmitter type:
• Compact
• Classic
• First Class
• Ultrasonic 2 D, 1D

 

9.3388.00.000 









Primary
Secondary


Protection
Dimensions
Weight

230 V / 50 Hz / 0.48 A
26 V AC / 3.46 A
24 V AC / 0.5 A
12 V DC / 0.3 A
IP 65
125 x 150 x 125 mm
2.5 kg

Power Supply Unit
For the power supply of wind speed transmitters or wind directions transmitters

The in- and outputs are each protected by fuses. The housing is made of plastic fibre.

Suitable for:
Wind transmitter type:
• Compact
• Classic

9.3388.00.002 
9.3388.00.112 













Primary
Primary
Secondary
Protection
Dimensions
Weight





230 V/50 Hz / 0.091 A
115 V/60 Hz / 0.21 A
24 V AC / 0.83 A
IP 65
125 x 150 x 100 mm
1.2 kg










Power Supply Unit
For the power supply of wind speed transmitters, wind direction transmitters or combined instruments.

With integrated terminal strip for the connection and distribution of the cables.

The in- and outputs are each protected by fuses.

The housing is made of plastic fibre.

Suitable for:
Wind transmitter type:
• Compact
• Classic
• First Class
• Ultrasonic 2 D, 1D, 2D compact

9.3389.10.000 
9.3389.10.010 













Primary voltage
Primary voltage
Secondary voltage



Terminal strip
Housing
Protection housing
Dimensions
Weight





230 V / 50Hz / 0.63 A
115 V / 60Hz / 1.3 A
2 x 24 V AC / 27.5 VA
1 x 24 V AC / 100 VA
1 x 24 V AC / 5 VA
1 x 24 V DC / 2 W
20-pole
plastic fibre
IP 65
300 x 230 x 132 mm
4.2 kg










Connection Box compact 1
For the power supply of wind transmitters, wind direction transmitters or combined instruments.

With integrated over-voltageprotection (varistors) and terminal strip for the connection and distribution of the cables.

Suitable for:
wind transmitter type
• Compact
• Classic
• First Class
• Ultrasonic 1D

Measuring value transmitter
• Clima Sensor
9.3199.00.100 
9.3199.00.110 
















Primary voltage
Primary voltage
Secondary voltage




Terminal strip

Over-voltage-protection
Housing
Protection housing
Dimensions

Weight




230 V / 50 Hz
115 V / 50 Hz
2 x 24 V AC / 27.5 VA
1 x 24 V AC / 75 VA
1 x 24 V DC / 5 W
1 x 24 V DC / 1.5 W
1 x 12 V DC / 2.5 W
For 16
measurement lines
All connections

Aluminium
IP 65
260 x 160 x 90 mm
(B x H x T)
4.5 kg









Connection Box compact
For the power supply of wind transmitters, wind direction transmitters or combined instruments.

With integrated over-voltageprotection (varistors) and terminal strip for the connection and distribution of the cables.

Suitable for:
Wind transmitter type
• Compact
• Classic
• First Class
• Ultrasonic 3D, 2D, 1D,
2D compact

Measuring value transmitter
• Clima Sensor
9.3199.03.100 













Primary voltage
Secondary voltage





Terminal strip

Over-voltage- protection
Housing
Protection housing
Dimensions

Weight

230 V / 50 Hz
1 x 24 V AC / 170 VA
1 x 24 V AC / 20 VA
1 x 24 V AC / 10 VA
1 x 24 V DC / 5 W
1 x 24 V DC / 1.5 W
1 x 12 V DC / 2.5 W
For 16 measurement
lines
All connections

Aluminium
IP 65
202 x 232 x 111 mm
(B x H x T)