Registers the sunshine duration for one entire day. A cut glass sphere focuses the sun’s rays and leave an image line on the strip chart. The length of the image line corresponds to the duration of sunshine. The shipment includes the following strip charts
140 sheets for summer
140 sheets for winter
100 sheets for spring and autumn
North. and southern
hemisphere, latitude
Measuring value
Degree of latitude
Recording period
Dimensions
Weight
25 - 60 °
sunshine duration
adjustable
1 day per strip chart
205 x 185 x 145 mm
5 kg
Recording charts for:
7.1400.10.000
7.1405.10.000
205210 205213
Sunshine Indicator SDE
Instrument to measure the
global radiation and the
sunshine duration.
The threshold of sunshine
duration is stated by the
German Weather Service (DWD)
with 120 W/m2. The sensor
delivers a digital Yes-/
No-information for the sunshine
duration and a voltage as
information for the global
radiation. The measurement
is cos-corrected.
Delivery includes calibration
certificate.
Measuring range
Spectral range
Max. spectr.
sensitivity
Ambient temp.
Linearity
Cos-correction
Absolute error
Signal output
Operating voltage
Sunshine duration
signal
Threshold
Diffusor
Cable
Dimensions
Weight
0 - ca. 1300 W/m2
0.38 mm - 1.1 μm
0.78 μm
-30 °C - +60 °C
< 1 %
error f2 < 3%
< ± 5 %
0 - 5 V (global rad.)
10 V - 24 V DC
yes 4.5 V - 5.0 V
no 0 V - 0.6 V
120 W/m2
PTFE
5 m long
Ø 80 mm, 82 mm high
0.3 kg
Sunshine
Duration - Sensor CSD 1
Instrument to measure the
sunshine duration and direct
radiation.
The sunshine duration is
defined as period, in which the
direct solar radiation exceeds
the threshold of > 120 W/m2.
The sensor sends a digital
Yes/No-information for the
sunshine duration, and a
voltage as information for
the direct radiation.
Delivery includes a test
certificate.
7.1421.00.001
With heating
Sunshine duration
Threshold
Electr. output
Direct Radiation
Meas. range
` Electr. output
Ambient temp.
Operating voltage
Heating voltage
or
Heating voltage
Cable
Dimensions
weight
Brightness Transmitter
The instrument serves for the
acquisition of the daylight
intensity, and is adapted to
the sensitivity of the human
eye. The linearized electrical
output signal can be used for
the control of shading devices,
heating systems, and
irrigation plants.
Accuracy
Spectral range
Half angle
Operating voltage
Protection
Dimensions
Weight
0 - 100 000 lux
0 - 20 000 lux
0 - 5 000 lux
0 - 2 000 lux
0 - 20 mA (600 Ω)
4 - 20 mA (600 Ω)
0 - 10 V (max. 10 mA)
± 3 % of mr.
0.350 - 0.775 μm
± 55 °
24 V AC/DC
IP 65
80 x 82 x 65 mm
0.15 kg
Brightness Transmitter
Measuring instrument for the
acquisition of the daylight
intensity.
The electrical output can
be used for the regulation
of shading devices, heatingand
irrigation plants.
The acquisition is carried out in
the upper part (dome) of the
instrument. The acquisition
angle is ± 90 degrees.
The model with “heating” avoids a possible dewing on
the dome
7.1414.40.002 .102
Without heating
With heating
Measuring range
Electr. Output
Spectral range
Acquisition angle
elevation
azimuth
Accuracy
Operating voltage:
electronics
heating
Protection:
Dimensions:
Weight:
0 - 100 000 lux
0 … 10 V DC
0.350 - 0.820 mm
0.....90°
0...360°
± 2% reference unit
15...28 V DC, 5 mA
24 V AC/DC (± 20 %),
< 300 mA
IP 65
80 x 82 x 112 mm
(w x d x h)
0.15 kg
Brightness Transmitter
Measuring sensor for the
acquisition of the brightness.
It can be used for the regulation
of shading devices, heatingand
irrigation plants in
automatically controlled green
houses or as twilight sensor.
There are two analogue
outputs available: output
1 offers different, selectable
measuring ranges. Output 2 is
used as fixed measuring range,
particularly for the twilight
range. The output signals
can be delivered as voltage
or current.
Pyranometer CM 11
WMO-recommended measured
value transmitter to determine
global radiation. It is also used
as a reference instrument due
to its measurement precision.
Easy to adjust horizontally
owing to its adjustable feet and
a level. The protective label can
be easily removed.
The instrument is “secondary
standard” according to WMO
and ISO 9060.
Delivery includes calibration
certificate.
7.1415.01.000
Measuring range
Sensitivity
Spectral range
Non-linearity
Impedance
Response time
Sensor type
Ambient temp.
Cable
Dimensions
Weight
0 - 1400 W/m2
4 - 6 μV/W/m2
0.305 - 2.8 μm
± 0.6 % < 1000 W/m2
700 - 1500 Ω
1/e 4s ; 99 % 24s
100 Thermocouples
- 40 - + 80 °C
10 m long
Ø 150 x 92 mm
0.85 kg
Pyranometer CM 6B
The instrument can be used
also as Albedometer. Easy to
adjust horizontally owing to its
adjustable feet and a level.
The protective label can be
easily removed.
The instrument is “first class”
according to WMO and ISO
9060.
Delivery includes calibration
certificate.
7.1415.02.000
Measuring range
Sensitivity
Spectral range
Non-linearity
Impedance
Response time
Sensor type
Ambient temp.
Cable
Dimensions
Weight
0 - 1400 W/m2
9 - 15 μV/W/m2
0.305 - 2.8 μm
1.5 % (< 1000 W/m2)
70 - 100 Ω
1/e 5 s ; 99 % 55 s
64 Thermocouples
- 40 - + 80 °C
10 m long
Ø 150 x 92 mm
0.85 kg
Pyranometer CM 3
Measuring value transmitter for
the determination of the global
radiation. The instrument can
be used also as Albedometer.
The instrument is “second
class” according to WMO and
ISO 9060.
Delivery includes calibration
certificate.
7.1415.03.000
Measuring range
Sensitivity
Spectral range
Non-linearity
Impedance
Response time
Sensor type
Ambient temp.
Cable
Dimensions
Weight
0 - 1400 W/m2
10 - 35 μV/W/m2
0.305 - 2.8 μm
2.5 % (< 1000 W/m2)
79 - 200 Ω
18 s at 95 %
64 Thermocouples
- 40 - + 80 °C
5 m long
Ø 55 x 60 mm
0.35 kg
Shadow Ring CM 121
Serves for shading the
Pyranometer from direct solar
radiation. By that, an exact
measurement of the diffuse
sky radiation is possible.
Suitable sensors :
Pyranometer CM 11 or
Pyranometer CM 6B
Remark: Pyranometer not
included in delivery
7.1415.01.121
Material
Height (max.)
Ring outer Ø
Ring width
Ring width /
Ring radius ratio
Cover bracket
Weight
Anodised aluminium
800 mm
620 mm
55 mm
0,185
10.6 °
6 kg
Pyranometer SP-Lite
Electrical measuring
instrument to measure the
global radiation.
The sensor element consists
of a silicium-photodiode; it
delivers a voltage signal in
direct proportion to the
radiation.
Delivery includes calibration
certificate.
Spectral range
Max. spectr.
sensitivity
Cos-correction
Linearity
Abs. error
Diffuser
Dome
Ambient temp.
Operating voltage
for output 10 V
Cable
Dimensions
Weight
0 - 1300 W/m2
0 - 20 mA
4 - 20 mA
0 - 5 V
0 - 10 V
0.4 - 1.1 μm
0.78 μm
error f2 < 3 %
< 1 %
< 10 %
PTFE
PMMA
- 30 - + 60 °C
12 - 24 VDC
14 - 24 VDC
5 m long
Ø 80 x 95 mm
0.3 kg
Pyranometer GSM 10.7
Electrical measuring
instrument to measure
the global radiation.
Spectral range
Max. spectr. sensitivity
Cos - correction
Linearity
Abs. error
Diffuser
Dome
Ambient temp.
Operating voltage
for output 10 V
Cable
Dimensions
Weight
0 - 1300 W/m2
0 - 20 mA
4 - 20 mA
0 - 5 V
0 - 10 V
0.380- 2.8 μm
0.390 – 2.5 μm
error f2 < 3 %
< 1 %
< 10 %
PTFE
optical glass
- 30 - + 60 °C
+12 - +24 V DC
+14 - +24 V DC
5 m long
Ø 80 x 86 mm
0.3 kg
Net Radiation Transmitter
Suitable for measuring
radiation balance consists of
two identical thermocouple
elements. The upper plate
measures global radiation,
the lower one measures the
reflected radiation from the
surface. The interior is dried
by means of silica gel.
The instrument is “first class”
according to WMO Delivery
includes calibration certificate.
Measuring range
Sensitivity approx.
Spectral range
Impedance approx.
Response time
Linearity
Dome
Sensor type
Ambient temp.
Cable
Dimensions
Weight
0 - 1500 W/m2
ca. 15 μV/ W/m2
0.3 - > 30 μm
5 Ω
25 s at 95 %
(0.5 - 1330 Ω/m2)
Lupolene
Thermocouples
- 40 - + 60 °C
10 m long
127 x 50 x 35 mm
0.35 kg
Pyrradiometer
For measurement of the total
radiation balance, globalradiation
and reflected radiation.
The measuring values of the
global and the reflected radiation
are put out separately.
The instrument is “first class”
according to WMO.
Delivery includes calibration
certificate.
Measuring range
Sensitivity approx.
Spectral range
Impedance approx.
Linearity
Response time
Sensor type
Ambient temp.
Cable
Dimensions
Weight
0 - 1500 W/m2
15 μV/W/m2
0.3 - > 60 μm
190 Ω/Sensor
< 2 %
(0.5 - 1330 Ω/m2)
25 s at 95 %
45 s at 99 %
Thermocouples
- 40 - + 60 °C
5 m long
Ø 90 x 88 mm
1.25 kg
Albedometer CM 7B
To measure the short-wave
radiation balance, global
radiation and reflection
radiation.
Albedo could be calculated
from this measured values.
The instrument consists of
two identical Pyrradiometers.
The upper measures the
global radiation, the lower
the reflection radiation of the
ground. The Pyrradiometers
have separate outputs. The
interior is dried by means of
silica gel.
Delivery includes calibration
certificate.
7.1415.25.000
Measuring range
Sensitivity
Spectral range
Impedance
Linearity
Response time
Sensor type
Cable
Dimensions
Weight
0 - 2000 W/m2
9 - 15 μV/W/m2
0.3 - 2.8 μm
70 - 100 Ω
± 1.5 % < 1000 W/m2
1/e 4 s; 55 s at 99%
Thermocouples
10 m long
Ø 150 x 115 mm
1.9 kg
Net Radiometer NR Lite
Instrument for the measurement
of the net radiation, that
means the instrument forms
the difference between the
global radiation from above
(solar radiation and long-wave
atmospheric counter radiation)
and the global radiation from
below (short-wave and longwave
reflection radiation of
the earth)
The output signal is in
proportion to the net radiation,
and can be interpreted as
radiation energy which is
absorbed from the earth’s
surface.
7.1415.01.121
Measuring range
Sensitivity
Spectral range
Response time
Sensor type
Ambient temp.
Cable
Dimensions
Support Arm
Weight
- 200 - + 1500 W/m2
10 μV/ W/ m2
0.2 - 100 μm
20 s
Thermocouple
- 30 - + 70 °C
3 m long
Ø 80 mm
Ø 16 x 400 mm
0.26 kg
UVAB Sensor E 1.1
The sensor acquires the
radiations UV-A and UV-B
independently from each
other.
The measuring results
correspond to the erythemcurve
acc. to DIN 5050. They
give direct information about
the medically and biologically
relevant correlation of these
radiation fields.
The measurement is
cos-corrected.
Delivery includes calibration
certificate.
UV-B
Measuring range
Spectral range
max. sensitivity UV-A
Measuring range
Spectral range
max. sensitivity
Operating voltage
for output 10 V
Ambient temp.
Switch on time
Switch off time
Cos-correction
Linearity
Absolute error
Temp. coeff.
Cable
Dimensions
Weight
0 - 20 mA
4 - 20 mA
0 - 5 V
0 - 10 V
0 - ca. 0.7 W /m2
0.265 - 0.315 μm
0.297 μm
0 - ca. 100 W /m2
0.310 - 0.400 μm
0.335 μm
10 - 24 V DC
14 - 24 V DC
-30°C - + 60°C
< 1 s
< 12 s
error f2 < 1,5 %
< 1%
< ±10 %
< 0.2 % /K
5 m long, connector
Ø 80 x 82 mm
0.3 kg
UVB Sensor E 1.c
Measuring transmitter
for short-wave radiation,
which can cause irreversible
damages of the human skin.
The relative spectral sensitivity
of the sensor is especially
suited to the erythem-curve
acc. to DIN 5050. This sensor
determines exactly the skindamaging
components of the
spectral range.
Delivery includes calibration
certificate.
Measuring range
Spectral range
Max. spectr.
sensitivity
Ambient temp.
Switch on time
Switch off time
Cos-correction
Linearity
Absolute error
Operating voltage
for output 10 V
Cable
Dimensions
Weight
0 - 20 mA
4 - 20 mA
0 - 5 V
0 - 10 V
0 - ca. 0.5 W /m2
0.265 - 0.315 μm
0.297 μm
-30°C - + 60°C
< 1 s
< 12 s
error f2 < 3 %
< 1%
< 10 %
10 - 24 V DC
14 - 24 V DC
5 m long
Ø 42 x 90 mm
0.3 kg
Sensor PAR 5.3
With the PAR-sensor the photochemical
growth processes of
outdoor- and greenhouseplants
can be optimized.
The sensitivity corresponds to
the optimal degree of effect of
chlorophyll. The measuring
results make it possible to
assess reliably the developmental
conditions of the
plants.
Delivery includes calibration
certificat
Measuring range
Spectral range
Max. spektr.
sensitivity
Switch on time
Switch off time
Cos-Correction
Linearity
Abs. error
Ambient temp.
Operating voltage
for output 10 V
Cable
Dimensions
Weight
0 - 20 mA
4 - 20 mA
0 - 5 V
0 - 10 V
0 - 500 W/m2
0.38 - 0.7 μm
0.42 and 0.6 μm
< 1 s
< 12 s
error f2 < 3%
< 1 %
< 10 %
- 30 °C - + 60 °C
10 - 24 V DC
14 - 24 V DC
5 m long
Ø 80 x 95 mm
0.3 kg
Heat Flux Plate
Measures the temperature
balance through a surface.
Consists of 250 Cu-CuNi
thermocouples between
two stainless steel plates.
Delivery includes calibration
certificate.
7.1417.00.000
Sensitivity
Impedance
Accuracy
Time response
Temp. Coeff.
Cable
Dimensions
Weight
200 μV/mW/cm2
20 Ω
±5 %
30 s in air (95 %)
0.2 % / °C
2 m long
48 x 33 x 6 mm
0.22 kg
Heat Flux Plate HFP01
Measures the temperature
balance in a wall or in the
earth.
7.1417.10.000
Measuring range
Sensitivity
Sensor type
Electrical output
Impedance
Time response
Temp. coeff.
Ambient temp.
Cable
Dimension
Weight
+2000 ... - 2000 W/m2
500 μ V/mW/cm2
Thermocouples
mV
2 Ω
± 4 min.
0,1 % / °C
-30 ... +70 °C
5 m long
Ø 80 x 5 mm
0.2 kg
This measuring transducer is
usually connected to radiation
or brightness transmitters. This
allows the control of connected
recording or display instruments.
The electrical input is individually
adjusted to correspond
to that of the transmitter.
The wall mounting case is
designed for mounting to a
plane wall, the PC-board is
designed for insertion into
a 19˝ board rack.
Electrical Input
Ambient temp.
Operating voltage
Protection
Dimensions
Weight
0 - 1300 W/m2
-300 - 1000 W/m2
Wall mounting case
PC-board
0 - 20 mA
4 - 20 mA
0 - 10 V
mV, acc. to the sensor
0 - 40 °C
230 V / 50 Hz
IP 65 (wmc)
200x120x75 mm
(wmc)
170x100x30 mm
(pcb)
0.65 kg resp. 0.25 kg
Preamplifier
The instrument serves to
convert the small measuring
value signals of the radiation
sensor into a standardized
signal, which can be
transmitted also over a
long distance afterwards.
7.1415.00.100
Electrical input
Electrical output
Ambient temp.
Operating voltage
Protection
Cable
Dimensions
Weight
mV, individually
adjusted to the corre-sponded
sensor
0 - 5 V ( 0 -1300W/m2)
-30 °C - +50 °C
6 - 18 V DC
IP 65
3 m long
58 x 35 x 64 mm
0.18 kg
Solar Sensor Amplifier
Instrument to convert the
measuring value signals of the
Pyranometers CM3 or CM11
into a standard output signal.
7.1415.01.400
Electrical input
Electrical output
Ambient temp.
Operating voltage
Protection
Connection
Dimensions
Weight
mV, acc. to the
test certificate
of the sensor.
4… 20mA
- 40 - + 80 °C
12 - 30 V DC
(two-leads-circuit)
IP 65
Cable gland
58 x 35 x 64 mm
0.18 kg
Digital Indicator S for Installation
Flat-section indicator for
connection to available
radiation data transmitters
or measuring transducer.
The measured value is
indicated digitally with red
LED digits.
Designed for installation in
switch panels or front panels.
The background of the indicator
is black to facilitate reading.
7.1044.10.xxx 7.1044.11.xxx .040 .041 .061
Display range
Electrical Input
Resolution
Display
Operating voltage
Model
Protection
Dimensions
Weight
0 - 1300 W/m2
-300 - 1000 W/m2
0 - 20 mA
4 - 20 mA
0 - 10 V
±1 digit
LED, red, 13 mm high
230 V / 50 Hz
Switch panel
installation
IP 20
96 x 48 x 104 mm
0.3 kg
Hanger 1 m
Hangers are used to mount
radiation sensors resp.
brightness transmitters onto
telescopic masts. The extension
is 1 m from the mast.
The outer end has an adaptor
especially designed for the
respective measuring sensor.
4.3185.xx.009 .00. .01. .02.
Clamp range
Tube diameter
Clamp range
Material
Weight
60 - 132 mm
40 - 80 mm
48 - 50 mm
50 mm
for telescopic masts
Aluminium
1.8 kg
Traverse
For mounting two radiation
sensors resp. brightness
transmitters, for example,
onto a mast in connection
with the following adaptors.
4.3171.30.000
Clamp range
Sensor distance
Material
Weight
Ø 48 ... 102 mm
0.8 m
Aluminium / stainless
steel
0.35 kg
Traverse, short
For mounting a radiation
sensor resp. brightness
transmitter, for example,
onto a mast in connection
with the following adaptors.
4.3171.40.000
Clamp range
Sensor distance
Material
Weight
Ø 48 ... 102 mm
0.4 m from mast
Aluminium /
Stainless steel
0.30 kg
Traverse - 0,8 m
For mounting of one Pyranometer
CM 11 / CM 6B and
one Sunshine Duration Sensor
CSD 1 onto a mast.
4.3171.40.002
Clamping range
Sensor distance
Material
Weight
Ø 48 x 102 mm
0.8 / 0.4 m from mast
aluminium / stainless
steel
0.5 kg
Holder >compact<
The holder serves for mounting
the radiation sensor resp.
brightness transmitter
onto a mast tube or for wall
mounting in connection with
the following adaptors.
506347
Material
Clamp range
Dimensions
Weight
Stainless steel
Ø 35 ... 50 mm
80 x 150 mm
0.35 kg
Adaptor
The adaptor serves for mounting
the radiation sensors or
brightness transmitters at the
traverses or holders ›compact‹,
afore mentioned.
Suitable: 7.1415.01/02/03,
7.1415.08/09..., 7.1416.10...,
7.1418.00...