Humidity, Temperature, Pressure Wind Precipitation, Evaporation Radiation Logger; Power Supply; Connection Box Miscellaneous
DATA LOGGERS

Memory Card
TDL 14 Met Station w/ Logger
Protection Roof


Datalogger System

       


Datalogger DL 1/N
The Datalogger is used to store and record the pulse from a Precipitation Transmitter with a Reed-contact. The precipitation is measured by a tipping bucket with a Reed-contact output. These impulses (0.1 mm/ pulse) are stored in the memory together with the date and time. The date, time, name of the station and the store interval are set by two buttons. The stored data can be accessed either direct over the serial interface or it can be read with a Memory (Smart) card. The Datalogger is battery driven and therefore mains independent.









5.1755.10.000
 





















Channel
Measuring input
Storage interval


Storage capacity



Data output

Display



Clock
Operating voltage




Ambient temp.
Protection
Dimensions
Weight

1
Reed contact pulse
1 ... 30 min.,
1 ... 24 Std.
or event depending
64 kB (Ring memory)
32 days at
5 min.-interval
resp. 9289 data sets
RS 232, 9600 Baud
or memory card
date, time, batterycondition,
monthly
sum, station name,
storage interval
Real time clock
4.2 ... 6.5 V
(4 x 1.5 V Mignon cells)
and / or (extern)
7 ... 20 V DC;
6 ... 12 V AC
-10 ... +60 °C
IP 64, with prot. roof
160 x 160 x 90 mm
1.3 kg












Protection Roof
For the protection of the Datalogger
DL 1/N from direct rain. Complete with mast clamp 1 1/2".


5.1755.14.000 





Material
Dimensions
Weight



Aluminium, varnished
160 x 215 x 240 mm
1.3 kg



Read-Out Unit
for Memory Cards
To read and transfer the data stored on the memory (smart) card of the Datalogger DL 1/N directly into a PC. Includes the software for the transfer of the data in ASCII files and to tabulate the values on the screen.

9.1701.10.000 







Input
Printer interface
Power supply
Data cable
Housing
Protection
Dimensions
Weight
Memory Card
Centronics
from PC
1 m long ( to PC )
synthetic
IP 21
120 x 122 x 55 mm
0.28 kg

Memory Card
Portable memory medium for the stored data of the Datalogger DL 1/N.



9.2000.00.005 





Type of memory
Memory capacity
Storage temp.
Ambient temp..
Dimensions
Weight

RAM with Li-Battery
512 k byte
-20 ... +60 °C
-10 ... +55 °C
86 x 54 x 3 mm
ca. 30 g



Modem
To read out the data from measuring systems with Datalogger via serial interface. Delivery with power pack, V.24 cable, phone connecting cable, software and hand books.

210530 





Serial connecting
Model
Wall power supply
Dimensions
Weight

V.24 / RS232 C
table housing
230 V AC (primary)
175 x 170 x 35 mm
ca. 0.7 kg

PC-Cable 2m
For connection from a PC (Laptop) to the Datalogger DL 1/N for direct data read out.

9.1700.20.910 



Cable length
Weight


2 m
0.6 kg